LCS-CHG-01150 to 1000VDC High Voltage Three Phase AC DC Battery Charger
Digital Ultrasonic Generator MPPT Solar Charger Controller PWM Solar Charge Controller Wind Solar Hybrid Controller Grid Connected Inverter AC DC Batter Charger PV Combiner Box VLF High Voltage Generator 12 900V DC Contactor Photovoltaic Parts Soft Starter 150 1000VDC High voltage 3 phase AC DC battery charger LCS CHG 01 150 1000VDC High voltage 3 phase AC DC battery charger is developed specially for 3 phase AC input charging module with high efficiency and a wide range of constant power output, developed specifically for electric vehicle mobile charging stations
Features
1, Power supply module is pluggable, easy to maintain
2, 5 inch colour LCD screen, easy and simple to operate
3, can set the battery evenly voltage, floating voltage, current, and can set manual or automatic mode
4, can be timed charging, powerful protection, overheating, short circuit, overload, overvoltage, undervoltage, etc.
5, soft start charging, soft shutdown to minimize the impact on the battery
6, input has over voltage protection circuit breaker to prevent over voltage burn power module
7, RS485 interface can be selected, the output voltage and current can be controlled through RS485 interface
8, charging pile module ripple current is less than 5%, the charging current impact is small for a variety of current. Category Name Parameter Environmental conditions Operation temperature 40°C ~ +75°C, derating is require when the temperature is above 55°C. Storage temperature 40°C ~ +70°C Relative humidity ≤95%RH, without condensation Cooling mode Forced air cooling Altitude
2,000 m a.s.l., derating is require when the altitude is above 2,000 m a.s.l. Atmospheric pressure 79 kPa ~ 106 kPa AC input Input system Three phases + PE Rated voltage 380 Vac Voltage range 320 Vac ~ 450Vac Maximum current 32A 64A Rated frequency 50Hz/60Hz DC output Voltage range 150~750V Current range
0.1~100A Rated current 50A*2@400V (required for setting of current limiting point,750V is 26.67A) Steady voltage precision <±0.5% Steady current precision ≤±1% (rated range of 20% ~ 100% for output load) Load regulation rate ≤±0.5% Startup overshoot ≤±3% Peak to peak value noise ≤1% (50~750V, 0~20MHz) Power factor and THD Power factor ≥0.95 Full load output power of @20%~50% ≥0.98 Full load output power of @50%~100% ≥0.99 Full load output power, input nominal voltage and frequency of @100% THD ≤5% Full load output power of @50%~100% Efficiency Under Rated input voltage ≥95.2%,@750V,50%~100%
| Category | Name | Parameter |
| Environmental conditions | Operation temperature | -40°C ~ +75°C, derating is require when the temperature is above 55°C. |
| Storage temperature | -40°C ~ +70°C |
| Relative humidity | ≤95%RH, without condensation |
| Cooling mode | Forced air cooling |
| Altitude | 2,000 m a.s.l., derating is require when the altitude is above 2,000 m a.s.l. |
| Atmospheric pressure | 79 kPa ~ 106 kPa |
| AC input | Input system | Three phases + PE |
| Rated voltage | 380 Vac |
| Voltage range | 320 Vac ~ 450Vac |
| Maximum current | 32A-64A |
| Rated frequency | 50Hz/60Hz |
| DC output | Voltage range | 150~750V |
| Current range | 0.1~100A |
| Rated current | 50A*2@400V (required for setting of current limiting point,750V is 26.67A) |
| Steady voltage precision | <±0.5% |
| Steady current precision | ≤±1% (rated range of 20% ~ 100% for output load) |
| Load regulation rate | ≤±0.5% |
| Startup overshoot | ≤±3% |
| Peak-to-peak value noise | ≤1% (50~750V, 0~20MHz) |
| Power factor and THD | Power factor | ≥0.95 Full-load output power of @20%~50% |
| ≥0.98 Full-load output power of @50%~100% |
| ≥0.99 Full-load output power, input nominal voltage and frequency of @100% |
| THD | ≤5% Full-load output power of @50%~100% |
| Efficiency | Under Rated input voltage | ≥95.2%,@750V,50%~100% |
LCS-CHG-02260 to 530Vac Three Phase Smart Battery Charger with CAN
Digital Ultrasonic Generator MPPT Solar Charger Controller PWM Solar Charge Controller Wind Solar Hybrid Controller Grid Connected Inverter AC DC Batter Charger PV Combiner Box VLF High Voltage Generator 12 900V DC Contactor Photovoltaic Parts Soft Starter 260 530Vac 3 phase smart battery charger with CAN LCS CHG 02 high voltage and high power 3 phaes battery charger is developed specially for 3 phase AC input charging module with high efficiency and a wide range of constant power output, developed specifically for electric vehicle mobile charging stations
Features
1, Power supply module is pluggable, easy to maintain
2, 5 inch colour LCD screen, easy and simple to operate
3, can set the battery evenly voltage, floating voltage, current, and can set manual or automatic mode
4, can be timed charging, powerful protection, overheating, short circuit, overload, overvoltage, undervoltage, etc.
