Chargers and Power

Charging, conversion and starting equipment for solar, storage, marine, vehicle and industrial work. Every line below is quoted to your project, with input, output and protection matched to the load it will serve.

Battery Chargers

LCS-CHG-01

150 to 1000VDC High Voltage Three Phase AC DC Battery Charger

Digital Ultrasonic Generator MPPT Solar Charger Controller PWM Solar Charge Controller Wind Solar Hybrid Controller Grid Connected Inverter AC DC Batter Charger PV Combiner Box VLF High Voltage Generator 12 900V DC Contactor Photovoltaic Parts Soft Starter 150 1000VDC High voltage 3 phase AC DC battery charger LCS CHG 01 150 1000VDC High voltage 3 phase AC DC battery charger is developed specially for 3 phase AC input charging module with high efficiency and a wide range of constant power output, developed specifically for electric vehicle mobile charging stations

Features

1, Power supply module is pluggable, easy to maintain

2, 5 inch colour LCD screen, easy and simple to operate

3, can set the battery evenly voltage, floating voltage, current, and can set manual or automatic mode

4, can be timed charging, powerful protection, overheating, short circuit, overload, overvoltage, undervoltage, etc.

5, soft start charging, soft shutdown to minimize the impact on the battery

6, input has over voltage protection circuit breaker to prevent over voltage burn power module

7, RS485 interface can be selected, the output voltage and current can be controlled through RS485 interface

8, charging pile module ripple current is less than 5%, the charging current impact is small for a variety of current. Category Name Parameter Environmental conditions Operation temperature 40°C ~ +75°C, derating is require when the temperature is above 55°C. Storage temperature 40°C ~ +70°C Relative humidity ≤95%RH, without condensation Cooling mode Forced air cooling Altitude

2,000 m a.s.l., derating is require when the altitude is above 2,000 m a.s.l. Atmospheric pressure 79 kPa ~ 106 kPa AC input Input system Three phases + PE Rated voltage 380 Vac Voltage range 320 Vac ~ 450Vac Maximum current 32A 64A Rated frequency 50Hz/60Hz DC output Voltage range 150~750V Current range

0.1~100A Rated current 50A*2@400V (required for setting of current limiting point,750V is 26.67A) Steady voltage precision <±0.5% Steady current precision ≤±1% (rated range of 20% ~ 100% for output load) Load regulation rate ≤±0.5% Startup overshoot ≤±3% Peak to peak value noise ≤1% (50~750V, 0~20MHz) Power factor and THD Power factor ≥0.95 Full load output power of @20%~50% ≥0.98 Full load output power of @50%~100% ≥0.99 Full load output power, input nominal voltage and frequency of @100% THD ≤5% Full load output power of @50%~100% Efficiency Under Rated input voltage ≥95.2%,@750V,50%~100%

CategoryNameParameter
Environmental conditionsOperation temperature-40°C ~ +75°C, derating is require when the temperature is above 55°C.
Storage temperature-40°C ~ +70°C
Relative humidity≤95%RH, without condensation
Cooling modeForced air cooling
Altitude2,000 m a.s.l., derating is require when the altitude is above 2,000 m a.s.l.
Atmospheric pressure79 kPa ~ 106 kPa
AC inputInput systemThree phases + PE
Rated voltage380 Vac
Voltage range320 Vac ~ 450Vac
Maximum current32A-64A
Rated frequency50Hz/60Hz
DC outputVoltage range150~750V
Current range0.1~100A
Rated current50A*2@400V (required for setting of current limiting point,750V is 26.67A)
Steady voltage precision<±0.5%
Steady current precision≤±1% (rated range of 20% ~ 100% for output load)
Load regulation rate≤±0.5%
Startup overshoot≤±3%
Peak-to-peak value noise≤1% (50~750V, 0~20MHz)
Power factor and THDPower factor≥0.95   Full-load output power of @20%~50%
≥0.98   Full-load output power of @50%~100%
≥0.99  Full-load output power, input nominal voltage and frequency of @100%
THD≤5%  Full-load output power of  @50%~100%
EfficiencyUnder Rated input voltage≥95.2%,@750V,50%~100%
150 to 1000VDC High Voltage Three Phase AC DC Battery Charger 150 to 1000VDC High Voltage Three Phase AC DC Battery Charger
LCS-CHG-02

260 to 530Vac Three Phase Smart Battery Charger with CAN

Digital Ultrasonic Generator MPPT Solar Charger Controller PWM Solar Charge Controller Wind Solar Hybrid Controller Grid Connected Inverter AC DC Batter Charger PV Combiner Box VLF High Voltage Generator 12 900V DC Contactor Photovoltaic Parts Soft Starter 260 530Vac 3 phase smart battery charger with CAN LCS CHG 02 high voltage and high power 3 phaes battery charger is developed specially for 3 phase AC input charging module with high efficiency and a wide range of constant power output, developed specifically for electric vehicle mobile charging stations

Features

1, Power supply module is pluggable, easy to maintain

2, 5 inch colour LCD screen, easy and simple to operate

3, can set the battery evenly voltage, floating voltage, current, and can set manual or automatic mode

4, can be timed charging, powerful protection, overheating, short circuit, overload, overvoltage, undervoltage, etc.

5, soft start charging, soft shutdown to minimize the impact on the battery

6, input has over voltage protection circuit breaker to prevent over voltage burn power module

7, RS485 interface can be selected, the output voltage and current can be controlled through RS485 interface

8, charging pile module ripple current is less than 5%, the charging current impact is small for a variety of current. Category Name Parameter Environmental conditions Operation temperature 40°C ~ +75°C, derating is require when the temperature is above 55°C. Storage temperature 40°C ~ +70°C Relative humidity ≤95%RH, without condensation Cooling mode Forced air cooling Altitude

2,000 m a.s.l., derating is require when the altitude is above 2,000 m a.s.l. Atmospheric pressure 79 kPa ~ 106 kPa AC input Input system Three phases + PE Rated voltage 380 Vac Voltage range 320 Vac ~ 530Vac Maximum current 32A Rated frequency 50Hz/60Hz DC output Voltage range 150~750V Current range

0.1~50A Rated current 50A@400V (required for setting of current limiting point,750V is 26.67A) Steady voltage precision <±0.5% Steady current precision ≤±1% (rated range of 20% ~ 100% for output load) Load regulation rate ≤±0.5% Startup overshoot ≤±3% Peak to peak value noise ≤1% (50~750V, 0~20MHz) Power factor and THD Power factor ≥0.95 Full load output power of @20%~50% ≥0.98 Full load output power of @50%~100% ≥0.99 Full load output power, input nominal voltage and frequency of @100% THD ≤5% Full load output power of @50%~100% Efficiency Under Rated input voltage ≥95.2%,@750V,50%~100%

CategoryNameParameter
Environmental conditionsOperation temperature-40°C ~ +75°C, derating is require when the temperature is above 55°C.
Storage temperature-40°C ~ +70°C
Relative humidity≤95%RH, without condensation
Cooling modeForced air cooling
Altitude2,000 m a.s.l., derating is require when the altitude is above 2,000 m a.s.l.
Atmospheric pressure79 kPa ~ 106 kPa
AC inputInput systemThree phases + PE
Rated voltage380 Vac
Voltage range320 Vac ~ 530Vac
Maximum current32A
Rated frequency50Hz/60Hz
DC outputVoltage range150~750V
Current range0.1~50A
Rated current50A@400V (required for setting of current limiting point,750V is 26.67A)
Steady voltage precision<±0.5%
Steady current precision≤±1% (rated range of 20% ~ 100% for output load)
Load regulation rate≤±0.5%
Startup overshoot≤±3%
Peak-to-peak value noise≤1% (50~750V, 0~20MHz)
Power factor and THDPower factor≥0.95   Full-load output power of @20%~50%
≥0.98   Full-load output power of @50%~100%
≥0.99  Full-load output power, input nominal voltage and frequency of @100%
THD≤5%  Full-load output power of  @50%~100%
EfficiencyUnder Rated input voltage≥95.2%,@750V,50%~100%
260 to 530Vac Three Phase Smart Battery Charger with CAN 260 to 530Vac Three Phase Smart Battery Charger with CAN
LCS-CHG-03

Three Phase Battery Charger Power Supply

Digital Ultrasonic Generator MPPT Solar Charger Controller PWM Solar Charge Controller Wind Solar Hybrid Controller Grid Connected Inverter AC DC Batter Charger PV Combiner Box VLF High Voltage Generator 12 900V DC Contactor Photovoltaic Parts Soft Starter 3 phase battery charger power supply l Output overvoltage protection To prevent the disastrous accident caused by output overvoltage to electric consumers, there is overvoltage protection circuit in the module. When output overvoltage occurs, the module locks up automatically, the relative module fault indication light is on, the faulty module quits work automatically and doesn’t affect the normal operation of the entire system. l Output current limiting protect The output current cannot increase infinitely. The maximum value of the output current of each module is limited to the rated output current 105%, in this range, the output current value of the module is continuously adjustable. If the load output of the module, the module will play down the output voltage l Output short circuit protection When output short circuit, the module draws the output voltage to 0 immediately, limit the short circuit current below 15%limit current point to protect the module. The module will not be damaged under short circuit state for a long time, and can go back to work automatically after debugging. l Module parallel protection There is parallel protection circuit in each module to ensure that when the fault module quits the system, the normal work of other modules and the system won’t be effect. Over temperature protection Over temperature protection is mainly for protecting large power converters, under normal operating circumstance, the module design leaves enough margin, under special circumstance, when the module detects that the temperature of the radiator is over 90℃, it will shut down automatically to protect itself. When the temperature of radiator get down, the module will restart work automatically. l Output over current protection Because of the limit of the module output power, the output current cannot increase infinitely. In the range, the output current value of the module is continuously adjustable. If overloaded, the module can reduce output voltage automatically to make it not surplus the rated output limit point in order to protect the power components. The over current protection can be resumed automatically.

Technical specification

Model LCS CHG 03 D 230D20NZ 3 230D30NZ 3 230D40NZ 3 110D20NZ 5 AC input Input voltage 380VAC±20% 380VAC±15% Input phase 3 Phase Power factor ≥93% Input frequency 45 to 65Hz DC output Output voltage 190 300VDC (Nominal 220VDC) 95 150VDC (Nominal 110VDC) Default output voltage 234VDC 117VDC Rated output current 10A 20A 30A 40A 20A Max output power 3000W 6000W 9000W 12000W 3000W Output current limit 105% rated output current Efficiency ≥93 Voltage accuracy ±0.5% Current accuracy ±1% Ripple ≤0.2% Load share imbalance ≤±3%

Features

Communication interface CAN/RS485 RS485 Load capability 100% continuous output current Indicators LED indicator for AC mains, rectifier failure; Digit fault code on LCD display, Protection and alarms Input under/over voltage, output under/over voltage, output current limit, over temperature, short circuit protection, phase loss Insulation

2.1kVac input earth

2.1kVac input output

2.1kVac output earth Mechanical Weight (kgs)

4.5kgs

10.5kgs 19kgs 19kgs 5kgs Dimension(H/W/D) 160/67/299.5 218/118/357 303/136/410 303/136/410 195/91/303 (Enclosure) (mm) Dimension (H/W) 178/71 254/124 340/145 340/145

194.5/90.5 (front panel) (mm) Front panel Plastic Environmental Cooling Method Force air cooling Noise(dB) Storage temperature 40/+60℃ working temperature 10/+40℃ Humidity 95% RH non condensing Altitude ≤2000m

Technical specification
Model  LCS-CHG-03230D10NZ-D230D20NZ-3230D30NZ-3230D40NZ-3110D20NZ-5
AC input
Input voltage380VAC±20%380VAC±15%
Input phase3-Phase
Power factor≥93%
Input frequency45 to 65Hz
DC output
Output voltage190-300VDC (Nominal 220VDC)95-150VDC (Nominal 110VDC)
Default output voltage234VDC117VDC
Rated output current10A20A30A40A20A
Max output power3000W6000W9000W12000W3000W
Output current limit105% rated output current
Efficiency≥93
Voltage accuracy±0.5%
Current accuracy±1%
Ripple≤0.2%
Load share imbalance≤±3%
Features
Communication interfaceCAN/RS485RS485
Load capability100% continuous output current
IndicatorsLED indicator for AC mains, rectifier failure;
Digit fault code on LCD display,
Protection and alarmsInput under/over voltage, output under/over voltage, output current limit, over temperature, short circuit protection, phase loss
Insulation2.1kVac input-earth
2.1kVac input-output
2.1kVac output-earth
Mechanical
Weight (kgs)4.5kgs10.5kgs19kgs19kgs5kgs
Dimension(H/W/D)160/67/299.5218/118/357303/136/410303/136/410195/91/303
(Enclosure) (mm)
Dimension (H/W)178/71254/124340/145340/145194.5/90.5
(front panel) (mm)
Front panelPlastic
Environmental
Cooling MethodForce-air cooling
Noise(dB)
Storage temperature-40/+60℃
working temperature-10/+40℃
Humidity95% RH non-condensing
Altitude≤2000m
LCS-CHG-04

50 to 750VDC High Power Single Phase Battery Charger

Digital Ultrasonic Generator MPPT Solar Charger Controller PWM Solar Charge Controller Wind Solar Hybrid Controller Grid Connected Inverter AC DC Batter Charger PV Combiner Box VLF High Voltage Generator 12 900V DC Contactor Photovoltaic Parts Soft Starter 50 750VDC High power single phase battery charger LCS CHG 04 high voltage and high power single phaes battery charger is developed specially for single phase AC input charging module with high efficiency and a wide range of constant power output, developed specifically for electric vehicle mobile charging stations

Features

1, Power supply module is pluggable, easy to maintain

2, 5 inch colour LCD screen, easy and simple to operate

3, can set the battery evenly voltage, floating voltage, current, and can set manual or automatic mode

4, can be timed charging, powerful protection, overheating, short circuit, overload, overvoltage, undervoltage, etc.

5, soft start charging, soft shutdown to minimize the impact on the battery

6, input has over voltage protection circuit breaker to prevent over voltage burn power module

7, RS485 interface can be selected, the output voltage and current can be controlled through RS485 interface

8, charging pile module ripple current is less than 5%, the charging current impact is small for a variety of current. Category Name Parameter Environmental conditions Operating temperature 40°C ~ +75°C, derating is require d when the temperature is above 55°C. Storage temperature 40 ℃ ~ +70 ℃ Relative humidity ≤95%RH, No condensation Cooling way Forced air cooling Altitude 2000m, derating is require d when the altitude is above 2000 m Atmospheric pressure 79kPa ~ 106kPa AC input Input phase Single phase L/N or L1/L2 + PE Voltage rage 90 280Vac The maximum static voltage borne under no operation 300Vac Rated voltage 240Vac Maximum current 32A*3 Grid frequency 45Hz~65Hz Rated frequency 50Hz/60Hz DC output Voltage range 50 750Vdc Rated voltage 240VDC Current range 0 ~ 20A*3 Steady voltage precision <±0.5% Steady current precision ≤±1%(rated range of 20% ~ 100% for output load) Load regulation rate ≤±0.5% Power factor and THD Power factor ≥0.95 @20% to 50% of full load output power ≥0.98 @50% to 100% full load output power ≥0.99 @100% full load output power, nominal input voltage and frequency THD ≤5% @50% to 100% of full load output power Efficiency ≥94.5%, @750V, 50% to 100% load current, at rated input voltage

CategoryNameParameter
Environmental conditionsOperating temperature-40°C ~ +75°C, derating is require d when the temperature is above 55°C.
Storage temperature-40 ℃ ~ +70 ℃
Relative humidity≤95%RH, No condensation
Cooling wayForced air cooling
Altitude2000m, derating is require d when the altitude is above 2000 m
Atmospheric pressure79kPa ~ 106kPa
AC inputInput phaseSingle phase L/N or L1/L2 + PE
Voltage rage90-280Vac
The maximum static voltage borne under no operation300Vac
Rated voltage240Vac
Maximum current32A*3
Grid frequency45Hz~65Hz
Rated frequency50Hz/60Hz
DC outputVoltage range50-750Vdc
Rated voltage240VDC
Current range0 ~ 20A*3
Steady voltage precision<±0.5%
Steady current precision≤±1%(rated range of 20% ~ 100% for output load)
Load regulation rate≤±0.5%
Power factor and THDPower factor≥0.95 @20% to 50% of full load output power
≥0.98 @50% to 100% full load output power
≥0.99 @100% full load output power, nominal input voltage and  frequency
THD≤5% @50% to 100% of full load output power
Efficiency≥94.5%, @750V, 50% to 100% load current, at rated input voltage
50 to 750VDC High Power Single Phase Battery Charger 50 to 750VDC High Power Single Phase Battery Charger
LCS-CHG-05

50 to 750VDC Large Current Single Phase Lithium Battery Charger

Digital Ultrasonic Generator MPPT Solar Charger Controller PWM Solar Charge Controller Wind Solar Hybrid Controller Grid Connected Inverter AC DC Batter Charger PV Combiner Box VLF High Voltage Generator 12 900V DC Contactor Photovoltaic Parts Soft Starter 50 750VDC large current single phase lithium battery charger LCS CHG 05 high voltage and high power single phaes battery charger is developed specially for single phase AC input charging module with high efficiency and a wide range of constant power output, developed specifically for electric vehicle mobile charging stations

Features

1, Power supply module is pluggable, easy to maintain

2, 5 inch colour LCD screen, easy and simple to operate

3, can set the battery evenly voltage, floating voltage, current, and can set manual or automatic mode

4, can be timed charging, powerful protection, overheating, short circuit, overload, overvoltage, undervoltage, etc.

5, soft start charging, soft shutdown to minimize the impact on the battery

6, input has over voltage protection circuit breaker to prevent over voltage burn power module

7, RS485 interface can be selected, the output voltage and current can be controlled through RS485 interface

8, charging pile module ripple current is less than 5%, the charging current impact is small for a variety of current. Category Name Parameter Environmental conditions Operating temperature 40°C ~ +75°C, derating is require d when the temperature is above 55°C. Storage temperature 40 ℃ ~ +70 ℃ Relative humidity ≤95%RH, No condensation Cooling way Forced air cooling Altitude 2000m, derating is require d when the altitude is above 2000 m Atmospheric pressure 79kPa ~ 106kPa AC input Input phase Single phase L/N or L1/L2 + PE Voltage rage 90 280Vac The maximum static voltage borne under no operation 300Vac Rated voltage 240Vac Maximum current 32A*3 Grid frequency 45Hz~65Hz Rated frequency 50Hz/60Hz DC output Voltage range 50 750Vdc Rated voltage 240VDC Current range 0 ~ 20A*3 Steady voltage precision <±0.5% Steady current precision ≤±1%(rated range of 20% ~ 100% for output load) Load regulation rate ≤±0.5% Power factor and THD Power factor ≥0.95 @20% to 50% of full load output power ≥0.98 @50% to 100% full load output power ≥0.99 @100% full load output power, nominal input voltage and frequency THD ≤5% @50% to 100% of full load output power Efficiency ≥94.5%, @750V, 50% to 100% load current, at rated input voltage

CategoryNameParameter
Environmental conditionsOperating temperature-40°C ~ +75°C, derating is require d when the temperature is above 55°C.
Storage temperature-40 ℃ ~ +70 ℃
Relative humidity≤95%RH, No condensation
Cooling wayForced air cooling
Altitude2000m, derating is require d when the altitude is above 2000 m
Atmospheric pressure79kPa ~ 106kPa
AC inputInput phaseSingle phase L/N or L1/L2 + PE
Voltage rage90-280Vac
The maximum static voltage borne under no operation300Vac
Rated voltage240Vac
Maximum current32A*3
Grid frequency45Hz~65Hz
Rated frequency50Hz/60Hz
DC outputVoltage range50-750Vdc
Rated voltage240VDC
Current range0 ~ 20A*3
Steady voltage precision<±0.5%
Steady current precision≤±1%(rated range of 20% ~ 100% for output load)
Load regulation rate≤±0.5%
Power factor and THDPower factor≥0.95 @20% to 50% of full load output power
≥0.98 @50% to 100% full load output power
≥0.99 @100% full load output power, nominal input voltage and  frequency
THD≤5% @50% to 100% of full load output power
Efficiency≥94.5%, @750V, 50% to 100% load current, at rated input voltage
50 to 750VDC Large Current Single Phase Lithium Battery Charger 50 to 750VDC Large Current Single Phase Lithium Battery Charger
LCS-CHG-06

5 Inch LCD Touch Screen Lithium Battery Smart Charger

Digital Ultrasonic Generator MPPT Solar Charger Controller PWM Solar Charge Controller Wind Solar Hybrid Controller Grid Connected Inverter AC DC Batter Charger PV Combiner Box VLF High Voltage Generator 12 900V DC Contactor Photovoltaic Parts Soft Starter 5" LCD Touch screen lithium battery smart charger Functional details

1. Hot plug Plug technology is applied to the charging module to provide convenience for installation and maintenance. The access of the charging module to the system shall not disturb the output voltage of the system.

2. Advanced current sharing technology Under constant voltage working mode, the charging modules can share current automatically within 10S, with degree of unbalance less than ±0.5A.

3. Control of input limited power Refer to Fig. 1 8 for the relation between the output power and input voltage of the charging module. When the input voltage is within 2 20 Vac ~ 28 0 Vac (return difference is less than 5V), the module can output the maximum power of 7 KW; when the input voltage is within 9 0 Vac ~ 2 20 Vac, the module can still work normally under limited power mode.

4. Control of output constant power When there is a rated input voltage, the output power of the module is 7 KW The charging module

adopts two working modes

1) The module receives monitoring instructions and works in 32A mode or 16A mode (with different power limits). 2) Outputs 50 500V and 500 750V. When there is no required voltage, the power on defaults to work in the low voltage section. When the actual output of the module is higher than 525V, the module automatically switches to the high voltage section. When the demand is lower than 500V, it will automatically switch back to the low voltage section to work. When the output of the module changes from high voltage to low voltage, the output of the module will drop briefly across the switching point; when the output of the module changes from low voltage to high voltage, there is no drop in the output of the module when it crosses the switching point. When the switching point is crossed, the power output is as above Graph curve way.

5. Temperature limited power Under 55°C ambient temperature, the module can output full power of 7 kW; Over 55°C ambient temperature, the module shall be used by derating with the power Linearly . Under 65°C ambient temperature, the allowable output power of the module is 3,500 W. Under 75°C ambient temperature, the output power of the module is reduced to 0.

7. Regulation of output current limiting point The module has stepless current limiting function. Through the external monitoring module, the current limiting point of the module is adjustable in the range of 0~20A. When the output voltage is between 50Vdc ~ 750Vdc When, the current limiting accuracy of the module is ±0.3A.

8. Regulation of output voltage The output voltage of the module can be regulated constantly through the external monitoring module, with regulation range of 50Vdc ~ 750Vdc and minimum regulation step of

0.1 Vdc.

9. Fan control The built in processor of the module can regulate the speed of the fan according to the internal temperature and output current of the module.

10. Protection of input overvoltage/ voltage shortage The input of the module is a single phase AC voltage. When the input voltage is lower than 90Vac or greater than 280Vac, the module will stop working and no output. When an overvoltage or undervoltage alarm occurs, the module will report the alarm information to the monitoring module; when the input voltage returns to the normal range, the alarm disappears and the module recovers Return to normal working condition.

11. Output overvoltage protection Manual intervention is required after overvoltage protection to boot. The software overvoltage protection point can be set through the monitoring module, the setting range is 76Vdc~778Vdc, and the factory default value is 778Vdc. Manual intervention method: The module can be reset through the monitoring module, or the module can be reset by re powering after the AC power failure.

12. Over temperature protection The environmental over temperature protection point is 80°C. When the DC panel has a temperature over 85°C, the module will stop working; when the DC panel has a temperature below 75°C, the module will automatically work again.

13. Protection of internal bus fault When the internal bus voltage of the module is beyond the overvoltage/ voltage shortage protection point, the module will be powered off automatically. At this time, there is no output from the module and the fault indicator light is on.

14. Short circuit protection In case of short circuit of the module, it will be subjected to protective shutdown and the red indicator light of the panel is on, and this condition will be transmitted to the monitor of the “module fault”.

15. Interruption of background communication After module communication interruption, the protection indicator light will flash and the module will be subject to shutdown protection. When the communication is recovered, the protection indicator light recovers to normal state and the module works again.

16. Protection against fan fault In case of module communication interruption over 8S, the module will be subject to shutdown protection, without voltage output and the protection indicator light will flash. After fault removal, the module will work automatically again.

17. Monitoring performance The charging module is equipped with CAN bus. It can also be converted to RS232 via the protocol converter, and the RS485 protocol communicates with the external monitoring module. Category Name Parameter Environmental conditions Operating temperature 40°C ~ +75°C, derating is required when the temperature is above 55°C. Storage temperature 40℃ ~ +70℃ Relative humidity ≤95%RH, No condensation Cooling way Forced air cooling Altitude 2000m, derating is required when the altitude is above 2000 m Atmospheric pressure 79kPa ~ 106kPa AC input Input phase Single phase L/N or L1/L2 + PE Voltage rage 90 280Vac The maximum static voltage borne under no operation 300Vac Rated voltage 220Vac Maximum current 32A Grid frequency 45Hz~65Hz Rated frequency 50Hz/60Hz DC output Voltage range 50Vdc ~ 750Vdc Current range 0 ~ 20A Rated current

9.33A@750V(Set current limit point, current limit point 1.0 is 9A, converted into current limit point according to actual current demand) Steady voltage precision <±0.5% Steady current precision ≤±1%(rated range of 20% ~ 100% for output load) Load regulation rate ≤±0.5% Grid regulation rate ≤±0.1% (testing range is 320V ~ 530V) Startup overshoot ≤±3% Power factor and THD Power factor ≥0.95 Full load output power of @20%~50% ≥0.98 Full load output power of @50%~100% ≥0.99 Full load output power, input nominal voltage and frequency of @100% THD ≤5% Full load output power of @50%~100% Noise index Peak to peak value noise ≤1% (150~750V, 0~20MHz) Others Safety requirements C lassA , Meet the requiremnt of NB/T 33001 1 2010,NB/T 33008 1 2013 Efficiency ≥94.5%, @750V, 50%~100% load current, under rated input voltage Instant impulse current upon startup <20A Temperature Coefficient(1/℃) ≤±0.01% Startup duration (select the startup mode through the monitoring module) Normal startup mode: the time delay from AC power on to module output is ≤ 8s. Output delayed startup: The startup duration can be set through the monitoring module, with default output startup duration of 3~8s. Noise ≤65dB(A) (1m away) Earthing resistance Earthing resistance ≤ 0.1Ω, bearable current ≥ 25A Leakage current Leakage current≤3.5mA Surge protection Meets IEEE C62 41 1991 Class B3 rating, 6kV/3kA (1.2/50μs impulse voltage and 8/20μs inrush current mixed wave) Insulation resistor The insulation resistance of DC part and AC part to housing and the AC part to the DC part shall be ≥ 10MΩ. Insulation strength AC input terminal to the housing 3535V DC voltage 20S clock, no breakdown, no arcing phenomenon, steady state leakage current is less than 1mA; AC input terminal to DC output terminal 3535V DC voltage 20S clock, no breakdown, no arcing phenomenon, steady state leakage current is less than 1mA; DC output terminal to the housing 3535V DC voltage 20S clock, no breakdown, no arcing phenomenon, steady state leakage current is less than 1mA; ROHS R5 Mechanical parameters Size 87Mm (H) ×177.5mm (W) ×385mm (D) Weight ≤15kg

CategoryNameParameter
Environmental conditionsOperating temperature-40°C ~ +75°C, derating is required when the temperature is above 55°C.
Storage temperature-40℃ ~ +70℃
Relative humidity≤95%RH, No condensation
Cooling wayForced air cooling
Altitude2000m, derating is required when the altitude is above 2000 m
Atmospheric pressure79kPa ~ 106kPa
AC inputInput phaseSingle phase L/N or L1/L2 + PE
Voltage rage90-280Vac
The maximum static voltage borne under no operation300Vac
Rated voltage220Vac
Maximum current32A
Grid frequency45Hz~65Hz
Rated frequency50Hz/60Hz
DC outputVoltage range50Vdc ~ 750Vdc
Current range0 ~ 20A
Rated current9.33A@750V(Set current limit point, current limit point 1.0 is 9A, converted into current limit point according to actual current demand)
Steady voltage precision<±0.5%
Steady current precision≤±1%(rated range of 20% ~ 100% for output load)
Load regulation rate≤±0.5%
Grid regulation rate≤±0.1% (testing range is 320V ~ 530V)
Startup overshoot≤±3%
Power factor and THDPower factor≥0.95  Full-load output power of @20%~50%
≥0.98  Full-load output power of @50%~100%
≥0.99  Full-load output power, input nominal voltage and frequency of @100%
THD≤5%  Full-load output power of @50%~100%
Noise indexPeak-to-peak value noise≤1% (150~750V, 0~20MHz)
OthersSafety requirementsC lassA , Meet the requiremnt of  NB/T 33001-1-2010,NB/T 33008-1-2013
Efficiency≥94.5%, @750V, 50%~100% load current, under rated input voltage
Instant impulse current upon startup<20A
Temperature Coefficient(1/℃)≤±0.01%
Startup duration (select the startup mode through the monitoring module)Normal startup mode: the time delay from AC power-on to module output is ≤ 8s.
Output delayed startup: The startup duration can be set through the monitoring module, with default output startup duration of 3~8s.
Noise≤65dB(A) (1m away)
Earthing resistanceEarthing resistance ≤ 0.1Ω, bearable current ≥ 25A
Leakage currentLeakage current≤3.5mA
Surge protectionMeets IEEE C62 41-1991 Class B3 rating, 6kV/3kA (1.2/50μs impulse voltage and 8/20μs inrush current mixed wave)
Insulation resistorThe insulation resistance of DC part and AC part to housing and the AC part to the DC part shall be ≥ 10MΩ.
Insulation strengthAC input terminal to the housing 3535V DC voltage 20S clock, no breakdown, no arcing phenomenon, steady state leakage current is less than 1mA; AC input terminal to DC output terminal 3535V DC voltage 20S clock, no breakdown, no arcing phenomenon, steady-state leakage current is less than 1mA; DC output terminal to the housing 3535V DC voltage 20S clock, no breakdown, no arcing phenomenon, steady state leakage current is less than 1mA;
ROHSR5
Mechanical parametersSize87Mm (H) ×177.5mm (W) ×385mm (D)
Weight≤15kg
5 Inch LCD Touch Screen Lithium Battery Smart Charger 5 Inch LCD Touch Screen Lithium Battery Smart Charger
LCS-CHG-07

Current and Voltage Adjustable Rectifier Charger

Digital Ultrasonic Generator MPPT Solar Charger Controller PWM Solar Charge Controller Wind Solar Hybrid Controller Grid Connected Inverter AC DC Batter Charger PV Combiner Box VLF High Voltage Generator 12 900V DC Contactor Photovoltaic Parts Soft Starter Current and voltage adjustable rectifier charger LCS CHG 07 Current and voltage adjustable rectifier charger is developed specially for single phase AC input charging module with high efficiency and a wide range of constant power output, developed specifically for electric vehicle mobile charging stations Functional details

1. Hot plug Plug technology is applied to the charging module to provide convenience for installation and maintenance. The access of the charging module to the system shall not disturb the output voltage of the system.