5, soft start charging, soft shutdown to minimize the impact on the battery
6, input has over voltage protection circuit breaker to prevent over voltage burn power module
7, RS485 interface can be selected, the output voltage and current can be controlled through RS485 interface
8, charging pile module ripple current is less than 5%, the charging current impact is small for a variety of current. Category Name Parameter Environmental conditions Operation temperature 40°C ~ +75°C, derating is require when the temperature is above 55°C. Storage temperature 40°C ~ +70°C Relative humidity ≤95%RH, without condensation Cooling mode Forced air cooling Altitude
2,000 m a.s.l., derating is require when the altitude is above 2,000 m a.s.l. Atmospheric pressure 79 kPa ~ 106 kPa AC input Input system Three phases + PE Rated voltage 380 Vac Voltage range 320 Vac ~ 530Vac Maximum current 32A Rated frequency 50Hz/60Hz DC output Voltage range 150~750V Current range
0.1~50A Rated current 50A@400V (required for setting of current limiting point,750V is 26.67A) Steady voltage precision <±0.5% Steady current precision ≤±1% (rated range of 20% ~ 100% for output load) Load regulation rate ≤±0.5% Startup overshoot ≤±3% Peak to peak value noise ≤1% (50~750V, 0~20MHz) Power factor and THD Power factor ≥0.95 Full load output power of @20%~50% ≥0.98 Full load output power of @50%~100% ≥0.99 Full load output power, input nominal voltage and frequency of @100% THD ≤5% Full load output power of @50%~100% Efficiency Under Rated input voltage ≥95.2%,@750V,50%~100%
| Category | Name | Parameter |
| Environmental conditions | Operation temperature | -40°C ~ +75°C, derating is require when the temperature is above 55°C. |
| Storage temperature | -40°C ~ +70°C |
| Relative humidity | ≤95%RH, without condensation |
| Cooling mode | Forced air cooling |
| Altitude | 2,000 m a.s.l., derating is require when the altitude is above 2,000 m a.s.l. |
| Atmospheric pressure | 79 kPa ~ 106 kPa |
| AC input | Input system | Three phases + PE |
| Rated voltage | 380 Vac |
| Voltage range | 320 Vac ~ 530Vac |
| Maximum current | 32A |
| Rated frequency | 50Hz/60Hz |
| DC output | Voltage range | 150~750V |
| Current range | 0.1~50A |
| Rated current | 50A@400V (required for setting of current limiting point,750V is 26.67A) |
| Steady voltage precision | <±0.5% |
| Steady current precision | ≤±1% (rated range of 20% ~ 100% for output load) |
| Load regulation rate | ≤±0.5% |
| Startup overshoot | ≤±3% |
| Peak-to-peak value noise | ≤1% (50~750V, 0~20MHz) |
| Power factor and THD | Power factor | ≥0.95 Full-load output power of @20%~50% |
| ≥0.98 Full-load output power of @50%~100% |
| ≥0.99 Full-load output power, input nominal voltage and frequency of @100% |
| THD | ≤5% Full-load output power of @50%~100% |
| Efficiency | Under Rated input voltage | ≥95.2%,@750V,50%~100% |
LCS-CHG-03Three Phase Battery Charger Power Supply
Digital Ultrasonic Generator MPPT Solar Charger Controller PWM Solar Charge Controller Wind Solar Hybrid Controller Grid Connected Inverter AC DC Batter Charger PV Combiner Box VLF High Voltage Generator 12 900V DC Contactor Photovoltaic Parts Soft Starter 3 phase battery charger power supply l Output overvoltage protection To prevent the disastrous accident caused by output overvoltage to electric consumers, there is overvoltage protection circuit in the module. When output overvoltage occurs, the module locks up automatically, the relative module fault indication light is on, the faulty module quits work automatically and doesn’t affect the normal operation of the entire system. l Output current limiting protect The output current cannot increase infinitely. The maximum value of the output current of each module is limited to the rated output current 105%, in this range, the output current value of the module is continuously adjustable. If the load output of the module, the module will play down the output voltage l Output short circuit protection When output short circuit, the module draws the output voltage to 0 immediately, limit the short circuit current below 15%limit current point to protect the module. The module will not be damaged under short circuit state for a long time, and can go back to work automatically after debugging. l Module parallel protection There is parallel protection circuit in each module to ensure that when the fault module quits the system, the normal work of other modules and the system won’t be effect. Over temperature protection Over temperature protection is mainly for protecting large power converters, under normal operating circumstance, the module design leaves enough margin, under special circumstance, when the module detects that the temperature of the radiator is over 90℃, it will shut down automatically to protect itself. When the temperature of radiator get down, the module will restart work automatically. l Output over current protection Because of the limit of the module output power, the output current cannot increase infinitely. In the range, the output current value of the module is continuously adjustable. If overloaded, the module can reduce output voltage automatically to make it not surplus the rated output limit point in order to protect the power components. The over current protection can be resumed automatically.
Technical specification
Model LCS CHG 03 D 230D20NZ 3 230D30NZ 3 230D40NZ 3 110D20NZ 5 AC input Input voltage 380VAC±20% 380VAC±15% Input phase 3 Phase Power factor ≥93% Input frequency 45 to 65Hz DC output Output voltage 190 300VDC (Nominal 220VDC) 95 150VDC (Nominal 110VDC) Default output voltage 234VDC 117VDC Rated output current 10A 20A 30A 40A 20A Max output power 3000W 6000W 9000W 12000W 3000W Output current limit 105% rated output current Efficiency ≥93 Voltage accuracy ±0.5% Current accuracy ±1% Ripple ≤0.2% Load share imbalance ≤±3%
Features
Communication interface CAN/RS485 RS485 Load capability 100% continuous output current Indicators LED indicator for AC mains, rectifier failure; Digit fault code on LCD display, Protection and alarms Input under/over voltage, output under/over voltage, output current limit, over temperature, short circuit protection, phase loss Insulation
2.1kVac input earth
2.1kVac input output
2.1kVac output earth Mechanical Weight (kgs)
4.5kgs
10.5kgs 19kgs 19kgs 5kgs Dimension(H/W/D) 160/67/299.5 218/118/357 303/136/410 303/136/410 195/91/303 (Enclosure) (mm) Dimension (H/W) 178/71 254/124 340/145 340/145