2. Advanced current sharing technology Under constant voltage working mode, the charging modules can share current automatically within 10S, with degree of unbalance less than ±0.5A.

3. Control of input limited power Refer to Fig. 1 8 for the relation between the output power and input voltage of the charging module. When the input voltage is within 220 Vac ~ 280 Vac (return difference is less than 5V), the module can output the maximum power of 7 KW; when the input voltage is within 90 Vac ~ 220 Vac, the module can still work normally under limited power mode.

4. Control of output constant power When there is a rated input voltage, the output power of the module is 7 KW The charging module

adopts two working modes

1) The module receives monitoring instructions and works in 32A mode or 16A mode (with different power limits). 2) Outputs 50 500V and 500 750V. When there is no required voltage, the power on defaults to work in the low voltage section. When the actual output of the module is higher than 525V, the module automatically switches to the high voltage section. When the demand is lower than 500V, it will automatically switch back to the low voltage section to work. When the output of the module changes from high voltage to low voltage, the output of the module will drop briefly across the switching point; when the output of the module changes from low voltage to high voltage, there is no drop in the output of the module when it crosses the switching point. When the switching point is crossed, the power output is as above Graph curve way.

5. Temperature limited power Under 55°C ambient temperature, the module can output full power of 7 kW; Over 55°C ambient temperature, the module shall be used by derating with the power Linearly . Under 65°C ambient temperature, the allowable output power of the module is 3,500 W. Under 75°C ambient temperature, the output power of the module is reduced to 0.

7. Regulation of output current limiting point The module has stepless current limiting function. Through the external monitoring module, the current limiting point of the module is adjustable in the range of 0~20A. When the output voltage is between 50Vdc~750Vdc When, the current limiting accuracy of the module is ±0.3A.

8. Regulation of output voltage The output voltage of the module can be regulated constantly through the external monitoring module, with regulation range of 50Vdc ~ 750Vdc and minimum regulation step of 0.1 Vdc.

9. Fan control The built in processor of the module can regulate the speed of the fan according to the internal temperature and output current of the module.

10. Protection of input overvoltage/ voltage shortage The input of the module is a single phase AC voltage. When the input voltage is lower than 90Vac or greater than 280Vac, the module will stop working and no output. When an overvoltage or undervoltage alarm occurs, the module will report the alarm information to the monitoring module; when the input voltage returns to the normal range, the alarm disappears and the module recovers Return to normal working condition.

11. Output overvoltage protection Manual intervention is required after overvoltage protection to boot. The software overvoltage protection point can be set through the monitoring module, the setting range is 76Vdc~778Vdc, and the factory default value is 778Vdc. Manual intervention method: The module can be reset through the monitoring module, or the module can be reset by re powering after the AC power failure.

12. Over temperature protection The environmental over temperature protection point is 80°C. When the DC panel has a temperature over 85°C, the module will stop working; when the DC panel has a temperature below 75°C, the module will automatically work again.

13. Protection of internal bus fault When the internal bus voltage of the module is beyond the overvoltage/ voltage shortage protection point, the module will be powered off automatically. At this time, there is no output from the module and the fault indicator light is on.

14. Short circuit protection In case of short circuit of the module, it will be subjected to protective shutdown and the red indicator light of the panel is on, and this condition will be transmitted to the monitor of the “module fault”.

15. Interruption of background communication After module communication interruption, the protection indicator light will flash and the module will be subject to shutdown protection. When the communication is recovered, the protection indicator light recovers to normal state and the module works again.

16. Protection against fan fault In case of module communication interruption over 8S, the module will be subject to shutdown protection, without voltage output and the protection indicator light will flash. After fault removal, the module will work automatically again.

17. Monitoring performance The charging module is equipped with CAN bus. It can also be converted to RS232 via the protocol converter, and the RS485 protocol communicates with the external monitoring module. Category Name Parameter Environmental conditions Operating temperature 40°C ~ +75°C, derating is required when the temperature is above 55°C. Storage temperature 40℃ ~ +70℃ Relative humidity ≤95%RH, No condensation Cooling way Forced air cooling Altitude 2000m, derating is required when the altitude is above 2000 m Atmospheric pressure 79kPa ~ 106kPa AC input Input phase Single phase L/N or L1/L2 + PE Voltage rage 90 280Vac The maximum static voltage borne under no operation 300Vac Rated voltage 220Vac Maximum current 32A Grid frequency 45Hz~65Hz Rated frequency 50Hz/60Hz DC output Voltage range 50Vdc ~ 750Vdc Current range 0 ~ 20A Rated current

9.33A@750V(Set current limit point, current limit point 1.0 is 9A, converted into current limit point according to actual current demand) Steady voltage precision <±0.5% Steady current precision ≤±1%(rated range of 20% ~ 100% for output load) Load regulation rate ≤±0.5% Grid regulation rate ≤±0.1% (testing range is 320V ~ 530V) Startup overshoot ≤±3% Power factor and THD Power factor ≥0.95 Full load output power of @20%~50% ≥0.98 Full load output power of @50%~100% ≥0.99 Full load output power, input nominal voltage and frequency of @100% THD ≤5% Full load output power of @50%~100% Noise index Peak to peak value noise ≤1% (150~750V, 0~20MHz) Others Safety requirements C lassA , Meet the requiremnt of NB/T 33001 1 2010,NB/T 33008 1 2013 Efficiency ≥94.5%, @750V, 50%~100% load current, under rated input voltage Instant impulse current upon startup <20A Temperature Coefficient(1/℃) ≤±0.01% Startup duration (select the startup mode through the monitoring module) Normal startup mode: the time delay from AC power on to module output is ≤ 8s. Output delayed startup: The startup duration can be set through the monitoring module, with default output startup duration of 3~8s. Noise ≤65dB(A) (1m away) Earthing resistance Earthing resistance ≤ 0.1Ω, bearable current ≥ 25A Leakage current Leakage current≤3.5mA Surge protection Meets IEEE C62 41 1991 Class B3 rating, 6kV/3kA (1.2/50μs impulse voltage and 8/20μs inrush current mixed wave) Insulation resistor The insulation resistance of DC part and AC part to housing and the AC part to the DC part shall be ≥ 10MΩ. Insulation strength AC input terminal to the housing 3535V DC voltage 20S clock, no breakdown, no arcing phenomenon, steady state leakage current is less than 1mA; AC input terminal to DC output terminal 3535V DC voltage 20S clock, no breakdown, no arcing phenomenon, steady state leakage current is less than 1mA; DC output terminal to the housing 3535V DC voltage 20S clock, no breakdown, no arcing phenomenon, steady state leakage current is less than 1mA; ROHS R5 Mechanical parameters Size 87Mm (H) ×177.5mm (W) ×385mm (D) Weight ≤15kg

CategoryNameParameter
Environmental conditionsOperating temperature-40°C ~ +75°C, derating is required when the temperature is above 55°C.
Storage temperature-40℃ ~ +70℃
Relative humidity≤95%RH, No condensation
Cooling wayForced air cooling
Altitude2000m, derating is required when the altitude is above 2000 m
Atmospheric pressure79kPa ~ 106kPa
AC inputInput phaseSingle phase L/N or L1/L2 + PE
Voltage rage90-280Vac
The maximum static voltage borne under no operation300Vac
Rated voltage220Vac
Maximum current32A
Grid frequency45Hz~65Hz
Rated frequency50Hz/60Hz
DC outputVoltage range50Vdc ~ 750Vdc
Current range0 ~ 20A
Rated current9.33A@750V(Set current limit point, current limit point 1.0 is 9A, converted into current limit point according to actual current demand)
Steady voltage precision<±0.5%
Steady current precision≤±1%(rated range of 20% ~ 100% for output load)
Load regulation rate≤±0.5%
Grid regulation rate≤±0.1% (testing range is 320V ~ 530V)
Startup overshoot≤±3%
Power factor and THDPower factor≥0.95  Full-load output power of @20%~50%
≥0.98  Full-load output power of @50%~100%
≥0.99  Full-load output power, input nominal voltage and frequency of @100%
THD≤5%  Full-load output power of @50%~100%
Noise indexPeak-to-peak value noise≤1% (150~750V, 0~20MHz)
OthersSafety requirementsC lassA , Meet the requiremnt of  NB/T 33001-1-2010,NB/T 33008-1-2013
Efficiency≥94.5%, @750V, 50%~100% load current, under rated input voltage
Instant impulse current upon startup<20A
Temperature Coefficient(1/℃)≤±0.01%
Startup duration (select the startup mode through the monitoring module)Normal startup mode: the time delay from AC power-on to module output is ≤ 8s.
Output delayed startup: The startup duration can be set through the monitoring module, with default output startup duration of 3~8s.
Noise≤65dB(A) (1m away)
Earthing resistanceEarthing resistance ≤ 0.1Ω, bearable current ≥ 25A
Leakage currentLeakage current≤3.5mA
Surge protectionMeets IEEE C62 41-1991 Class B3 rating, 6kV/3kA (1.2/50μs impulse voltage and 8/20μs inrush current mixed wave)
Insulation resistorThe insulation resistance of DC part and AC part to housing and the AC part to the DC part shall be ≥ 10MΩ.
Insulation strengthAC input terminal to the housing 3535V DC voltage 20S clock, no breakdown, no arcing phenomenon, steady state leakage current is less than 1mA; AC input terminal to DC output terminal 3535V DC voltage 20S clock, no breakdown, no arcing phenomenon, steady-state leakage current is less than 1mA; DC output terminal to the housing 3535V DC voltage 20S clock, no breakdown, no arcing phenomenon, steady state leakage current is less than 1mA;
ROHSR5
Mechanical parametersSize87Mm (H) ×177.5mm (W) ×385mm (D)
Weight≤15kg
Current and Voltage Adjustable Rectifier Charger Current and Voltage Adjustable Rectifier Charger
LCS-CHG-08

Economical Power Module Power Supply

Digital Ultrasonic Generator MPPT Solar Charger Controller PWM Solar Charge Controller Wind Solar Hybrid Controller Grid Connected Inverter AC DC Batter Charger PV Combiner Box VLF High Voltage Generator 12 900V DC Contactor Photovoltaic Parts Soft Starter Economical power module power supply High frequency switch power supply modules are designed with world leading patent technology “resonant voltage type soft switching power supply technology, feature high efficiency and stability, small size, light weight. Model LCS CHG 08 110X03N 220AC 220X03N 220AC 400X02N 220AC Weight 1KG Dimension 58mm×118mm×187mm(H/W/D) Cooling method Force air cooling AC input voltage 220V±15% DC output voltage 95 130V 190 260V 260 400V DC output current 3A 2A Efficiency ≥90% Voltage stabilization accuracy ±0.5% Ripple ≤±0.2% Noise ≤50dB

Current share imbalance

±5%

Model  LCS-CHG-08110X03N-220AC220X03N-220AC400X02N-220AC
Weight1KG
Dimension58mm×118mm×187mm(H/W/D)
Cooling methodForce-air cooling
AC input voltage220V±15%
DC output voltage95-130V190-260V260-400V
DC output current3A2A
Efficiency≥90%
Voltage stabilization accuracy±0.5%
Ripple≤±0.2%
Noise≤50dB
Current share imbalance:±5%
Economical Power Module Power Supply
LCS-CHG-09

High Voltage and High Power Three Phase Battery Charger

Digital Ultrasonic Generator MPPT Solar Charger Controller PWM Solar Charge Controller Wind Solar Hybrid Controller Grid Connected Inverter AC DC Batter Charger PV Combiner Box VLF High Voltage Generator 12 900V DC Contactor Photovoltaic Parts Soft Starter High voltage and High power 3 phase battery charger LCS CHG 09 high voltage and high power 3 phaes battery charger is developed specially for 3 phase AC input charging module with high efficiency and a wide range of constant power output, developed specifically for electric vehicle mobile charging stations

Features

1, Power supply module is pluggable, easy to maintain

2, 5 inch colour LCD screen, easy and simple to operate

3, can set the battery evenly voltage, floating voltage, current, and can set manual or automatic mode

4, can be timed charging, powerful protection, overheating, short circuit, overload, overvoltage, undervoltage, etc.

5, soft start charging, soft shutdown to minimize the impact on the battery

6, input has over voltage protection circuit breaker to prevent over voltage burn power module

7, RS485 interface can be selected, the output voltage and current can be controlled through RS485 interface

8, charging pile module ripple current is less than 5%, the charging current impact is small for a variety of current.

LCS-CHG-10

Single Phase Electric Battery Charger

Digital Ultrasonic Generator MPPT Solar Charger Controller PWM Solar Charge Controller Wind Solar Hybrid Controller Grid Connected Inverter AC DC Batter Charger PV Combiner Box VLF High Voltage Generator 12 900V DC Contactor Photovoltaic Parts Soft Starter Single Phase Battery Charger 110V/220V natural cooling rectifier is the most favorable product with distinctive design. By using radiator instead of fan, realize a high adaptability on operation conditions and high reliability. u Natural cooling u Modular design, N+1 pc(s) backup u Intuitive display by LED screen u High efficiency, up to 94% 95% u Power factor≥0.93 u Load share, imbalance≤3% u Current limit and multi protection function u Hot swappable, convenient maintenance u RS485 communication interface Model Items 230D05ZZ 220AC 230D10ZZ 220AC 110D20ZZ 220AC 110D10ZZ 220AC Output current(A) 5 10 20 10 Power(KW)

1.5

3.0

3.0

1.5 Input voltage range(VAC) Min 187 Typical 220 Max 253 Output Adjustable Voltage rang(VDC) Min 190 95 Typical 220 110 Max 300 150 voltage stabilization ±0.5% Charger efficiency(efficiency) ≥93% Audible Noise max(dB) 50 Storage temperature(℃) Min 40 Typical 25 Max 60 Working Conditions temperature(℃) Min 10 Typical 25 Max 40 uneven current in parallel operation <±3% Start delay (s) 3S 8S Ripple factor ≤0.5% Load grade Continuous working with Grade I(100%) rating output current Automatic current limiting technology The output current cannot increase infinitely. When output current exceed limited current value, a constant current output. The maximum output current value of each module is limited to the rated output. Output overvoltage protection function After output overvoltage occurs(320±5VDC), the module locks up automatically output short circuit protection When the output current get short circuit, the module will protect itself from broken. After the faults get removed, it will restart working automatically. Note:The constant Voltage Stabilization Tolerance does not contain the built in isolating diode's influence。

Model Items230D05ZZ -220AC230D10ZZ -220AC110D20ZZ -220AC110D10ZZ -220AC
Output current(A)5102010
Power(KW)1.53.03.01.5
Input voltage range(VAC)Min187
Typical220
Max253
Output Adjustable Voltage rang(VDC)Min19095
Typical220110
Max300150
voltage stabilization±0.5%
Charger efficiency(efficiency)≥93%
Audible Noise max(dB)50
Storage temperature(℃)Min-40
Typical25
Max60
Working Conditions temperature(℃)Min-10
Typical25
Max40
uneven current  in parallel operation<±3%
Start delay (s)3S-8S
Ripple factor≤0.5%
Load gradeContinuous working with Grade I(100%) rating output current
Automatic current limiting technologyThe output current cannot increase infinitely. When output current exceed limited current value, a constant current output. The maximum output current value of each module is limited to the rated output.
Output overvoltage protection functionAfter output overvoltage occurs(320±5VDC), the module locks up automatically
output short circuit protectionWhen the output current get short circuit, the module will protect itself from broken. After the faults get removed, it will restart working automatically.
Note:The constant Voltage Stabilization Tolerance does not contain the built-in isolating diode's influence。
Single Phase Electric Battery Charger
LCS-CHG-11

High Power High Voltage Intelligent Charging Cabinet

This high power high voltage intelligent charging cabinet accepts single phase 90V to 280VAC input or three phase 260V to 530VAC input, with output voltage ranges of 50V to 750VDC or 150V to 1000VDC. It offers high efficiency, high power density, low harmonics, constant power output and wide voltage output, and suits chargers for lead acid batteries, gel batteries, lithium iron phosphate batteries and fuel cells.