194.5/90.5 (front panel) (mm) Front panel Plastic Environmental Cooling Method Force air cooling Noise(dB) Storage temperature 40/+60℃ working temperature 10/+40℃ Humidity 95% RH non condensing Altitude ≤2000m
| Technical specification |
| Model LCS-CHG-03 | 230D10NZ-D | 230D20NZ-3 | 230D30NZ-3 | 230D40NZ-3 | 110D20NZ-5 |
| AC input |
| Input voltage | 380VAC±20% | 380VAC±15% |
| Input phase | 3-Phase |
| Power factor | ≥93% |
| Input frequency | 45 to 65Hz |
| DC output |
| Output voltage | 190-300VDC (Nominal 220VDC) | 95-150VDC (Nominal 110VDC) |
| Default output voltage | 234VDC | 117VDC |
| Rated output current | 10A | 20A | 30A | 40A | 20A |
| Max output power | 3000W | 6000W | 9000W | 12000W | 3000W |
| Output current limit | 105% rated output current |
| Efficiency | ≥93 |
| Voltage accuracy | ±0.5% |
| Current accuracy | ±1% |
| Ripple | ≤0.2% |
| Load share imbalance | ≤±3% |
| Features |
| Communication interface | CAN/RS485 | RS485 |
| Load capability | 100% continuous output current |
| Indicators | LED indicator for AC mains, rectifier failure; |
| Digit fault code on LCD display, |
| Protection and alarms | Input under/over voltage, output under/over voltage, output current limit, over temperature, short circuit protection, phase loss |
| Insulation | 2.1kVac input-earth |
| 2.1kVac input-output |
| 2.1kVac output-earth |
| Mechanical |
| Weight (kgs) | 4.5kgs | 10.5kgs | 19kgs | 19kgs | 5kgs |
| Dimension(H/W/D) | 160/67/299.5 | 218/118/357 | 303/136/410 | 303/136/410 | 195/91/303 |
| (Enclosure) (mm) |
| Dimension (H/W) | 178/71 | 254/124 | 340/145 | 340/145 | 194.5/90.5 |
| (front panel) (mm) |
| Front panel | Plastic |
| Environmental |
| Cooling Method | Force-air cooling |
| Noise(dB) | |
| Storage temperature | -40/+60℃ |
| working temperature | -10/+40℃ |
| Humidity | 95% RH non-condensing |
| Altitude | ≤2000m |
LCS-CHG-0450 to 750VDC High Power Single Phase Battery Charger
Digital Ultrasonic Generator MPPT Solar Charger Controller PWM Solar Charge Controller Wind Solar Hybrid Controller Grid Connected Inverter AC DC Batter Charger PV Combiner Box VLF High Voltage Generator 12 900V DC Contactor Photovoltaic Parts Soft Starter 50 750VDC High power single phase battery charger LCS CHG 04 high voltage and high power single phaes battery charger is developed specially for single phase AC input charging module with high efficiency and a wide range of constant power output, developed specifically for electric vehicle mobile charging stations
Features
1, Power supply module is pluggable, easy to maintain
2, 5 inch colour LCD screen, easy and simple to operate
3, can set the battery evenly voltage, floating voltage, current, and can set manual or automatic mode
4, can be timed charging, powerful protection, overheating, short circuit, overload, overvoltage, undervoltage, etc.
5, soft start charging, soft shutdown to minimize the impact on the battery
6, input has over voltage protection circuit breaker to prevent over voltage burn power module
7, RS485 interface can be selected, the output voltage and current can be controlled through RS485 interface
8, charging pile module ripple current is less than 5%, the charging current impact is small for a variety of current. Category Name Parameter Environmental conditions Operating temperature 40°C ~ +75°C, derating is require d when the temperature is above 55°C. Storage temperature 40 ℃ ~ +70 ℃ Relative humidity ≤95%RH, No condensation Cooling way Forced air cooling Altitude 2000m, derating is require d when the altitude is above 2000 m Atmospheric pressure 79kPa ~ 106kPa AC input Input phase Single phase L/N or L1/L2 + PE Voltage rage 90 280Vac The maximum static voltage borne under no operation 300Vac Rated voltage 240Vac Maximum current 32A*3 Grid frequency 45Hz~65Hz Rated frequency 50Hz/60Hz DC output Voltage range 50 750Vdc Rated voltage 240VDC Current range 0 ~ 20A*3 Steady voltage precision <±0.5% Steady current precision ≤±1%(rated range of 20% ~ 100% for output load) Load regulation rate ≤±0.5% Power factor and THD Power factor ≥0.95 @20% to 50% of full load output power ≥0.98 @50% to 100% full load output power ≥0.99 @100% full load output power, nominal input voltage and frequency THD ≤5% @50% to 100% of full load output power Efficiency ≥94.5%, @750V, 50% to 100% load current, at rated input voltage
| Category | Name | Parameter |
| Environmental conditions | Operating temperature | -40°C ~ +75°C, derating is require d when the temperature is above 55°C. |
| Storage temperature | -40 ℃ ~ +70 ℃ |
| Relative humidity | ≤95%RH, No condensation |
| Cooling way | Forced air cooling |
| Altitude | 2000m, derating is require d when the altitude is above 2000 m |
| Atmospheric pressure | 79kPa ~ 106kPa |
| AC input | Input phase | Single phase L/N or L1/L2 + PE |
| Voltage rage | 90-280Vac |
| The maximum static voltage borne under no operation | 300Vac |
| Rated voltage | 240Vac |
| Maximum current | 32A*3 |
| Grid frequency | 45Hz~65Hz |
| Rated frequency | 50Hz/60Hz |
| DC output | Voltage range | 50-750Vdc |
| Rated voltage | 240VDC |
| Current range | 0 ~ 20A*3 |
| Steady voltage precision | <±0.5% |
| Steady current precision | ≤±1%(rated range of 20% ~ 100% for output load) |
| Load regulation rate | ≤±0.5% |
| Power factor and THD | Power factor | ≥0.95 @20% to 50% of full load output power |
| ≥0.98 @50% to 100% full load output power |
| ≥0.99 @100% full load output power, nominal input voltage and
frequency |
| THD | ≤5% @50% to 100% of full load output power |
| Efficiency | ≥94.5%, @750V, 50% to 100% load current, at rated input voltage |
LCS-CHG-0550 to 750VDC Large Current Single Phase Lithium Battery Charger
Digital Ultrasonic Generator MPPT Solar Charger Controller PWM Solar Charge Controller Wind Solar Hybrid Controller Grid Connected Inverter AC DC Batter Charger PV Combiner Box VLF High Voltage Generator 12 900V DC Contactor Photovoltaic Parts Soft Starter 50 750VDC large current single phase lithium battery charger LCS CHG 05 high voltage and high power single phaes battery charger is developed specially for single phase AC input charging module with high efficiency and a wide range of constant power output, developed specifically for electric vehicle mobile charging stations
Features
1, Power supply module is pluggable, easy to maintain
2, 5 inch colour LCD screen, easy and simple to operate
3, can set the battery evenly voltage, floating voltage, current, and can set manual or automatic mode
4, can be timed charging, powerful protection, overheating, short circuit, overload, overvoltage, undervoltage, etc.