Applications:

1. Large, medium and small electric vehicle charging stations

2. Transport hub areas such as highway service areas, stations and docks

3. Public places such as city residential areas, shopping plazas and power business premises

Product features:

1. Five inch colour LCD touch screen, convenient and simple to operate

2. Pluggable power modules for easy later maintenance

3. Protection circuit breaker switches on input and output for safety and reliability

4. Battery equalizing charge voltage, float charge voltage and charging current can be set

5. Timed charging can be set, with manual and automatic modes

6. Protection functions include overheat, short circuit, overload, over voltage and under voltage

Marine Inverter Power

LCS-MPS-01

Marine Inverter Power Supply

This marine inverter power supply is designed for ships where generator voltage and frequency fluctuate widely and load equipment cannot work normally. The voltage stabilizing and frequency stabilizing supply regulates poor quality power and outputs a high quality, reliable stabilized voltage and frequency supply, avoiding harm to load equipment from large voltage and frequency fluctuation and waveform distortion.

Main parameters of the marine inverter power supply:

1. Input voltage: single phase 130V to 300VAC, three phase 260V to 500VAC, or DC input

2. Input frequency: 35Hz to 70Hz

3. Output voltage: 220V or 380VAC plus or minus 3 percent

4. Output frequency: 50Hz plus or minus 0.01 percent

5. Conversion efficiency: 92 percent or more

6. Dynamic response: 20ms or less

7. Waveform distortion: 3 percent or less

8. Sixth generation IPM module, DSP28335 control chip, isolation transformer output and good stability, with over voltage, over current, short circuit and overheat warnings, 32 bit microprocessor control, and LCD plus LED alarm indication.

9. Power range 5KW to 50KW can be customized, with CCS classification society recognition.

IP20 wall mounted or drawer type and IP45 waterproof cabinet versions are shown in the product photos of the marine family on this page.

LCS-MPS-02

10KW Single Phase and Three Phase Marine Isolated Inverter Power Supply

This 10KW single phase and three phase marine isolated inverter power supply is designed for ships where generator voltage and frequency fluctuate widely and load equipment cannot work normally. The voltage stabilizing and frequency stabilizing supply regulates poor quality power and outputs a high quality, reliable stabilized supply, avoiding harm to load equipment from large voltage and frequency fluctuation and waveform distortion.

Main parameters of the marine isolated inverter power supply:

1. Input voltage: single phase 130V to 300VAC, three phase 260V to 500VAC, or 100V to 800VDC DC range input

2. Input frequency: 35Hz to 70Hz

3. Output voltage: 220V or 380VAC plus or minus 3 percent

4. Output frequency: 50Hz plus or minus 0.01 percent

5. Conversion efficiency: 92 percent or more

6. Dynamic response: 20ms or less

7. Waveform distortion: 3 percent or less

8. Sixth generation IPM module, DSP28335 control chip, isolation transformer output and good stability, with over voltage, over current, short circuit and overheat warnings, 32 bit microprocessor control, and LCD plus LED alarm indication.

9. CCS classification society recognition obtained.

Versions include 3KW to 15KW IP20 wall mounted or drawer type units and IP45 waterproof cabinet units.

LCS-MPS-03

Rack Mount Marine Inverter 8KW and 10KW

This rack mount marine inverter converts DC power to AC power with a pure sine wave output, complete protection functions, high whole unit efficiency and low no load loss. It provides effective power supply assurance for areas with difficult transport and harsh environments such as mountain areas, pastoral areas, border defence and islands. The design is user friendly with a generous appearance, convenient operation, intuitive LCD indication, stable work, no noise and low pollution. The AC output suits most industrial and household appliances including power tools, motors, water pumps, lathes, air conditioners, compressors, refrigerators, mixers, washing machines, televisions and fans.

Performance features:

1. Sixth generation IPM module with stable performance and full protection including short circuit, overload and over temperature protection, with a service life of more than 15 years.

2. Dual mode start selection set through the LCD screen, with reduced voltage start and variable frequency start, so the inverter capacity does not need to be enlarged for motor and inductive loads.

3. The output frequency can be set by the user, for example 30Hz to control motor speed.

4. The DC input voltage range can be set through the LCD screen, including over voltage point, under voltage point and recovery points, for flexible use with batteries and PV modules.

5. Pure sine wave output with fast transient response under 50ms, low waveform distortion, high inverter efficiency and stable output voltage.

6. Low frequency isolation transformer fully isolates the AC bus from the DC bus.

7. LCD display showing DC input voltage, output frequency, phase voltage, phase current, mains bypass voltage, output energy in KWH, time, temperature and faults.

8. SVPWM space vector algorithm with high conversion efficiency, high instant power and low no load loss, with conversion efficiency above 93 percent.

9. The inverter can also work without a battery, saving battery and controller cost, with wide DC input ranges of 100V to 400V, 200V to 500V or 480V to 850V using solar power.

10. Low input ripple current, suitable for fuel cells, lithium batteries, lithium iron phosphate batteries, gel batteries, lead acid batteries, wind turbine rectifiers, water turbines and other DC power inputs.

11. Optional functions include RS485 communication, mains bypass, built in solar charge controller, built in mains charger and diesel generator start.

12. Custom builds are available to customer requirements.

ModelLCS-MPS-03LCS-MPS-03
IsolationLow frequency transformer
DC inputRated voltage(VDC)120V192V192V240V
Rated current(A)67A42A52A42A
AC outputRated power (KW)8KW10KW
Output waveformPure sine wave
Output rated voltage220V±3%380VAC±3%220V±3%380VAC±3%
Output frequency50Hz±0.05Hz
Output phasesSingle phase two wireThree phase four wireSingle phase two wireThree phase four wire
Output rated current(A)36A12A (phase current)45.5A15A (phase current)
Power factor(PF)1
Overload capacity150%, 10s
Inverter efficiency>93%
Waveform distortion rate(THD)
Dynamic response(load0~100%)5%,≤50ms
DisplayLCD
Operating modeContinuous operation
Insulation strength2000Vac, 1 minute
ProtectionOperating temperature and humidity range-25~+55℃
Relative humidity0~90%,no condensation
ProtectionInput reverse connection, undervoltage and overvoltage protection, output overload, short circuit and overheat protection
Cooling methodFan
Short circuit protectionNo automatic recovery, restart required
Working environmentNoise (dB,1m)≤50dB
Protection ratingIP20(indoor)
Altitude(m)≤2000
Mechanical dimensionsVertical(D x W x H)480x680x300mm
Weight (kg)88Kg110Kg
CE StandardEN60950-1:2006+A11:2009, EN61000-6-4:2007+A1:2001, EN61000-6-2:2005, EN61000-3-12:2005, EN61000-3-11:2000

Vehicle Mounted Inverter Power

LCS-VPS-01

Rack Mount Vehicle Mounted Low Frequency Inverter Power Supply 5KW and 6KW

Performance features:

1. Sixth generation IPM module with stable performance and full protection including short circuit, overload and over temperature protection, with a service life of more than 15 years.

2. Dual mode start selection set through the LCD screen, with reduced voltage start and variable frequency start, so the inverter capacity does not need to be enlarged for motor and inductive loads.

3. The output frequency can be set by the user, for example 30Hz to control motor speed.

4. The DC input voltage range can be set through the LCD screen, including over voltage point, under voltage point and recovery points, for flexible use with batteries and PV modules.

5. Pure sine wave output with fast transient response under 50ms, low waveform distortion, high inverter efficiency and stable output voltage.

6. Low frequency isolation transformer fully isolates the AC bus from the DC bus.

7. LCD display showing DC input voltage, output frequency, phase voltage, phase current, mains bypass voltage, output energy in KWH, time, temperature and faults.

8. SVPWM space vector algorithm with high conversion efficiency, high instant power and low no load loss, with conversion efficiency above 93 percent.

9. The inverter can also work without a battery, saving battery and controller cost, with wide DC input ranges of 100V to 400V, 200V to 500V or 480V to 850V using solar power.

10. Low input ripple current, suitable for fuel cells, lithium batteries, lithium iron phosphate batteries, gel batteries, lead acid batteries, wind turbine rectifiers, water turbines and other DC power inputs.

11. Optional functions include RS485 communication, mains bypass, built in solar charge controller, built in mains charger and diesel generator start.

12. Custom builds are available to customer requirements.

ModelLCS-VPS-01LCS-VPS-01
DC inputInput rated voltage(VDC)96V192V96V192V
Input rated current(A)52A26A62.5A31A
AC outputRated output power (KW)5KW6KW
Output waveformPure sine wave
Output rated voltage220VAC ±3%380VAC±3%220VAC ±3%380VAC±3%
Output frequency50Hz/60Hz±0.05Hz
Output rated current(A)23A13A27A16A
Power factor(PF)0.99
Overload capacity150%, 10s
Inverter efficiency≥94%
Waveform distortion rate(THD)
Crest factor (CF)3:1
DisplayLCD
Insulation strength(Input and Output)2500Vac, 1 minute
Operating temperature and humidity range-15~+55℃
Relative humidity0~90%,no condensation
ProtectionInput reverse, undervoltage and overvoltage protection, output overload, short circuit and overheat protection
Cooling methodFan,heatsink
Noise
Protection ratingIP20(indoor)
Altitude(m)≤2000
Dimensions L x W x H (mm)482x605x267mm(Single phase)/480*680*300mm(Three phase)
CE StandardEN60950-1:2006+A11:2009, EN61000-6-4:2007+A1:2001, EN61000-6-2:2005, EN61000-3-12:2005, EN61000-3-11:2000
LCS-VPS-02

Sine Wave Vehicle Mounted Inverter 20KW and 25KW

Performance features:

1. Sixth generation IPM module with stable performance and full protection including short circuit, overload and over temperature protection, with a service life of more than 15 years.

2. Dual mode start selection set through the LCD screen, with reduced voltage start and variable frequency start, so the inverter capacity does not need to be enlarged for motor and inductive loads.

3. The output frequency can be set by the user, for example 30Hz to control motor speed.

4. The DC input voltage range can be set through the LCD screen, including over voltage point, under voltage point and recovery points, for flexible use with batteries and PV modules.

5. Pure sine wave output with fast transient response under 50ms, low waveform distortion, high inverter efficiency and stable output voltage.

6. Low frequency isolation transformer fully isolates the AC bus from the DC bus.

7. LCD display showing DC input voltage, output frequency, phase voltage, phase current, mains bypass voltage, output energy in KWH, time, temperature and faults.

8. SVPWM space vector algorithm with high conversion efficiency, high instant power and low no load loss, with conversion efficiency above 93 percent.

9. The inverter can also work without a battery, saving battery and controller cost, with wide DC input ranges of 100V to 400V, 200V to 500V or 480V to 850V using solar power.

10. Low input ripple current, suitable for fuel cells, lithium batteries, lithium iron phosphate batteries, gel batteries, lead acid batteries, wind turbine rectifiers, water turbines and other DC power inputs.

11. Optional functions include RS485 communication, mains bypass, built in solar charge controller, built in mains charger and diesel generator start.

12. Custom builds are available to customer requirements.

ModelLCS-VPS-02
IsolationLow frequency transformer
DC inputRated voltage(VDC)220V360V
Rated current(A)113A70A
AC outputRated power (KW)25KW
Output waveformPure sine wave
Output rated voltage220V±3%380VAC±3%
Output frequency50Hz±0.05Hz
Output phasesSingle phase two wireThree phase four wire
Output rated current(A)113A38A (phase current)
Power factor(PF)1
Overload capacity150%, 10s
Inverter efficiency>93%
Waveform distortion rate(THD)<3%(linearload)< p="">
Dynamic response(load0~100%)5%,≤50ms
DisplayLCD
Operating modeContinuous operation
Insulation strength2000Vac, 1 minute
ProtectionOperating temperature and humidity range-25~+55℃
Relative humidity0~90%,no condensation
ProtectionInput reverse connection, undervoltage and overvoltage protection, output overload, short circuit and overheat protection
Cooling methodFan
Short circuit protectionNo automatic recovery, restart required
Working environmentNoise (dB,1m)≤50dB
Protection ratingIP20(indoor)
Altitude(m)≤2000
Mechanical dimensionsVertical(D x W x H)800x550x650mm
Weight (kg)190Kg
CE StandardEN60950-1:2006+A11:2009, EN61000-6-4:2007+A1:2001, EN61000-6-2:2005, EN61000-3-12:2005, EN61000-3-11:2000
LCS-VPS-03

New Energy Engineering Vehicle Mounted Inverter 30KW and 35KW

Performance features:

1. Sixth generation IPM module with stable performance and full protection including short circuit, overload and over temperature protection, with a service life of more than 15 years.

2. Dual mode start selection set through the LCD screen, with reduced voltage start and variable frequency start, so the inverter capacity does not need to be enlarged for motor and inductive loads.

3. The output frequency can be set by the user, for example 30Hz to control motor speed.

4. The DC input voltage range can be set through the LCD screen, including over voltage point, under voltage point and recovery points, for flexible use with batteries and PV modules.

5. Pure sine wave output with fast transient response under 50ms, low waveform distortion, high inverter efficiency and stable output voltage.

6. Low frequency isolation transformer fully isolates the AC bus from the DC bus.

7. LCD display showing DC input voltage, output frequency, phase voltage, phase current, mains bypass voltage, output energy in KWH, time, temperature and faults.

8. SVPWM space vector algorithm with high conversion efficiency, high instant power and low no load loss, with conversion efficiency above 93 percent.

9. The inverter can also work without a battery, saving battery and controller cost, with wide DC input ranges of 100V to 400V, 200V to 500V or 480V to 850V using solar power.

10. Low input ripple current, suitable for fuel cells, lithium batteries, lithium iron phosphate batteries, gel batteries, lead acid batteries, wind turbine rectifiers, water turbines and other DC power inputs.

11. Optional functions include RS485 communication, mains bypass, built in solar charge controller, built in mains charger and diesel generator start.