5, soft start charging, soft shutdown to minimize the impact on the battery
6, input has over voltage protection circuit breaker to prevent over voltage burn power module
7, RS485 interface can be selected, the output voltage and current can be controlled through RS485 interface
8, charging pile module ripple current is less than 5%, the charging current impact is small for a variety of current. Category Name Parameter Environmental conditions Operating temperature 40°C ~ +75°C, derating is require d when the temperature is above 55°C. Storage temperature 40 ℃ ~ +70 ℃ Relative humidity ≤95%RH, No condensation Cooling way Forced air cooling Altitude 2000m, derating is require d when the altitude is above 2000 m Atmospheric pressure 79kPa ~ 106kPa AC input Input phase Single phase L/N or L1/L2 + PE Voltage rage 90 280Vac The maximum static voltage borne under no operation 300Vac Rated voltage 240Vac Maximum current 32A*3 Grid frequency 45Hz~65Hz Rated frequency 50Hz/60Hz DC output Voltage range 50 750Vdc Rated voltage 240VDC Current range 0 ~ 20A*3 Steady voltage precision <±0.5% Steady current precision ≤±1%(rated range of 20% ~ 100% for output load) Load regulation rate ≤±0.5% Power factor and THD Power factor ≥0.95 @20% to 50% of full load output power ≥0.98 @50% to 100% full load output power ≥0.99 @100% full load output power, nominal input voltage and frequency THD ≤5% @50% to 100% of full load output power Efficiency ≥94.5%, @750V, 50% to 100% load current, at rated input voltage
| Category | Name | Parameter |
| Environmental conditions | Operating temperature | -40°C ~ +75°C, derating is require d when the temperature is above 55°C. |
| Storage temperature | -40 ℃ ~ +70 ℃ |
| Relative humidity | ≤95%RH, No condensation |
| Cooling way | Forced air cooling |
| Altitude | 2000m, derating is require d when the altitude is above 2000 m |
| Atmospheric pressure | 79kPa ~ 106kPa |
| AC input | Input phase | Single phase L/N or L1/L2 + PE |
| Voltage rage | 90-280Vac |
| The maximum static voltage borne under no operation | 300Vac |
| Rated voltage | 240Vac |
| Maximum current | 32A*3 |
| Grid frequency | 45Hz~65Hz |
| Rated frequency | 50Hz/60Hz |
| DC output | Voltage range | 50-750Vdc |
| Rated voltage | 240VDC |
| Current range | 0 ~ 20A*3 |
| Steady voltage precision | <±0.5% |
| Steady current precision | ≤±1%(rated range of 20% ~ 100% for output load) |
| Load regulation rate | ≤±0.5% |
| Power factor and THD | Power factor | ≥0.95 @20% to 50% of full load output power |
| ≥0.98 @50% to 100% full load output power |
| ≥0.99 @100% full load output power, nominal input voltage and
frequency |
| THD | ≤5% @50% to 100% of full load output power |
| Efficiency | ≥94.5%, @750V, 50% to 100% load current, at rated input voltage |
LCS-CHG-065 Inch LCD Touch Screen Lithium Battery Smart Charger
Digital Ultrasonic Generator MPPT Solar Charger Controller PWM Solar Charge Controller Wind Solar Hybrid Controller Grid Connected Inverter AC DC Batter Charger PV Combiner Box VLF High Voltage Generator 12 900V DC Contactor Photovoltaic Parts Soft Starter 5" LCD Touch screen lithium battery smart charger Functional details
1. Hot plug Plug technology is applied to the charging module to provide convenience for installation and maintenance. The access of the charging module to the system shall not disturb the output voltage of the system.
2. Advanced current sharing technology Under constant voltage working mode, the charging modules can share current automatically within 10S, with degree of unbalance less than ±0.5A.
3. Control of input limited power Refer to Fig. 1 8 for the relation between the output power and input voltage of the charging module. When the input voltage is within 2 20 Vac ~ 28 0 Vac (return difference is less than 5V), the module can output the maximum power of 7 KW; when the input voltage is within 9 0 Vac ~ 2 20 Vac, the module can still work normally under limited power mode.
4. Control of output constant power When there is a rated input voltage, the output power of the module is 7 KW The charging module
adopts two working modes
1) The module receives monitoring instructions and works in 32A mode or 16A mode (with different power limits). 2) Outputs 50 500V and 500 750V. When there is no required voltage, the power on defaults to work in the low voltage section. When the actual output of the module is higher than 525V, the module automatically switches to the high voltage section. When the demand is lower than 500V, it will automatically switch back to the low voltage section to work. When the output of the module changes from high voltage to low voltage, the output of the module will drop briefly across the switching point; when the output of the module changes from low voltage to high voltage, there is no drop in the output of the module when it crosses the switching point. When the switching point is crossed, the power output is as above Graph curve way.
5. Temperature limited power Under 55°C ambient temperature, the module can output full power of 7 kW; Over 55°C ambient temperature, the module shall be used by derating with the power Linearly . Under 65°C ambient temperature, the allowable output power of the module is 3,500 W. Under 75°C ambient temperature, the output power of the module is reduced to 0.
7. Regulation of output current limiting point The module has stepless current limiting function. Through the external monitoring module, the current limiting point of the module is adjustable in the range of 0~20A. When the output voltage is between 50Vdc ~ 750Vdc When, the current limiting accuracy of the module is ±0.3A.
8. Regulation of output voltage The output voltage of the module can be regulated constantly through the external monitoring module, with regulation range of 50Vdc ~ 750Vdc and minimum regulation step of
0.1 Vdc.
9. Fan control The built in processor of the module can regulate the speed of the fan according to the internal temperature and output current of the module.
10. Protection of input overvoltage/ voltage shortage The input of the module is a single phase AC voltage. When the input voltage is lower than 90Vac or greater than 280Vac, the module will stop working and no output. When an overvoltage or undervoltage alarm occurs, the module will report the alarm information to the monitoring module; when the input voltage returns to the normal range, the alarm disappears and the module recovers Return to normal working condition.
11. Output overvoltage protection Manual intervention is required after overvoltage protection to boot. The software overvoltage protection point can be set through the monitoring module, the setting range is 76Vdc~778Vdc, and the factory default value is 778Vdc. Manual intervention method: The module can be reset through the monitoring module, or the module can be reset by re powering after the AC power failure.
12. Over temperature protection The environmental over temperature protection point is 80°C. When the DC panel has a temperature over 85°C, the module will stop working; when the DC panel has a temperature below 75°C, the module will automatically work again.
13. Protection of internal bus fault When the internal bus voltage of the module is beyond the overvoltage/ voltage shortage protection point, the module will be powered off automatically. At this time, there is no output from the module and the fault indicator light is on.
14. Short circuit protection In case of short circuit of the module, it will be subjected to protective shutdown and the red indicator light of the panel is on, and this condition will be transmitted to the monitor of the “module fault”.
15. Interruption of background communication After module communication interruption, the protection indicator light will flash and the module will be subject to shutdown protection. When the communication is recovered, the protection indicator light recovers to normal state and the module works again.
16. Protection against fan fault In case of module communication interruption over 8S, the module will be subject to shutdown protection, without voltage output and the protection indicator light will flash. After fault removal, the module will work automatically again.
17. Monitoring performance The charging module is equipped with CAN bus. It can also be converted to RS232 via the protocol converter, and the RS485 protocol communicates with the external monitoring module. Category Name Parameter Environmental conditions Operating temperature 40°C ~ +75°C, derating is required when the temperature is above 55°C. Storage temperature 40℃ ~ +70℃ Relative humidity ≤95%RH, No condensation Cooling way Forced air cooling Altitude 2000m, derating is required when the altitude is above 2000 m Atmospheric pressure 79kPa ~ 106kPa AC input Input phase Single phase L/N or L1/L2 + PE Voltage rage 90 280Vac The maximum static voltage borne under no operation 300Vac Rated voltage 220Vac Maximum current 32A Grid frequency 45Hz~65Hz Rated frequency 50Hz/60Hz DC output Voltage range 50Vdc ~ 750Vdc Current range 0 ~ 20A Rated current
9.33A@750V(Set current limit point, current limit point 1.0 is 9A, converted into current limit point according to actual current demand) Steady voltage precision <±0.5% Steady current precision ≤±1%(rated range of 20% ~ 100% for output load) Load regulation rate ≤±0.5% Grid regulation rate ≤±0.1% (testing range is 320V ~ 530V) Startup overshoot ≤±3% Power factor and THD Power factor ≥0.95 Full load output power of @20%~50% ≥0.98 Full load output power of @50%~100% ≥0.99 Full load output power, input nominal voltage and frequency of @100% THD ≤5% Full load output power of @50%~100% Noise index Peak to peak value noise ≤1% (150~750V, 0~20MHz) Others Safety requirements C lassA , Meet the requiremnt of NB/T 33001 1 2010,NB/T 33008 1 2013 Efficiency ≥94.5%, @750V, 50%~100% load current, under rated input voltage Instant impulse current upon startup <20A Temperature Coefficient(1/℃) ≤±0.01% Startup duration (select the startup mode through the monitoring module) Normal startup mode: the time delay from AC power on to module output is ≤ 8s. Output delayed startup: The startup duration can be set through the monitoring module, with default output startup duration of 3~8s. Noise ≤65dB(A) (1m away) Earthing resistance Earthing resistance ≤ 0.1Ω, bearable current ≥ 25A Leakage current Leakage current≤3.5mA Surge protection Meets IEEE C62 41 1991 Class B3 rating, 6kV/3kA (1.2/50μs impulse voltage and 8/20μs inrush current mixed wave) Insulation resistor The insulation resistance of DC part and AC part to housing and the AC part to the DC part shall be ≥ 10MΩ. Insulation strength AC input terminal to the housing 3535V DC voltage 20S clock, no breakdown, no arcing phenomenon, steady state leakage current is less than 1mA; AC input terminal to DC output terminal 3535V DC voltage 20S clock, no breakdown, no arcing phenomenon, steady state leakage current is less than 1mA; DC output terminal to the housing 3535V DC voltage 20S clock, no breakdown, no arcing phenomenon, steady state leakage current is less than 1mA; ROHS R5 Mechanical parameters Size 87Mm (H) ×177.5mm (W) ×385mm (D) Weight ≤15kg
| Category | Name | Parameter |
| Environmental conditions | Operating temperature | -40°C ~ +75°C, derating is required when the temperature is above 55°C. |
| Storage temperature | -40℃ ~ +70℃ |
| Relative humidity | ≤95%RH, No condensation |
| Cooling way | Forced air cooling |
| Altitude | 2000m, derating is required when the altitude is above 2000 m |
| Atmospheric pressure | 79kPa ~ 106kPa |
| AC input | Input phase | Single phase L/N or L1/L2 + PE |
| Voltage rage | 90-280Vac |
| The maximum static voltage borne under no operation | 300Vac |
| Rated voltage | 220Vac |
| Maximum current | 32A |
| Grid frequency | 45Hz~65Hz |
| Rated frequency | 50Hz/60Hz |
| DC output | Voltage range | 50Vdc ~ 750Vdc |
| Current range | 0 ~ 20A |
| Rated current | 9.33A@750V(Set current limit point, current limit point 1.0 is 9A, converted into current limit point according to actual current demand) |
| Steady voltage precision | <±0.5% |
| Steady current precision | ≤±1%(rated range of 20% ~ 100% for output load) |
| Load regulation rate | ≤±0.5% |
| Grid regulation rate | ≤±0.1% (testing range is 320V ~ 530V) |
| Startup overshoot | ≤±3% |
| Power factor and THD | Power factor | ≥0.95 Full-load output power of @20%~50% |
| ≥0.98 Full-load output power of @50%~100% |
| ≥0.99 Full-load output power, input nominal voltage and frequency of @100% |
| THD | ≤5% Full-load output power of @50%~100% |
| Noise index | Peak-to-peak value noise | ≤1% (150~750V, 0~20MHz) |
| Others | Safety requirements | C lassA , Meet the requiremnt of NB/T 33001-1-2010,NB/T 33008-1-2013 |
| Efficiency | ≥94.5%, @750V, 50%~100% load current, under rated input voltage |
| Instant impulse current upon startup | <20A |
| Temperature Coefficient(1/℃) | ≤±0.01% |
| Startup duration (select the startup mode through the monitoring module) | Normal startup mode: the time delay from AC power-on to module output is ≤ 8s. |
| Output delayed startup: The startup duration can be set through the monitoring module, with default output startup duration of 3~8s. |
| Noise | ≤65dB(A) (1m away) |
| Earthing resistance | Earthing resistance ≤ 0.1Ω, bearable current ≥ 25A |
| Leakage current | Leakage current≤3.5mA |
| Surge protection | Meets IEEE C62 41-1991 Class B3 rating, 6kV/3kA (1.2/50μs impulse voltage and 8/20μs inrush current mixed wave) |
| Insulation resistor | The insulation resistance of DC part and AC part to housing and the AC part to the DC part shall be ≥ 10MΩ. |
| Insulation strength | AC input terminal to the housing 3535V DC voltage 20S clock, no breakdown, no arcing phenomenon, steady state leakage current is less than 1mA; AC input terminal to DC output terminal 3535V DC voltage 20S clock, no breakdown, no arcing phenomenon, steady-state leakage current is less than 1mA; DC output terminal to the housing 3535V DC voltage 20S clock, no breakdown, no arcing phenomenon, steady state leakage current is less than 1mA; |
| ROHS | R5 |
| Mechanical parameters | Size | 87Mm (H) ×177.5mm (W) ×385mm (D) |
| Weight | ≤15kg |
LCS-CHG-07Current and Voltage Adjustable Rectifier Charger
Digital Ultrasonic Generator MPPT Solar Charger Controller PWM Solar Charge Controller Wind Solar Hybrid Controller Grid Connected Inverter AC DC Batter Charger PV Combiner Box VLF High Voltage Generator 12 900V DC Contactor Photovoltaic Parts Soft Starter Current and voltage adjustable rectifier charger LCS CHG 07 Current and voltage adjustable rectifier charger is developed specially for single phase AC input charging module with high efficiency and a wide range of constant power output, developed specifically for electric vehicle mobile charging stations Functional details
1. Hot plug Plug technology is applied to the charging module to provide convenience for installation and maintenance. The access of the charging module to the system shall not disturb the output voltage of the system.