12. Custom builds are available to customer requirements.

ModelLCS-VPS-03
IsolationLow frequency transformer
DC inputRated voltage(VDC)220V360V
Rated current(A)136A83A
AC outputRated power (KW)30KW
Output waveformPure sine wave
Output rated voltage220V±3%380VAC±3%
Output frequency50Hz±0.05Hz
Output phasesSingle phase two wireThree phase four wire
Output rated current(A)136A45A (phase current)
Power factor(PF)1
Overload capacity150%, 10s
Inverter efficiency>93%
Waveform distortion rate(THD)<3%(linearload)< p="">
Dynamic response(load0~100%)5%,≤50ms
DisplayLCD
Operating modeContinuous operation
Insulation strength2000Vac, 1 minute
ProtectionOperating temperature and humidity range-25~+55℃
Relative humidity0~90%,no condensation
ProtectionInput reverse connection, undervoltage and overvoltage protection, output overload, short circuit and overheat protection
Cooling methodFan
Short circuit protectionNo automatic recovery, restart required
Working environmentNoise (dB,1m)≤50dB
Protection ratingIP20(indoor)
Altitude(m)≤2000
Mechanical dimensionsVertical(D x W x H)800x550x650mm
Weight (kg)190Kg
CE StandardEN60950-1:2006+A11:2009, EN61000-6-4:2007+A1:2001, EN61000-6-2:2005, EN61000-3-12:2005, EN61000-3-11:2000
LCS-VPS-04

Vehicle Mounted Inverter Power Supply for CT Machines

This vehicle mounted inverter power supply was developed and designed to customer requirements with small volume and light weight, mainly for vehicle mounted CT machines. Vehicle mounted CT machines are designed for mobile physical examination work outside the vehicle base. This supply outputs a stable 380VAC 50Hz pure sine wave, can conveniently charge mobile phones in the field, and avoids the influence of excessive external power supply voltage drop on vehicle equipment. It is compact and light, takes little space in the vehicle and is easy to carry.

Main features:

1. Good stability and high vibration resistance

2. Rack mount structure with small dimensions

3. Digital display for convenient data viewing

4. Pluggable structure for convenient later maintenance

5. Custom builds are available to customer requirements

Vehicle Mounted Inverter Power Supply for CT Machines Vehicle Mounted Inverter Power Supply for CT Machines
LCS-VPS-05

High Power High Voltage Sine Wave Vehicle Mounted Inverter

This high power high voltage sine wave vehicle mounted inverter was developed and designed to customer requirements with small volume and light weight, for vehicle mounted mobile power supply design. It outputs a stable 220V or 380VAC 50Hz pure sine wave, can conveniently charge mobile phones in the field, and avoids the influence of excessive external power supply voltage drop on vehicle equipment. It is compact and light, takes little space in the vehicle and is easy to carry.

Main features:

1. Good stability and high vibration resistance

2. Rack mount structure with small dimensions

3. Digital display for convenient data viewing

4. Pluggable structure for convenient later maintenance

5. Custom builds are available to customer requirements

High Power High Voltage Sine Wave Vehicle Mounted Inverter High Power High Voltage Sine Wave Vehicle Mounted Inverter
LCS-VPS-06

Locomotive and Armoured Vehicle DC to AC Inverter Power Supply

This DC to AC inverter power supply is customized to customer requirements with a horizontal channel steel mounting method for use on armoured vehicles, locomotives, trains and outdoor rescue vehicles. Customer drawings and samples are welcome.

Locomotive and Armoured Vehicle DC to AC Inverter Power Supply Locomotive and Armoured Vehicle DC to AC Inverter Power Supply

Phase Converters

LCS-CNV-01

Three Phase 415V 50Hz to Three Phase 220VAC 60Hz Converter 100KW

Digital Ultrasonic Generator MPPT Solar Charger Controller PWM Solar Charge Controller Wind Solar Hybrid Controller Grid Connected Inverter AC DC Batter Charger PV Combiner Box VLF High Voltage Generator 12 900V DC Contactor Photovoltaic Parts Soft Starter LCS CNV 01 3 phase 415V 50HZ to 3 phase 220VAC 60HZ converter LCS CNV 01 Power phase converter, adopted AC DC AC circuit structure and SVPWM modulation control technology, which can convert ordinary single phase power to industrial three phase power. Two phase to three phase ,3 phase to 3 phase and so on.After through LCS CNV 01 power phase converter power conversion, the output is standard pure sine wave, the harmonic distortion rate (THD) is less than 2%, totally meet the national standards power quality, applicable to all types of load.

Technical Features

1) Using the sixth generation efficient IPM intelligent module from Japanese Mitsubishi, high efficiency and stable performance. It with powerful protection function, the protection for short circuit, over load, over temperature is more safe and reliable. It’s service life can up to 15 years or more. 2) Two kinds of start mode: Reduction Voltage Start and Variable Frequency Start. Customers can set start mode according to the type of their load. This function is very convenient for users and also reduce frequency converter’s usage, which reduced the cost of equipment investment, easy to connect wires and control. 3) Pure sine wave output with good transient response less than 50ms, waveform distortion is very little, higher conversion efficiency and stable output voltage. 4) Adopted low frequency transformer which ensure the input voltage and output voltage are completely electrical isolated to avoid interference. 5)Using the SVPWM space vector algorithm, high conversion efficiency, high instantaneous power and low no load loss conversion efficiency can reach more than 94%, no load loss is small. 6) Output AC Power is suitable for all types of electric appliances, electric tools, electric motors etc. higher capability of driving load. 7) Converter has the function of filtering the grid disturbance and interference at the same time, which is a good performance of stabilized voltage and frequency power, to provide a more stable and pure power supply environment for the backend devices. 8) Output perfect protection function, with output over voltage, overload, short circuit, over temperature, self diagnosis protection and other protection. 9) High conversion efficiency, high instantaneous power and low load loss. 10) The input voltage, output voltage, frequency and phase can be custom made. 11) DC input optional. Model LCS CNV 01 Isolation mode Low Frequency Transformer AC Input Input rated voltage (Vac) 3 phase 415V Input rated voltage range 380V/415V/440V/480Vac optional Input rated current(A) 240A AC Output Rated output power 100KW Output waveform Pure sine wave Phases Three phase, 4 wire Output rated voltage 220VAC ±3% Output voltage range 380/400/415/440/480Vac optional Output rated current 262A (phase current) Output Frequency 50Hz/60Hz±0.05Hz Power Factor(PF) 1 Overload Ability 150%, 10s Efficiency >94% Waveform distortion rate (THD) Dynamic Response (0 to 100% load) 5%,≤50ms Display LCD Running mode Working continuously Electrical insulation properties 2000Vac, 1 Minute Protection function Protection Input under voltage, over voltage, output over current, short circuit, overheating etc. Cooling method Fan cooled Short circuit protection No automatic recovery, need to restart the machine Working environment Ambient temperature 25~+55℃ Using environment humidity 0~90%,No condensation Noise ( 1 meter) ≤50dB Degree of protection IP20(indoor) Using altitude(m) ≤2000 Dimension (mm) 900x800x1200mm

ModelLCS-CNV-01
Isolation modeLow Frequency Transformer
AC InputInput rated voltage (Vac)3 phase 415V
Input rated voltage range380V/415V/440V/480Vac optional
Input rated current(A)240A
AC OutputRated output power100KW
Output waveformPure sine wave
PhasesThree phase, 4 wire
Output rated voltage220VAC ±3%
Output voltage range380/400/415/440/480Vac optional
Output rated current262A (phase current)
Output Frequency50Hz/60Hz±0.05Hz
Power Factor(PF)1
Overload Ability150%, 10s
Efficiency>94%
Waveform distortion rate (THD)
Dynamic Response (0 to 100% load)5%,≤50ms
DisplayLCD
Running modeWorking continuously
Electrical insulation properties2000Vac, 1 Minute
Protection functionProtectionInput under voltage, over voltage, output over-current, short circuit, overheating etc.
Cooling methodFan-cooled
Short-circuit protectionNo automatic recovery, need to restart the machine
Working environmentAmbient temperature-25~+55℃
Using environment humidity0~90%,No condensation
Noise ( 1 meter)≤50dB
Degree of protectionIP20(indoor)
Using altitude(m)≤2000
Dimension (mm)900x800x1200mm
LCS-CNV-02

Three Phase 220VAC to Three Phase 380VAC Converter 10KW

Digital Ultrasonic Generator MPPT Solar Charger Controller PWM Solar Charge Controller Wind Solar Hybrid Controller Grid Connected Inverter AC DC Batter Charger PV Combiner Box VLF High Voltage Generator 12 900V DC Contactor Photovoltaic Parts Soft Starter LCS CNV 02 3 phase 220VAC to 3 phase 380VAC Converter LCS CNV 02 Power phase converter, adopted AC DC AC circuit structure and SVPWM modulation control technology, which can convert ordinary single phase power to industrial three phase power. Two phase to three phase ,3 phase to 3 phase and so on.After through LCS CNV 02 power phase converter power conversion, the output is standard pure sine wave, the harmonic distortion rate (THD) is less than 2%, totally meet the national standards power quality, applicable to all types of load.

Technical Features for LCS CNV 02 3 phase 220VAC to 3 phase 380VAC Converter

1) Using the sixth generation efficient IPM intelligent module from Japanese Mitsubishi, high efficiency and stable performance. It with powerful protection function, the protection for short circuit, over load, over temperature is more safe and reliable. It’s service life can up to 15 years or more. 2) Two kinds of start mode: Reduction Voltage Start and Variable Frequency Start. Customers can set start mode according to the type of their load. This function is very convenient for users and also reduce frequency converter’s usage, which reduced the cost of equipment investment, easy to connect wires and control. 3) Pure sine wave output with good transient response less than 50ms, waveform distortion is very little, higher conversion efficiency and stable output voltage. 4) Adopted low frequency transformer which ensure the input voltage and output voltage are completely electrical isolated to avoid interference. 5)Using the SVPWM space vector algorithm, high conversion efficiency, high instantaneous power and low no load loss conversion efficiency can reach more than 94%, no load loss is small. 6) Output AC Power is suitable for all types of electric appliances, electric tools, electric motors etc. higher capability of driving load. 7) Converter has the function of filtering the grid disturbance and interference at the same time, which is a good performance of stabilized voltage and frequency power, to provide a more stable and pure power supply environment for the backend devices. 8) Output perfect protection function, with output over voltage, overload, short circuit, over temperature, self diagnosis protection and other protection. 9) High conversion efficiency, high instantaneous power and low load loss. 10) The input voltage, output voltage, frequency and phase can be custom made. 11) DC input optional.

Technical Data for LCS CNV 02 3 phase 220VAC to 3 phase 380VAC Converter

Model LCS CNV 02 Isolation Low Frequency Transformer AC Input Input rated voltage(VAC) 3 phase 220V/50HZ Input rated current(A) 45A AC Output Rated AC output power 10KW AC output waveform Pure sine wave Phases Three phase, 4 wires Output rated voltage 3phase 380VAC Output Frequency 50Hz±0.05Hz Output rated current(A) 15A (per phase) Power Factor(PF) 1 Overload Ability 150%, 10s Efficiency ≥92~95% Waveform distortion rate (THD) Crest Factor (CF) 3:1 Display LCD Electrical insulation properties 2500Vac, 1 Minute Ambient temperature 25~+55℃ Using environment humidity 0~90%,No condensation Protection Input under voltage, overvoltage, output over current, short circuit, overheating etc. Structure Cooling method Fan cooled Noise <40db Degree of protection IP20(indoor) Using altitude(m) ≤2500 Dimensions (mm) 550x550x860mm Weight (Kg) 135Kg CE Standard EN60950 1:2006+A11:2009, EN61000 6 4:2007+A1:2001, EN61000 6 2:2005, EN61000 3 12:2005, EN61000 3 11:2000

ModelLCS-CNV-02
IsolationLow Frequency Transformer
AC InputInput rated voltage(VAC)3 phase 220V/50HZ
Input rated current(A)45A
AC OutputRated AC output power10KW
AC output waveformPure sine wave
PhasesThree phase, 4 wires
Output rated voltage3phase 380VAC
Output Frequency50Hz±0.05Hz
Output rated current(A)15A (per phase)
Power Factor(PF)1
Overload Ability150%, 10s
Efficiency≥92~95%
Waveform distortion rate (THD)
Crest Factor (CF)3:1
DisplayLCD
Electrical insulation properties2500Vac, 1 Minute
Ambient temperature-25~+55℃
Using environment humidity0~90%,No condensation
ProtectionInput under voltage, overvoltage, output over-current, short circuit, overheating etc.
StructureCooling methodFan-cooled
Noise<40db
Degree of protectionIP20(indoor)
Using altitude(m)≤2500
Dimensions (mm)550x550x860mm
Weight (Kg)135Kg
CE StandardEN60950-1:2006+A11:2009, EN61000-6-4:2007+A1:2001, EN61000-6-2:2005, EN61000-3-12:2005, EN61000-3-11:2000
LCS-CNV-03

120 Degree Phase Voltage Converter 120KW

Digital Ultrasonic Generator MPPT Solar Charger Controller PWM Solar Charge Controller Wind Solar Hybrid Controller Grid Connected Inverter AC DC Batter Charger PV Combiner Box VLF High Voltage Generator 12 900V DC Contactor Photovoltaic Parts Soft Starter LCS CNV 03 120° phase voltage converter LCS CNV 03 Power phase converter, adopted AC DC AC circuit structure and SVPWM modulation control technology, which can convert ordinary single phase power to industrial three phase power. Two phase to three phase ,3 phase to 3 phase and so on.After through LCS CNV 03 power phase converter power conversion, the output is standard pure sine wave, the harmonic distortion rate (THD) is less than 2%, totally meet the national standards power quality, applicable to all types of load.