2. Advanced current sharing technology Under constant voltage working mode, the charging modules can share current automatically within 10S, with degree of unbalance less than ±0.5A.
3. Control of input limited power Refer to Fig. 1 8 for the relation between the output power and input voltage of the charging module. When the input voltage is within 220 Vac ~ 280 Vac (return difference is less than 5V), the module can output the maximum power of 7 KW; when the input voltage is within 90 Vac ~ 220 Vac, the module can still work normally under limited power mode.
4. Control of output constant power When there is a rated input voltage, the output power of the module is 7 KW The charging module
adopts two working modes
1) The module receives monitoring instructions and works in 32A mode or 16A mode (with different power limits). 2) Outputs 50 500V and 500 750V. When there is no required voltage, the power on defaults to work in the low voltage section. When the actual output of the module is higher than 525V, the module automatically switches to the high voltage section. When the demand is lower than 500V, it will automatically switch back to the low voltage section to work. When the output of the module changes from high voltage to low voltage, the output of the module will drop briefly across the switching point; when the output of the module changes from low voltage to high voltage, there is no drop in the output of the module when it crosses the switching point. When the switching point is crossed, the power output is as above Graph curve way.
5. Temperature limited power Under 55°C ambient temperature, the module can output full power of 7 kW; Over 55°C ambient temperature, the module shall be used by derating with the power Linearly . Under 65°C ambient temperature, the allowable output power of the module is 3,500 W. Under 75°C ambient temperature, the output power of the module is reduced to 0.
7. Regulation of output current limiting point The module has stepless current limiting function. Through the external monitoring module, the current limiting point of the module is adjustable in the range of 0~20A. When the output voltage is between 50Vdc~750Vdc When, the current limiting accuracy of the module is ±0.3A.
8. Regulation of output voltage The output voltage of the module can be regulated constantly through the external monitoring module, with regulation range of 50Vdc ~ 750Vdc and minimum regulation step of 0.1 Vdc.
9. Fan control The built in processor of the module can regulate the speed of the fan according to the internal temperature and output current of the module.
10. Protection of input overvoltage/ voltage shortage The input of the module is a single phase AC voltage. When the input voltage is lower than 90Vac or greater than 280Vac, the module will stop working and no output. When an overvoltage or undervoltage alarm occurs, the module will report the alarm information to the monitoring module; when the input voltage returns to the normal range, the alarm disappears and the module recovers Return to normal working condition.
11. Output overvoltage protection Manual intervention is required after overvoltage protection to boot. The software overvoltage protection point can be set through the monitoring module, the setting range is 76Vdc~778Vdc, and the factory default value is 778Vdc. Manual intervention method: The module can be reset through the monitoring module, or the module can be reset by re powering after the AC power failure.
12. Over temperature protection The environmental over temperature protection point is 80°C. When the DC panel has a temperature over 85°C, the module will stop working; when the DC panel has a temperature below 75°C, the module will automatically work again.
13. Protection of internal bus fault When the internal bus voltage of the module is beyond the overvoltage/ voltage shortage protection point, the module will be powered off automatically. At this time, there is no output from the module and the fault indicator light is on.
14. Short circuit protection In case of short circuit of the module, it will be subjected to protective shutdown and the red indicator light of the panel is on, and this condition will be transmitted to the monitor of the “module fault”.
15. Interruption of background communication After module communication interruption, the protection indicator light will flash and the module will be subject to shutdown protection. When the communication is recovered, the protection indicator light recovers to normal state and the module works again.
16. Protection against fan fault In case of module communication interruption over 8S, the module will be subject to shutdown protection, without voltage output and the protection indicator light will flash. After fault removal, the module will work automatically again.
17. Monitoring performance The charging module is equipped with CAN bus. It can also be converted to RS232 via the protocol converter, and the RS485 protocol communicates with the external monitoring module. Category Name Parameter Environmental conditions Operating temperature 40°C ~ +75°C, derating is required when the temperature is above 55°C. Storage temperature 40℃ ~ +70℃ Relative humidity ≤95%RH, No condensation Cooling way Forced air cooling Altitude 2000m, derating is required when the altitude is above 2000 m Atmospheric pressure 79kPa ~ 106kPa AC input Input phase Single phase L/N or L1/L2 + PE Voltage rage 90 280Vac The maximum static voltage borne under no operation 300Vac Rated voltage 220Vac Maximum current 32A Grid frequency 45Hz~65Hz Rated frequency 50Hz/60Hz DC output Voltage range 50Vdc ~ 750Vdc Current range 0 ~ 20A Rated current
9.33A@750V(Set current limit point, current limit point 1.0 is 9A, converted into current limit point according to actual current demand) Steady voltage precision <±0.5% Steady current precision ≤±1%(rated range of 20% ~ 100% for output load) Load regulation rate ≤±0.5% Grid regulation rate ≤±0.1% (testing range is 320V ~ 530V) Startup overshoot ≤±3% Power factor and THD Power factor ≥0.95 Full load output power of @20%~50% ≥0.98 Full load output power of @50%~100% ≥0.99 Full load output power, input nominal voltage and frequency of @100% THD ≤5% Full load output power of @50%~100% Noise index Peak to peak value noise ≤1% (150~750V, 0~20MHz) Others Safety requirements C lassA , Meet the requiremnt of NB/T 33001 1 2010,NB/T 33008 1 2013 Efficiency ≥94.5%, @750V, 50%~100% load current, under rated input voltage Instant impulse current upon startup <20A Temperature Coefficient(1/℃) ≤±0.01% Startup duration (select the startup mode through the monitoring module) Normal startup mode: the time delay from AC power on to module output is ≤ 8s. Output delayed startup: The startup duration can be set through the monitoring module, with default output startup duration of 3~8s. Noise ≤65dB(A) (1m away) Earthing resistance Earthing resistance ≤ 0.1Ω, bearable current ≥ 25A Leakage current Leakage current≤3.5mA Surge protection Meets IEEE C62 41 1991 Class B3 rating, 6kV/3kA (1.2/50μs impulse voltage and 8/20μs inrush current mixed wave) Insulation resistor The insulation resistance of DC part and AC part to housing and the AC part to the DC part shall be ≥ 10MΩ. Insulation strength AC input terminal to the housing 3535V DC voltage 20S clock, no breakdown, no arcing phenomenon, steady state leakage current is less than 1mA; AC input terminal to DC output terminal 3535V DC voltage 20S clock, no breakdown, no arcing phenomenon, steady state leakage current is less than 1mA; DC output terminal to the housing 3535V DC voltage 20S clock, no breakdown, no arcing phenomenon, steady state leakage current is less than 1mA; ROHS R5 Mechanical parameters Size 87Mm (H) ×177.5mm (W) ×385mm (D) Weight ≤15kg
| Category | Name | Parameter |
| Environmental conditions | Operating temperature | -40°C ~ +75°C, derating is required when the temperature is above 55°C. |
| Storage temperature | -40℃ ~ +70℃ |
| Relative humidity | ≤95%RH, No condensation |
| Cooling way | Forced air cooling |
| Altitude | 2000m, derating is required when the altitude is above 2000 m |
| Atmospheric pressure | 79kPa ~ 106kPa |
| AC input | Input phase | Single phase L/N or L1/L2 + PE |
| Voltage rage | 90-280Vac |
| The maximum static voltage borne under no operation | 300Vac |
| Rated voltage | 220Vac |
| Maximum current | 32A |
| Grid frequency | 45Hz~65Hz |
| Rated frequency | 50Hz/60Hz |
| DC output | Voltage range | 50Vdc ~ 750Vdc |
| Current range | 0 ~ 20A |
| Rated current | 9.33A@750V(Set current limit point, current limit point 1.0 is 9A, converted into current limit point according to actual current demand) |
| Steady voltage precision | <±0.5% |
| Steady current precision | ≤±1%(rated range of 20% ~ 100% for output load) |
| Load regulation rate | ≤±0.5% |
| Grid regulation rate | ≤±0.1% (testing range is 320V ~ 530V) |
| Startup overshoot | ≤±3% |
| Power factor and THD | Power factor | ≥0.95 Full-load output power of @20%~50% |
| ≥0.98 Full-load output power of @50%~100% |
| ≥0.99 Full-load output power, input nominal voltage and frequency of @100% |
| THD | ≤5% Full-load output power of @50%~100% |
| Noise index | Peak-to-peak value noise | ≤1% (150~750V, 0~20MHz) |
| Others | Safety requirements | C lassA , Meet the requiremnt of NB/T 33001-1-2010,NB/T 33008-1-2013 |
| Efficiency | ≥94.5%, @750V, 50%~100% load current, under rated input voltage |
| Instant impulse current upon startup | <20A |
| Temperature Coefficient(1/℃) | ≤±0.01% |
| Startup duration (select the startup mode through the monitoring module) | Normal startup mode: the time delay from AC power-on to module output is ≤ 8s. |
| Output delayed startup: The startup duration can be set through the monitoring module, with default output startup duration of 3~8s. |
| Noise | ≤65dB(A) (1m away) |
| Earthing resistance | Earthing resistance ≤ 0.1Ω, bearable current ≥ 25A |
| Leakage current | Leakage current≤3.5mA |
| Surge protection | Meets IEEE C62 41-1991 Class B3 rating, 6kV/3kA (1.2/50μs impulse voltage and 8/20μs inrush current mixed wave) |
| Insulation resistor | The insulation resistance of DC part and AC part to housing and the AC part to the DC part shall be ≥ 10MΩ. |
| Insulation strength | AC input terminal to the housing 3535V DC voltage 20S clock, no breakdown, no arcing phenomenon, steady state leakage current is less than 1mA; AC input terminal to DC output terminal 3535V DC voltage 20S clock, no breakdown, no arcing phenomenon, steady-state leakage current is less than 1mA; DC output terminal to the housing 3535V DC voltage 20S clock, no breakdown, no arcing phenomenon, steady state leakage current is less than 1mA; |
| ROHS | R5 |
| Mechanical parameters | Size | 87Mm (H) ×177.5mm (W) ×385mm (D) |
| Weight | ≤15kg |
LCS-CHG-08Economical Power Module Power Supply
Digital Ultrasonic Generator MPPT Solar Charger Controller PWM Solar Charge Controller Wind Solar Hybrid Controller Grid Connected Inverter AC DC Batter Charger PV Combiner Box VLF High Voltage Generator 12 900V DC Contactor Photovoltaic Parts Soft Starter Economical power module power supply High frequency switch power supply modules are designed with world leading patent technology “resonant voltage type soft switching power supply technology, feature high efficiency and stability, small size, light weight. Model LCS CHG 08 110X03N 220AC 220X03N 220AC 400X02N 220AC Weight 1KG Dimension 58mm×118mm×187mm(H/W/D) Cooling method Force air cooling AC input voltage 220V±15% DC output voltage 95 130V 190 260V 260 400V DC output current 3A 2A Efficiency ≥90% Voltage stabilization accuracy ±0.5% Ripple ≤±0.2% Noise ≤50dB
Current share imbalance
±5%
| Model LCS-CHG-08 | 110X03N-220AC | 220X03N-220AC | 400X02N-220AC |
| Weight | 1KG |
| Dimension | 58mm×118mm×187mm(H/W/D) |
| Cooling method | Force-air cooling |
| AC input voltage | 220V±15% |
| DC output voltage | 95-130V | 190-260V | 260-400V |
| DC output current | 3A | 2A |
| Efficiency | ≥90% |
| Voltage stabilization accuracy | ±0.5% |
| Ripple | ≤±0.2% |
| Noise | ≤50dB |
| Current share imbalance: | ±5% |
LCS-CHG-09High Voltage and High Power Three Phase Battery Charger
Digital Ultrasonic Generator MPPT Solar Charger Controller PWM Solar Charge Controller Wind Solar Hybrid Controller Grid Connected Inverter AC DC Batter Charger PV Combiner Box VLF High Voltage Generator 12 900V DC Contactor Photovoltaic Parts Soft Starter High voltage and High power 3 phase battery charger LCS CHG 09 high voltage and high power 3 phaes battery charger is developed specially for 3 phase AC input charging module with high efficiency and a wide range of constant power output, developed specifically for electric vehicle mobile charging stations
Features
1, Power supply module is pluggable, easy to maintain
2, 5 inch colour LCD screen, easy and simple to operate
3, can set the battery evenly voltage, floating voltage, current, and can set manual or automatic mode
4, can be timed charging, powerful protection, overheating, short circuit, overload, overvoltage, undervoltage, etc.