Technical Features

1) Using the sixth generation efficient IPM intelligent module from Japanese Mitsubishi, high efficiency and stable performance. It with powerful protection function, the protection for short circuit, over load, over temperature is more safe and reliable. It’s service life can up to 15 years or more. 2) Two kinds of start mode: Reduction Voltage Start and Variable Frequency Start. Customers can set start mode according to the type of their load. This function is very convenient for users and also reduce frequency converter’s usage, which reduced the cost of equipment investment, easy to connect wires and control. 3) Pure sine wave output with good transient response less than 50ms, waveform distortion is very little, higher conversion efficiency and stable output voltage. 4) Adopted low frequency transformer which ensure the input voltage and output voltage are completely electrical isolated to avoid interference. 5)Using the SVPWM space vector algorithm, high conversion efficiency, high instantaneous power and low no load loss conversion efficiency can reach more than 94%, no load loss is small. 6) Output AC Power is suitable for all types of electric appliances, electric tools, electric motors etc. higher capability of driving load. 7) Converter has the function of filtering the grid disturbance and interference at the same time, which is a good performance of stabilized voltage and frequency power, to provide a more stable and pure power supply environment for the backend devices. 8) Output perfect protection function, with output over voltage, overload, short circuit, over temperature, self diagnosis protection and other protection. 9) High conversion efficiency, high instantaneous power and low load loss. 10) The input voltage, output voltage, frequency and phase can be custom made. 11) DC input optional. Model LCS CNV 03 Isolation mode Low Frequency Transformer AC Input Input rated voltage (Vac) Single phase 460V 60Hz Input rated voltage range 220V/380V/415V/440V/480Vac optional Input rated current(A) 260A AC Output Rated output power 120KW Output waveform Pure sine wave Phases Split phase, 3 wire Output rated voltage 120/240VAC ±3% Output voltage range 220V/380V/400/415/440/480Vac optional Output rated current 500A (phase current) Output Frequency 50Hz/60Hz±0.05Hz Power Factor(PF) 1 Overload Ability 150%, 10s Efficiency >92% Waveform distortion rate (THD) Dynamic Response (0 to 100% load) 5%,≤50ms Display LCD Running mode Working continuously Electrical insulation properties 2000Vac, 1 Minute Protection function Protection Input under voltage, over voltage, output over current, short circuit, overheating etc. Cooling method Fan cooled Short circuit protection No automatic recovery, need to restart the machine Working environment Ambient temperature 25~+55℃ Using environment humidity 0~90%,No condensation Noise ( 1 meter) ≤50dB Degree of protection IP20(indoor)or IP45(Outdoor) Using altitude(m) ≤2000 Dimension (mm) 950x900x1580mm

ModelLCS-CNV-03
Isolation modeLow Frequency Transformer
AC InputInput rated voltage (Vac)Single phase 460V 60Hz
Input rated voltage range220V/380V/415V/440V/480Vac optional
Input rated current(A)260A
AC OutputRated output power120KW
Output waveformPure sine wave
PhasesSplit phase, 3 wire
Output rated voltage120/240VAC ±3%
Output voltage range220V/380V/400/415/440/480Vac optional
Output rated current500A (phase current)
Output Frequency50Hz/60Hz±0.05Hz
Power Factor(PF)1
Overload Ability150%, 10s
Efficiency>92%
Waveform distortion rate (THD)
Dynamic Response (0 to 100% load)5%,≤50ms
DisplayLCD
Running modeWorking continuously
Electrical insulation properties2000Vac, 1 Minute
Protection functionProtectionInput under voltage, over voltage, output over-current, short circuit, overheating etc.
Cooling methodFan-cooled
Short-circuit protectionNo automatic recovery, need to restart the machine
Working environmentAmbient temperature-25~+55℃
Using environment humidity0~90%,No condensation
Noise ( 1 meter)≤50dB
Degree of protectionIP20(indoor)or IP45(Outdoor)
Using altitude(m)≤2000
Dimension (mm)950x900x1580mm
LCS-CNV-04

440Vac 60Hz to 380Vac 50Hz Phase Voltage Converter 150KW

Digital Ultrasonic Generator MPPT Solar Charger Controller PWM Solar Charge Controller Wind Solar Hybrid Controller Grid Connected Inverter AC DC Batter Charger PV Combiner Box VLF High Voltage Generator 12 900V DC Contactor Photovoltaic Parts Soft Starter LCS CNV 04 440Vac 60Hz to 380Vac 50Hz Phase voltage converter LCS CNV 04 Power phase converter, adopted AC DC AC circuit structure and SVPWM modulation control technology, which can convert ordinary single phase power to industrial three phase power. Two phase to three phase ,3 phase to 3 phase and so on.After through LCS CNV 04 power phase converter power conversion, the output is standard pure sine wave, the harmonic distortion rate (THD) is less than 2%, totally meet the national standards power quality, applicable to all types of load.

Technical Features

1) Using the sixth generation efficient IPM intelligent module from Japanese Mitsubishi, high efficiency and stable performance. It with powerful protection function, the protection for short circuit, over load, over temperature is more safe and reliable. It’s service life can up to 15 years or more. 2) Two kinds of start mode: Reduction Voltage Start and Variable Frequency Start. Customers can set start mode according to the type of their load. This function is very convenient for users and also reduce frequency converter’s usage, which reduced the cost of equipment investment, easy to connect wires and control. 3) Pure sine wave output with good transient response less than 50ms, waveform distortion is very little, higher conversion efficiency and stable output voltage. 4) Adopted low frequency transformer which ensure the input voltage and output voltage are completely electrical isolated to avoid interference. 5)Using the SVPWM space vector algorithm, high conversion efficiency, high instantaneous power and low no load loss conversion efficiency can reach more than 94%, no load loss is small. 6) Output AC Power is suitable for all types of electric appliances, electric tools, electric motors etc. higher capability of driving load. 7) Converter has the function of filtering the grid disturbance and interference at the same time, which is a good performance of stabilized voltage and frequency power, to provide a more stable and pure power supply environment for the backend devices. 8) Output perfect protection function, with output over voltage, overload, short circuit, over temperature, self diagnosis protection and other protection. 9) High conversion efficiency, high instantaneous power and low load loss. 10) The input voltage, output voltage, frequency and phase can be custom made. 11) DC input optional. Model LCS CNV 04 Isolation mode Low Frequency Transformer AC Input Input rated voltage (Vac) 3 phase 440V 60Hz Input rated voltage range 380V/415V/440V/480Vac optional Input rated current(A) 340A AC Output Rated output power 150KW Output waveform Pure sine wave Phases Three phase, 4 wire Output rated voltage 380VAC ±3% Output voltage range 400/415/440/480Vac optional Output rated current 227A (phase current) Output Frequency 50Hz/60Hz±0.05Hz Power Factor(PF) 1 Overload Ability 150%, 10s Efficiency >92% Waveform distortion rate (THD) Dynamic Response (0 to 100% load) 5%,≤50ms Display LCD Running mode Working continuously Electrical insulation properties 2000Vac, 1 Minute Protection function Protection Input under voltage, over voltage, output over current, short circuit, overheating etc. Cooling method Fan cooled Short circuit protection No automatic recovery, need to restart the machine Working environment Ambient temperature 25~+55℃ Using environment humidity 0~90%,No condensation Noise ( 1 meter) ≤50dB Degree of protection IP20(indoor)or IP45(Outdoor) Using altitude(m) ≤2000 Dimension (mm) 1200x1200x1860mm

ModelLCS-CNV-04
Isolation modeLow Frequency Transformer
AC InputInput rated voltage (Vac)3 phase 440V 60Hz
Input rated voltage range380V/415V/440V/480Vac optional
Input rated current(A)340A
AC OutputRated output power150KW
Output waveformPure sine wave
PhasesThree phase, 4 wire
Output rated voltage380VAC ±3%
Output voltage range400/415/440/480Vac optional
Output rated current227A (phase current)
Output Frequency50Hz/60Hz±0.05Hz
Power Factor(PF)1
Overload Ability150%, 10s
Efficiency>92%
Waveform distortion rate (THD)
Dynamic Response (0 to 100% load)5%,≤50ms
DisplayLCD
Running modeWorking continuously
Electrical insulation properties2000Vac, 1 Minute
Protection functionProtectionInput under voltage, over voltage, output over-current, short circuit, overheating etc.
Cooling methodFan-cooled
Short-circuit protectionNo automatic recovery, need to restart the machine
Working environmentAmbient temperature-25~+55℃
Using environment humidity0~90%,No condensation
Noise ( 1 meter)≤50dB
Degree of protectionIP20(indoor)or IP45(Outdoor)
Using altitude(m)≤2000
Dimension (mm)1200x1200x1860mm
LCS-CNV-05

Digital Static Converter 200KW

MPPT Solar Charger Controller PWM Solar Charge Controller Wind Solar Hybrid Controller Grid Connected Inverter AC DC Batter Charger PV Combiner Box VLF High Voltage Generator 12 900V DC Contactor Photovoltaic Parts Soft Starter LCS CNV 05 Digital static converter LCS CNV 05 Power phase converter, adopted AC DC AC circuit structure and SVPWM modulation control technology, which can convert ordinary single phase power to industrial three phase power. Two phase to three phase ,3 phase to 3 phase and so on.After through LCS CNV 05 power phase converter power conversion, the output is standard pure sine wave, the harmonic distortion rate (THD) is less than 2%, totally meet the national standards power quality, applicable to all types of load.

Technical Features

1) Using the sixth generation efficient IPM intelligent module from Japanese Mitsubishi, high efficiency and stable performance. It with powerful protection function, the protection for short circuit, over load, over temperature is more safe and reliable. It’s service life can up to 15 years or more. 2) Two kinds of start mode: Reduction Voltage Start and Variable Frequency Start. Customers can set start mode according to the type of their load. This function is very convenient for users and also reduce frequency converter’s usage, which reduced the cost of equipment investment, easy to connect wires and control. 3) Pure sine wave output with good transient response less than 50ms, waveform distortion is very little, higher conversion efficiency and stable output voltage. 4) Adopted low frequency transformer which ensure the input voltage and output voltage are completely electrical isolated to avoid interference. 5)Using the SVPWM space vector algorithm, high conversion efficiency, high instantaneous power and low no load loss conversion efficiency can reach more than 94%, no load loss is small. 6) Output AC Power is suitable for all types of electric appliances, electric tools, electric motors etc. higher capability of driving load. 7) Converter has the function of filtering the grid disturbance and interference at the same time, which is a good performance of stabilized voltage and frequency power, to provide a more stable and pure power supply environment for the backend devices. 8) Output perfect protection function, with output over voltage, overload, short circuit, over temperature, self diagnosis protection and other protection. 9) High conversion efficiency, high instantaneous power and low load loss. 10) The input voltage, output voltage, frequency and phase can be custom made. 11) DC input optional. Model LCS CNV 05 Isolation mode Low Frequency Transformer AC Input Input rated voltage (Vac) 3 phase 480V Input rated voltage range 380V/415V/440V/480Vac optional Input rated current(A) 416A AC Output Rated output power 200KW Output waveform Pure sine wave Phases Three phase, 4 wire Output rated voltage 380VAC ±3% Output voltage range 400/415/440/480Vac optional Output rated current 303A (phase current) Output Frequency 50Hz/60Hz±0.05Hz Power Factor(PF) 1 Overload Ability 150%, 10s Efficiency >92% Waveform distortion rate (THD) Dynamic Response (0 to 100% load) 5%,≤50ms Display LCD Running mode Working continuously Electrical insulation properties 2000Vac, 1 Minute Protection function Protection Input under voltage, over voltage, output over current, short circuit, overheating etc. Cooling method Fan cooled Short circuit protection No automatic recovery, need to restart the machine Working environment Ambient temperature 25~+55℃ Using environment humidity 0~90%,No condensation Noise ( 1 meter) ≤50dB Degree of protection IP20(indoor) Using altitude(m) ≤2000 Dimension (mm) 1200x1200x1860mm

ModelLCS-CNV-05
Isolation modeLow Frequency Transformer
AC InputInput rated voltage (Vac)3 phase 480V
Input rated voltage range380V/415V/440V/480Vac optional
Input rated current(A)416A
AC OutputRated output power200KW
Output waveformPure sine wave
PhasesThree phase, 4 wire
Output rated voltage380VAC ±3%
Output voltage range400/415/440/480Vac optional
Output rated current303A (phase current)
Output Frequency50Hz/60Hz±0.05Hz
Power Factor(PF)1
Overload Ability150%, 10s
Efficiency>92%
Waveform distortion rate (THD)
Dynamic Response (0 to 100% load)5%,≤50ms
DisplayLCD
Running modeWorking continuously
Electrical insulation properties2000Vac, 1 Minute
Protection functionProtectionInput under voltage, over voltage, output over-current, short circuit, overheating etc.
Cooling methodFan-cooled
Short-circuit protectionNo automatic recovery, need to restart the machine
Working environmentAmbient temperature-25~+55℃
Using environment humidity0~90%,No condensation
Noise ( 1 meter)≤50dB
Degree of protectionIP20(indoor)
Using altitude(m)≤2000
Dimension (mm)1200x1200x1860mm
LCS-CNV-06

120 and 240V Split Phase to 127 and 220V Three Phase Phase Voltage Converter 20KW

Digital Ultrasonic Generator MPPT Solar Charger Controller PWM Solar Charge Controller Wind Solar Hybrid Controller Grid Connected Inverter AC DC Batter Charger PV Combiner Box VLF High Voltage Generator 12 900V DC Contactor Photovoltaic Parts Soft Starter LCS CNV 06 120/240V split phase to 127/220V 3 phase Phase voltage converter LCS CNV 06 Power phase converter, adopted AC DC AC circuit structure and SVPWM modulation control technology, which can convert ordinary single phase power to industrial three phase power. Two phase to three phase ,3 phase to 3 phase and so on.After through LCS CNV 06 power phase converter power conversion, the output is standard pure sine wave, the harmonic distortion rate (THD) is less than 2%, totally meet the national standards power quality, applicable to all types of load.

Technical Features

1) Using the sixth generation efficient IPM intelligent module from Japanese Mitsubishi, high efficiency and stable performance. It with powerful protection function, the protection for short circuit, over load, over temperature is more safe and reliable. It’s service life can up to 15 years or more. 2) Two kinds of start mode: Reduction Voltage Start and Variable Frequency Start. Customers can set start mode according to the type of their load. This function is very convenient for users and also reduce frequency converter’s usage, which reduced the cost of equipment investment, easy to connect wires and control. 3) Pure sine wave output with good transient response less than 50ms, waveform distortion is very little, higher conversion efficiency and stable output voltage. 4) Adopted low frequency transformer which ensure the input voltage and output voltage are completely electrical isolated to avoid interference. 5)Using the SVPWM space vector algorithm, high conversion efficiency, high instantaneous power and low no load loss conversion efficiency can reach more than 94%, no load loss is small. 6) Output AC Power is suitable for all types of electric appliances, electric tools, electric motors etc. higher capability of driving load. 7) Converter has the function of filtering the grid disturbance and interference at the same time, which is a good performance of stabilized voltage and frequency power, to provide a more stable and pure power supply environment for the backend devices. 8) Output perfect protection function, with output over voltage, overload, short circuit, over temperature, self diagnosis protection and other protection. 9) High conversion efficiency, high instantaneous power and low load loss. 10) The input voltage, output voltage, frequency and phase can be custom made. 11) DC input optional.