5, soft start charging, soft shutdown to minimize the impact on the battery
6, input has over voltage protection circuit breaker to prevent over voltage burn power module
7, RS485 interface can be selected, the output voltage and current can be controlled through RS485 interface
8, charging pile module ripple current is less than 5%, the charging current impact is small for a variety of current.
LCS-CHG-10Single Phase Electric Battery Charger
Digital Ultrasonic Generator MPPT Solar Charger Controller PWM Solar Charge Controller Wind Solar Hybrid Controller Grid Connected Inverter AC DC Batter Charger PV Combiner Box VLF High Voltage Generator 12 900V DC Contactor Photovoltaic Parts Soft Starter Single Phase Battery Charger 110V/220V natural cooling rectifier is the most favorable product with distinctive design. By using radiator instead of fan, realize a high adaptability on operation conditions and high reliability. u Natural cooling u Modular design, N+1 pc(s) backup u Intuitive display by LED screen u High efficiency, up to 94% 95% u Power factor≥0.93 u Load share, imbalance≤3% u Current limit and multi protection function u Hot swappable, convenient maintenance u RS485 communication interface Model Items 230D05ZZ 220AC 230D10ZZ 220AC 110D20ZZ 220AC 110D10ZZ 220AC Output current(A) 5 10 20 10 Power(KW)
1.5
3.0
3.0
1.5 Input voltage range(VAC) Min 187 Typical 220 Max 253 Output Adjustable Voltage rang(VDC) Min 190 95 Typical 220 110 Max 300 150 voltage stabilization ±0.5% Charger efficiency(efficiency) ≥93% Audible Noise max(dB) 50 Storage temperature(℃) Min 40 Typical 25 Max 60 Working Conditions temperature(℃) Min 10 Typical 25 Max 40 uneven current in parallel operation <±3% Start delay (s) 3S 8S Ripple factor ≤0.5% Load grade Continuous working with Grade I(100%) rating output current Automatic current limiting technology The output current cannot increase infinitely. When output current exceed limited current value, a constant current output. The maximum output current value of each module is limited to the rated output. Output overvoltage protection function After output overvoltage occurs(320±5VDC), the module locks up automatically output short circuit protection When the output current get short circuit, the module will protect itself from broken. After the faults get removed, it will restart working automatically. Note:The constant Voltage Stabilization Tolerance does not contain the built in isolating diode's influence。
| Model Items | 230D05ZZ -220AC | 230D10ZZ -220AC | 110D20ZZ -220AC | 110D10ZZ -220AC |
| Output current(A) | 5 | 10 | 20 | 10 |
| Power(KW) | 1.5 | 3.0 | 3.0 | 1.5 |
| Input voltage range(VAC) | Min | 187 |
| Typical | 220 |
| Max | 253 |
| Output Adjustable Voltage rang(VDC) | Min | 190 | 95 |
| Typical | 220 | 110 |
| Max | 300 | 150 |
| voltage stabilization | ±0.5% |
| Charger efficiency(efficiency) | ≥93% |
| Audible Noise max(dB) | 50 |
| Storage temperature(℃) | Min | -40 |
| Typical | 25 |
| Max | 60 |
| Working Conditions temperature(℃) | Min | -10 |
| Typical | 25 |
| Max | 40 |
| uneven current in parallel operation | <±3% |
| Start delay (s) | 3S-8S |
| Ripple factor | ≤0.5% |
| Load grade | Continuous working with Grade I(100%) rating output current |
| Automatic current limiting technology | The output current cannot increase infinitely. When output current exceed limited current value, a constant current output. The maximum output current value of each module is limited to the rated output. |
| Output overvoltage protection function | After output overvoltage occurs(320±5VDC), the module locks up automatically |
| output short circuit protection | When the output current get short circuit, the module will protect itself from broken. After the faults get removed, it will restart working automatically. |
| Note:The constant Voltage Stabilization Tolerance does not contain the built-in isolating diode's influence。 |
LCS-CHG-11High Power High Voltage Intelligent Charging Cabinet
This high power high voltage intelligent charging cabinet accepts single phase 90V to 280VAC input or three phase 260V to 530VAC input, with output voltage ranges of 50V to 750VDC or 150V to 1000VDC. It offers high efficiency, high power density, low harmonics, constant power output and wide voltage output, and suits chargers for lead acid batteries, gel batteries, lithium iron phosphate batteries and fuel cells.
Applications:
1. Large, medium and small electric vehicle charging stations
2. Transport hub areas such as highway service areas, stations and docks
3. Public places such as city residential areas, shopping plazas and power business premises
Product features:
1. Five inch colour LCD touch screen, convenient and simple to operate
2. Pluggable power modules for easy later maintenance
3. Protection circuit breaker switches on input and output for safety and reliability
4. Battery equalizing charge voltage, float charge voltage and charging current can be set
5. Timed charging can be set, with manual and automatic modes
6. Protection functions include overheat, short circuit, overload, over voltage and under voltage