Technical Data

for LCS CNV 06 120/240V split phase to 127/220V 3 phase Phase voltage converter Model LCS CNV 06 Isolation Low Frequency Transformer AC Input Input rated voltage(VAC) Split phase 120/240V Input rated current(A) 83A AC Output Rated AC output power 20KW AC output waveform Pure sine wave Phases Three phase, 4 wires Output rated voltage 3 phase 220VAC Output Frequency 50Hz±0.05Hz Output rated current(A) 53A (per phase) Power Factor(PF) 1 Overload Ability 150%, 10s Efficiency ≥92~95% Waveform distortion rate (THD) Crest Factor (CF) 3:1 Display LCD Electrical insulation properties 2500Vac, 1 Minute Ambient temperature 25~+55℃ Using environment humidity 0~90%,No condensation Protection Input under voltage, overvoltage, output over current, short circuit, overheating etc. Structure Cooling method Fan cooled Noise <40db Degree of protection IP20(indoor)or IP45(outdoor) Using altitude(m) ≤2500 Dimensions (mm) 550x550x860mm Weight (Kg) 180Kg CE Standard EN60950 1:2006+A11:2009, EN61000 6 4:2007+A1:2001, EN61000 6 2:2005, EN61000 3 12:2005, EN61000 3 11:2000

ModelLCS-CNV-06
IsolationLow Frequency Transformer
AC InputInput rated voltage(VAC)Split phase 120/240V
Input rated current(A)83A
AC OutputRated AC output power20KW
AC output waveformPure sine wave
PhasesThree phase, 4 wires
Output rated voltage3 phase 220VAC
Output Frequency50Hz±0.05Hz
Output rated current(A)53A (per phase)
Power Factor(PF)1
Overload Ability150%, 10s
Efficiency≥92~95%
Waveform distortion rate (THD)
Crest Factor (CF)3:1
DisplayLCD
Electrical insulation properties2500Vac, 1 Minute
Ambient temperature-25~+55℃
Using environment humidity0~90%,No condensation
ProtectionInput under voltage, overvoltage, output over-current, short circuit, overheating etc.
StructureCooling methodFan-cooled
Noise<40db
Degree of protectionIP20(indoor)or IP45(outdoor)
Using altitude(m)≤2500
Dimensions (mm)550x550x860mm
Weight (Kg)180Kg
CE StandardEN60950-1:2006+A11:2009, EN61000-6-4:2007+A1:2001, EN61000-6-2:2005, EN61000-3-12:2005, EN61000-3-11:2000
LCS-CNV-07

Three Phase 400V 50Hz to Three Phase 208V 60Hz Converter 25KW

Digital Ultrasonic Generator MPPT Solar Charger Controller PWM Solar Charge Controller Wind Solar Hybrid Controller Grid Connected Inverter AC DC Batter Charger PV Combiner Box VLF High Voltage Generator 12 900V DC Contactor Photovoltaic Parts Soft Starter LCS CNV 07 3 phase 400V 50HZ to 3 phase 208V 60HZ converter LCS CNV 07 Power phase converter, adopted AC DC AC circuit structure and SVPWM modulation control technology, which can convert ordinary single phase power to industrial three phase power. Two phase to three phase ,3 phase to 3 phase and so on.After through LCS CNV 07 power phase converter power conversion, the output is standard pure sine wave, the harmonic distortion rate (THD) is less than 2%, totally meet the national standards power quality, applicable to all types of load.

Technical Features

1) Using the sixth generation efficient IPM intelligent module from Japanese Mitsubishi, high efficiency and stable performance. It with powerful protection function, the protection for short circuit, over load, over temperature is more safe and reliable. It’s service life can up to 15 years or more. 2) Two kinds of start mode: Reduction Voltage Start and Variable Frequency Start. Customers can set start mode according to the type of their load. This function is very convenient for users and also reduce frequency converter’s usage, which reduced the cost of equipment investment, easy to connect wires and control. 3) Pure sine wave output with good transient response less than 50ms, waveform distortion is very little, higher conversion efficiency and stable output voltage. 4) Adopted low frequency transformer which ensure the input voltage and output voltage are completely electrical isolated to avoid interference. 5)Using the SVPWM space vector algorithm, high conversion efficiency, high instantaneous power and low no load loss conversion efficiency can reach more than 94%, no load loss is small. 6) Output AC Power is suitable for all types of electric appliances, electric tools, electric motors etc. higher capability of driving load. 7) Converter has the function of filtering the grid disturbance and interference at the same time, which is a good performance of stabilized voltage and frequency power, to provide a more stable and pure power supply environment for the backend devices. 8) Output perfect protection function, with output over voltage, overload, short circuit, over temperature, self diagnosis protection and other protection. 9) High conversion efficiency, high instantaneous power and low load loss. 10) The input voltage, output voltage, frequency and phase can be custom made. 11) DC input optional. Model LCS CNV 07 Isolation mode Low Frequency Transformer AC Input Input rated voltage (Vac) 3 phase 400V Input rated voltage range 110/120/220/230/240V/380V/415V/440V/480Vac optional Input rated current(A)

62.5A AC Output Rated output power 25KW Output waveform Pure sine wave Phases Three phase, 4 wire Output rated voltage 208VAC ±3% Output voltage range 220/380/400/415/440/480Vac optional Output rated current 69A (phase current) Output Frequency 50Hz/60Hz±0.05Hz Power Factor(PF) 1 Overload Ability 150%, 10s Efficiency >92% Waveform distortion rate (THD) Dynamic Response (0 to 100% load) 5%,≤50ms Display LCD Running mode Working continuously Electrical insulation properties 2000Vac, 1 Minute Protection function Protection Input under voltage, over voltage, output over current, short circuit, overheating etc. Cooling method Fan cooled Short circuit protection No automatic recovery, need to restart the machine Working environment Ambient temperature 25~+55℃ Using environment humidity 0~90%,No condensation Noise ( 1 meter) ≤50dB Degree of protection IP20(indoor) Using altitude(m) ≤2000 Dimension (mm) 700x550x1000mm

ModelLCS-CNV-07
Isolation modeLow Frequency Transformer
AC InputInput rated voltage (Vac)3 phase 400V
Input rated voltage range110/120/220/230/240V/380V/415V/440V/480Vac optional
Input rated current(A)62.5A
AC OutputRated output power25KW
Output waveformPure sine wave
PhasesThree phase, 4 wire
Output rated voltage208VAC ±3%
Output voltage range220/380/400/415/440/480Vac optional
Output rated current69A (phase current)
Output Frequency50Hz/60Hz±0.05Hz
Power Factor(PF)1
Overload Ability150%, 10s
Efficiency>92%
Waveform distortion rate (THD)
Dynamic Response (0 to 100% load)5%,≤50ms
DisplayLCD
Running modeWorking continuously
Electrical insulation properties2000Vac, 1 Minute
Protection functionProtectionInput under voltage, over voltage, output over-current, short circuit, overheating etc.
Cooling methodFan-cooled
Short-circuit protectionNo automatic recovery, need to restart the machine
Working environmentAmbient temperature-25~+55℃
Using environment humidity0~90%,No condensation
Noise ( 1 meter)≤50dB
Degree of protectionIP20(indoor)
Using altitude(m)≤2000
Dimension (mm)700x550x1000mm
LCS-CNV-08

240Vac to 380Vac Static Phase Converter 30KW

Digital Ultrasonic Generator MPPT Solar Charger Controller PWM Solar Charge Controller Wind Solar Hybrid Controller Grid Connected Inverter AC DC Batter Charger PV Combiner Box VLF High Voltage Generator 12 900V DC Contactor Photovoltaic Parts Soft Starter LCS CNV 08 240Vac to 380Vac Static Phase Converter LCS CNV 08 Power phase converter, adopted AC DC AC circuit structure and SVPWM modulation control technology, which can convert ordinary single phase power to industrial three phase power. Two phase to three phase ,3 phase to 3 phase and so on.After through LCS CNV 08 power phase converter power conversion, the output is standard pure sine wave, the harmonic distortion rate (THD) is less than 2%, totally meet the national standards power quality, applicable to all types of load.

Technical Features

1) Using the sixth generation efficient IPM intelligent module from Japanese Mitsubishi, high efficiency and stable performance. It with powerful protection function, the protection for short circuit, over load, over temperature is more safe and reliable. It’s service life can up to 15 years or more. 2) Two kinds of start mode: Reduction Voltage Start and Variable Frequency Start. Customers can set start mode according to the type of their load. This function is very convenient for users and also reduce frequency converter’s usage, which reduced the cost of equipment investment, easy to connect wires and control. 3) Pure sine wave output with good transient response less than 50ms, waveform distortion is very little, higher conversion efficiency and stable output voltage. 4) Adopted low frequency transformer which ensure the input voltage and output voltage are completely electrical isolated to avoid interference. 5)Using the SVPWM space vector algorithm, high conversion efficiency, high instantaneous power and low no load loss conversion efficiency can reach more than 94%, no load loss is small. 6) Output AC Power is suitable for all types of electric appliances, electric tools, electric motors etc. higher capability of driving load. 7) Converter has the function of filtering the grid disturbance and interference at the same time, which is a good performance of stabilized voltage and frequency power, to provide a more stable and pure power supply environment for the backend devices. 8) Output perfect protection function, with output over voltage, overload, short circuit, over temperature, self diagnosis protection and other protection. 9) High conversion efficiency, high instantaneous power and low load loss. 10) The input voltage, output voltage, frequency and phase can be custom made. 11) DC input optional. Model LCS CNV 08 Isolation mode Low Frequency Transformer AC Input Input rated voltage (Vac) single phase 240V Input rated voltage range 110/120/220/230/240V/380V/415V/440V/480Vac optional Input rated current(A) 125A AC Output Rated output power 30KW Output waveform Pure sine wave Phases Three phase, 4 wire Output rated voltage 380VAC ±3% Output voltage range 220/380/400/415/440/480Vac optional Output rated current 45A (phase current) Output Frequency 50Hz/60Hz±0.05Hz Power Factor(PF) 1 Overload Ability 150%, 10s Efficiency >92% Waveform distortion rate (THD) Dynamic Response (0 to 100% load) 5%,≤50ms Display LCD Running mode Working continuously Electrical insulation properties 2000Vac, 1 Minute Protection function Protection Input under voltage, over voltage, output over current, short circuit, overheating etc. Cooling method Fan cooled Short circuit protection No automatic recovery, need to restart the machine Working environment Ambient temperature 25~+55℃ Using environment humidity 0~90%,No condensation Noise ( 1 meter) ≤50dB Degree of protection IP20(indoor)or IP45(Outdoor) Using altitude(m) ≤2000 Dimension (mm) 600x700x1080mm

ModelLCS-CNV-08
Isolation modeLow Frequency Transformer
AC InputInput rated voltage (Vac)single phase 240V
Input rated voltage range110/120/220/230/240V/380V/415V/440V/480Vac optional
Input rated current(A)125A
AC OutputRated output power30KW
Output waveformPure sine wave
PhasesThree phase, 4 wire
Output rated voltage380VAC ±3%
Output voltage range220/380/400/415/440/480Vac optional
Output rated current45A (phase current)
Output Frequency50Hz/60Hz±0.05Hz
Power Factor(PF)1
Overload Ability150%, 10s
Efficiency>92%
Waveform distortion rate (THD)
Dynamic Response (0 to 100% load)5%,≤50ms
DisplayLCD
Running modeWorking continuously
Electrical insulation properties2000Vac, 1 Minute
Protection functionProtectionInput under voltage, over voltage, output over-current, short circuit, overheating etc.
Cooling methodFan-cooled
Short-circuit protectionNo automatic recovery, need to restart the machine
Working environmentAmbient temperature-25~+55℃
Using environment humidity0~90%,No condensation
Noise ( 1 meter)≤50dB
Degree of protectionIP20(indoor)or IP45(Outdoor)
Using altitude(m)≤2000
Dimension (mm)600x700x1080mm
LCS-CNV-09

Single Phase 220VAC to Three Phase 380VAC Converter 3KW

Digital Ultrasonic Generator MPPT Solar Charger Controller PWM Solar Charge Controller Wind Solar Hybrid Controller Grid Connected Inverter AC DC Batter Charger PV Combiner Box VLF High Voltage Generator 12 900V DC Contactor Photovoltaic Parts Soft Starter LCS CNV 09 Single phase 220VAC to Three phase 380VAC Converter LCS CNV 09 Power phase converter, adopted AC DC AC circuit structure and SVPWM modulation control technology, which can convert ordinary single phase power to industrial three phase power. Two phase to three phase ,3 phase to 3 phase and so on.After through LCS CNV 09 power phase converter power conversion, the output is standard pure sine wave, the harmonic distortion rate (THD) is less than 2%, totally meet the national standards power quality, applicable to all types of load.

Technical Features for LCS CNV 09 Single phase 220VAC to Three phase 380VAC Converter

1) Using the sixth generation efficient IPM intelligent module from Japanese Mitsubishi, high efficiency and stable performance. It with powerful protection function, the protection for short circuit, over load, over temperature is more safe and reliable. It’s service life can up to 15 years or more. 2) Two kinds of start mode: Reduction Voltage Start and Variable Frequency Start. Customers can set start mode according to the type of their load. This function is very convenient for users and also reduce frequency converter’s usage, which reduced the cost of equipment investment, easy to connect wires and control. 3) Pure sine wave output with good transient response less than 50ms, waveform distortion is very little, higher conversion efficiency and stable output voltage. 4) Adopted low frequency transformer which ensure the input voltage and output voltage are completely electrical isolated to avoid interference. 5)Using the SVPWM space vector algorithm, high conversion efficiency, high instantaneous power and low no load loss conversion efficiency can reach more than 94%, no load loss is small. 6) Output AC Power is suitable for all types of electric appliances, electric tools, electric motors etc. higher capability of driving load. 7) Converter has the function of filtering the grid disturbance and interference at the same time, which is a good performance of stabilized voltage and frequency power, to provide a more stable and pure power supply environment for the backend devices. 8) Output perfect protection function, with output over voltage, overload, short circuit, over temperature, self diagnosis protection and other protection. 9) High conversion efficiency, high instantaneous power and low load loss. 10) The input voltage, output voltage, frequency and phase can be custom made. 11) DC input optional.

Technical Data for LCS CNV 09 Single phase 220VAC to Three phase 380VAC Converter

Model LCS CNV 09 Isolation Low Frequency Transformer AC Input Input rated voltage(VAC) Single phase 220V Input rated current(A)

13.6A AC Output Rated AC output power 3KW AC output waveform Pure sine wave Phases Three phase, 4 wires Output rated voltage 400VAC ±3% Output Frequency 50Hz±0.05Hz Output rated current(A)

7.9A Power Factor(PF)

0.9 Overload Ability 150%, 10s Efficiency ≥92~95% Waveform distortion rate (THD) Crest Factor (CF) 3:1 Display LCD Electrical insulation properties 2500Vac, 1 Minute Ambient temperature 15~+55℃ Using environment humidity 0~90%,No condensation Protection Input under voltage, overvoltage, output over current, short circuit, overheating etc. Structure Cooling method Fan cooled Noise Degree of protection IP20(indoor) Using altitude(m) ≤2500 Dimensions (mm) 550x450x760mm Weight (Kg) 72Kg CE Standard EN60950 1:2006+A11:2009, EN61000 6 4:2007+A1:2001, EN61000 6 2:2005, EN61000 3 12:2005, EN61000 3 11:2000

ModelLCS-CNV-09
IsolationLow Frequency Transformer
AC InputInput rated voltage(VAC)Single phase 220V
Input rated current(A)13.6A
AC OutputRated AC output power3KW
AC output waveformPure sine wave
PhasesThree phase, 4 wires
Output rated voltage400VAC ±3%
Output Frequency50Hz±0.05Hz
Output rated current(A)7.9A
Power Factor(PF)0.9
Overload Ability150%, 10s
Efficiency≥92~95%
Waveform distortion rate (THD)
Crest Factor (CF)3:1
DisplayLCD
Electrical insulation properties2500Vac, 1 Minute
Ambient temperature-15~+55℃
Using environment humidity0~90%,No condensation
ProtectionInput under voltage, overvoltage, output over-current, short circuit, overheating etc.
StructureCooling methodFan-cooled
Noise
Degree of protectionIP20(indoor)
Using altitude(m)≤2500
Dimensions (mm)550x450x760mm
Weight (Kg)72Kg
CE StandardEN60950-1:2006+A11:2009, EN61000-6-4:2007+A1:2001, EN61000-6-2:2005, EN61000-3-12:2005, EN61000-3-11:2000
LCS-CNV-10

Single Phase 60Hz to Three Phase 50Hz Frequency Converter 10KW

This series power converter uses an AC DC AC circuit structure with SVPWM vector algorithm modulation control technology to convert ordinary single phase power to industrial three phase power, two phase to three phase, three phase voltage conversion or frequency conversion.

The converted power is a standard pure sine wave with a 120 degree phase angle and harmonic distortion below 2 percent, suitable for all load types including welders, argon arc welders, electric hoists, rolling doors, packaging machines, motors, lathes, elevators, compressors and similar loads.

Performance features:

Ordinary mains input, two phase input or three phase input, giving pure sine wave output suitable for every AC load type where three phase power is unavailable or equipment voltage does not match.

Dual mode start selection through the LCD screen, with reduced voltage start and variable frequency start.

The power supply filters mains disturbance and interference and works as a stable frequency and stable voltage supply for downstream equipment.

Sixth generation IPM module with short circuit, overload and over temperature protection and a service life of more than 15 years.

Pure sine wave output with fast transient response, low waveform distortion, high efficiency and stable output voltage.

Low frequency isolation transformer, high reliability, high stability, high vibration resistance, no noise and no pollution.

SVPWM space vector algorithm with conversion efficiency above 94 percent and low no load loss.

Optional DC input, and input voltage, output voltage and frequency can be customized to customer requirements.

ModelLCS-CNV-10
AC inputInput rated voltage(VAC)Single phase220V
Input rated current(A)45A
AC outputRated output power (KW)10KW
Output waveformPure sine wave
Output rated voltageThree phase4 wire,380V±3%
Output frequency50Hz/60Hz±0.05Hz
Output rated current(A)15.1A (phase current)
Power factor(PF)0.95
StructureOverload capacity150%, 10s
Inverter efficiency>92%
Crest factor (CF)3:1
DisplayLCD
Insulation strength(Input and Output)2500Vac, 1 minute
Operating temperature and humidity range-25~+55℃
Relative humidity0~90%,no condensation
ProtectionInput undervoltage, output overload, short circuit and overheat protection
Cooling methodFan
Noise<40db
Protection ratingIP20(indoor)
Altitude(m)≤3000
Dimensions (H x W x D)550x550x860mm
Weight (kg)150Kg
CE StandardEN60950-1:2006+A11:2009, EN61000-6-4:2007+A1:2001, EN61000-6-2:2005, EN61000-3-12:2005, EN61000-3-11:2000
Single Phase 60Hz to Three Phase 50Hz Frequency Converter 10KW
LCS-CNV-11

Three Phase 380V to Three Phase 240V Voltage Converter 20KW

This series power converter uses an AC DC AC circuit structure with SVPWM vector algorithm modulation control technology to convert ordinary single phase power to industrial three phase power, two phase to three phase, three phase voltage conversion or frequency conversion.

The converted power is a standard pure sine wave with a 120 degree phase angle and harmonic distortion below 2 percent, suitable for all load types including welders, argon arc welders, electric hoists, rolling doors, packaging machines, motors, lathes, elevators, compressors and similar loads.

Performance features:

Ordinary mains input, two phase input or three phase input, giving pure sine wave output suitable for every AC load type where three phase power is unavailable or equipment voltage does not match.

Dual mode start selection through the LCD screen, with reduced voltage start and variable frequency start.

The power supply filters mains disturbance and interference and works as a stable frequency and stable voltage supply for downstream equipment.

Sixth generation IPM module with short circuit, overload and over temperature protection and a service life of more than 15 years.

Pure sine wave output with fast transient response, low waveform distortion, high efficiency and stable output voltage.

Low frequency isolation transformer, high reliability, high stability, high vibration resistance, no noise and no pollution.

SVPWM space vector algorithm with conversion efficiency above 94 percent and low no load loss.

Optional DC input, and input voltage, output voltage and frequency can be customized to customer requirements.

ModelLCS-CNV-11
AC inputInput rated voltage(VAC)Three phase380V
Input rated current(A)53A
AC outputRated output power (KW)20KW
Output waveformPure sine wave
Output rated voltageThree phase4 wire,240V±3%
Output frequency50Hz/60Hz±0.05Hz
Output rated current(A)48A(phase current)
Power factor(PF)0.95
StructureOverload capacity150%, 10s
Inverter efficiency>92%
Crest factor (CF)3:1
DisplayLCD
Insulation strength(Input and Output)2500Vac, 1 minute
Operating temperature and humidity range-25~+55℃
Relative humidity0~90%,no condensation
ProtectionInput undervoltage, output overload, short circuit and overheat protection
Cooling methodFan
Noise<40db
Protection ratingIP20(indoor)
Altitude(m)≤3000
Dimensions (H x W x D)550x550x860mm
Weight (kg)250Kg
CE StandardEN60950-1:2006+A11:2009, EN61000-6-4:2007+A1:2001, EN61000-6-2:2005, EN61000-3-12:2005, EN61000-3-11:2000
LCS-CNV-12

380V to 220V Voltage Phase Converter 6KW

This series power converter uses an AC DC AC circuit structure with SVPWM vector algorithm modulation control technology to convert ordinary single phase power to industrial three phase power, two phase to three phase, three phase voltage conversion or frequency conversion.

The converted power is a standard pure sine wave with a 120 degree phase angle and harmonic distortion below 2 percent, suitable for all load types including welders, argon arc welders, electric hoists, rolling doors, packaging machines, motors, lathes, elevators, compressors and similar loads.

Performance features:

Ordinary mains input, two phase input or three phase input, giving pure sine wave output suitable for every AC load type where three phase power is unavailable or equipment voltage does not match.

Dual mode start selection through the LCD screen, with reduced voltage start and variable frequency start.

The power supply filters mains disturbance and interference and works as a stable frequency and stable voltage supply for downstream equipment.

Sixth generation IPM module with short circuit, overload and over temperature protection and a service life of more than 15 years.

Pure sine wave output with fast transient response, low waveform distortion, high efficiency and stable output voltage.

Low frequency isolation transformer, high reliability, high stability, high vibration resistance, no noise and no pollution.

SVPWM space vector algorithm with conversion efficiency above 94 percent and low no load loss.

Optional DC input, and input voltage, output voltage and frequency can be customized to customer requirements.

ModelLCS-CNV-12
AC inputInput rated voltage(VAC)Three phase380V
Input rated current(A)16A
AC outputRated output power (KW)6KW
Output waveformPure sine wave
Output rated voltageThree phase4 wire,220V±3%
Output frequency60Hz±0.05Hz
Output rated current(A)16A (phase current)
Power factor(PF)1
StructureOverload capacity150%, 10s
Inverter efficiency>92%
Crest factor (CF)3:1
DisplayLCD
Insulation strength(Input and Output)2500Vac, 1 minute
Operating temperature and humidity range-25~+55℃
Relative humidity0~90%,no condensation
ProtectionInput undervoltage, output overload, short circuit and overheat protection
Cooling methodFan
Noise<40db
Protection ratingIP20(indoor)
Altitude(m)≤3000
Dimensions (H x W x D)550x550x860mm
Weight (kg)88Kg
CE StandardEN60950-1:2006+A11:2009, EN61000-6-4:2007+A1:2001, EN61000-6-2:2005, EN61000-3-12:2005, EN61000-3-11:2000

Soft Starters

LCS-SST-01

Intelligent Motor Soft Starter 11kW to 450kW

This soft starter series uses dual CPU control technology at its core, controlling a thyristor module to give squirrel cage three phase AC asynchronous motors soft start and soft stop functions, together with optional protection functions including overload, input phase loss, output phase loss, load short circuit, start current limit timeout, over voltage and under voltage. After starting the motor the product works online directly with no AC contactor. Ratings cover 11kW to 450kW for motor drive equipment in metallurgy, fire protection, mining, water supply, municipal, food, cement and petrochemical fields, as an ideal replacement for traditional star delta starting and autotransformer reduced voltage starting. Standards: GB 14048.6 and IEC 60947 4 2.

Features include a humanized artistic design with a beautiful appearance, firm and reliable build, complete functions, simple operation, reasonable structure and space saving, a complete LED and LCD dual display interface, SMT production process, excellent electromagnetic compatibility, full process system tracking testing, and deep high temperature aging and vibration testing.

Reliable functions and protection measures include simple external connection, programmable input and output terminals, RS232 and RS485 communication, standard analog output of 0 to 20mA, accurate current detection, accurate under voltage and over voltage protection, accurate system over temperature protection, external alarm input protection, output load short circuit protection, input phase loss protection and start timeout protection.

Digital Ultrasonic Generator MPPT Solar Charger Controller PWM Solar Charge Controller Wind Solar Hybrid Controller Grid Connected Inverter AC DC Batter Charger PV Combiner Box VLF High Voltage Generator 12 900V DC Contactor Photovoltaic Parts Soft Starter

Technical specifcation

Operation Control mode Keyboard/extermal terminal/RS485 communication Starting mode Current limiting/voltage/keavy load Start and stop time Can be set digitally Start delay Can be set digitally Emergency stop Stop the output of the soft starter Limiting current The starting current should be lower than the limiting current if the soft starter is operating under current limiting or heavy load mode Starting voltage The starting voltage can be set digitally if the soft starter is operating under voltage mode Load control Possibility to check accidents including belt tripping Autonmatic restart Autonmatic restart after breakdown Fault output Contact output AC 250V 1A ;DC30V 1A Multi function relay output Start delay, Start,Operation,Stop,Full stop restart Analogue output 0~20mA / 4~20mA available Portection function Portection of soft starter Protecting from overload,overcurrent,overheat,unbalanced three phase, missing phase,under loading,extemal fault,etc Warning of soft starter Emergency stop,under loading,restart,etc Display Keyboard Operation information Operation,stop and fault warnings during standby,start delay and starting Protection Protect the parameters from being modified Application conditions Application category AC 53b Rated insulation voltage 660V Rated impulse withstand voltage 4KV Protection degree IP20 Environment conditions Ambient temperature 10℃~40℃ Storage temperature 20℃~65℃ Storage temperature Maximum90%RH(No condensation) Ambient humidity Below 1000m;below 5.9m/s(=0.6g) Altitude/vibration Without corrosive gas,flammable gas,oil mist,dust or others Cooling Natural air cooling Model Rated Power (KW) Rated Current (A) Packing Size Mounting Size Weight Kg H1 W1 D H2 W2 D LCS SST 01 11 23 245 160 170 220 140 M6 <3.5 LCS SST 01 15 30 245 160 170 220 140 M6 <3.5 LCS SST 01

18.5 37 245 160 170 220 140 M6 <3.5 LCS SST 01 22 45 245 160 170 220 140 M6 <3.5 LCS SST 01 30 60 245 160 170 220 140 M6 <3.5 LCS SST 01 37 75 245 160 170 220 140 M6 <3.5 LCS SST 01 45 90 245 160 170 220 140 M6 <3.5 LCS SST 01 55 110 245 160 170 220 140 M6 <3.5 LCS SST 01 75 145 545 280 208 415 245 M8 <25 LCS SST 01 90 175 545 280 208 415 245 M8 <25 LCS SST 01 110 210 545 280 208 415 245 M8 <25 LCS SST 01 132 250 545 280 208 415 245 M8 <25 LCS SST 01 160 300 545 280 208 415 245 M8 <25 LCS SST 01 200 370 545 280 208 415 245 M8 <25 LCS SST 01 250 470 575 310 208 445 279 M8 <35 LCS SST 01 315 570 575 310 208 445 279 M8 <35 LCS SST 01 400 720 600 350 220 475 320 M8 <40 LCS SST 01 450 840 600 350 220 475 320 M8 <40

OperationControl modeKeyboard/extermal terminal/RS485 communication
Starting modeCurrent limiting/voltage/keavy load
Start and stop timeCan be set digitally
Start delayCan be set digitally
Emergency stopStop the output of the soft starter
Limiting currentThe starting current should be lower than the limiting current if the soft starter is operating under current limiting or heavy load mode
Starting voltageThe starting voltage can be set digitally if the soft starter is operating under voltage mode
Load controlPossibility to check accidents including belt tripping
Autonmatic restartAutonmatic restart after breakdown
Fault outputContact output AC 250V 1A ;DC30V 1A
Multi-function relay outputStart delay, Start,Operation,Stop,Full stop restart
Analogue output0~20mA / 4~20mA  available
Portection functionPortection of soft starterProtecting from overload,overcurrent,overheat,unbalanced three phase, missing phase,under loading,extemal fault,etc
Warning of soft starterEmergency stop,under loading,restart,etc
DisplayKeyboardOperation informationOperation,stop and fault warnings during standby,start delay and starting
ProtectionProtect the parameters from being modified
Application conditionsApplication categoryAC-53b
Rated insulation voltage660VRated impulse withstand voltage4KV
Protection degreeIP20
Environment conditionsAmbient temperature-10℃~40℃
Storage temperature-20℃~65℃
Storage temperatureMaximum90%RH(No condensation)
Ambient humidityBelow 1000m;below 5.9m/s(=0.6g)
Altitude/vibrationWithout corrosive gas,flammable gas,oil mist,dust or others
CoolingNatural air cooling
ModelRated Power (KW)Rated Current (A)Packing SizeMounting SizeWeight Kg
H1W1DH2W2D
LCS-SST-011123245160170220140M6<3.5
LCS-SST-011530245160170220140M6<3.5
LCS-SST-0118.537245160170220140M6<3.5
LCS-SST-012245245160170220140M6<3.5
LCS-SST-013060245160170220140M6<3.5
LCS-SST-013775245160170220140M6<3.5
LCS-SST-014590245160170220140M6<3.5
LCS-SST-0155110245160170220140M6<3.5
LCS-SST-0175145545280208415245M8<25
LCS-SST-0190175545280208415245M8<25
LCS-SST-01110210545280208415245M8<25
LCS-SST-01132250545280208415245M8<25
LCS-SST-01160300545280208415245M8<25
LCS-SST-01200370545280208415245M8<25
LCS-SST-01250470575310208445279M8<35
LCS-SST-01315570575310208445279M8<35
LCS-SST-01400720600350220475320M8<40
LCS-SST-01450840600350220475320M8<40
ModelRated PowerKWRated CurrentAOverall dimensionsMounting dimensionsNet weight Kg
H1W1DH2W2d
LCS-SST-011123245160170220140M6<3.5
LCS-SST-011530245160170220140M6<3.5
LCS-SST-0118.537245160170220140M6<3.5
LCS-SST-012245245160170220140M6<3.5
LCS-SST-013060245160170220140M6<3.5
LCS-SST-013775245160170220140M6<3.5
LCS-SST-014590245160170220140M6<3.5
LCS-SST-0155110245160170220140M6<3.5
LCS-SST-0175145545280208415245M8<25
LCS-SST-0190175545280208415245M8<25
LCS-SST-01110210545280208415245M8<25
LCS-SST-01132250545280208415245M8<25
LCS-SST-01160300545280208415245M8<25
LCS-SST-01200370545280208415245M8<25
LCS-SST-01250470575310208445279M8<35
LCS-SST-01315570575310208445279M8<35
LCS-SST-01400720600350220475320M8<40
LCS-SST-01450840600350220475320M8<40
Intelligent Motor Soft Starter 11kW to 450kW

Generator Equipment

LCS-GEN-01

Very Low Frequency High Voltage Generator

Digital Ultrasonic Generator MPPT Solar Charger Controller PWM Solar Charge Controller Wind Solar Hybrid Controller Grid Connected Inverter AC DC Batter Charger PV Combiner Box VLF High Voltage Generator 12 900V DC Contactor Photovoltaic Parts Soft Starter Very Low Frequency High Voltage Generator

Product Description

BVLF (Very Low Frequency) Testers are suitable for testing power cables, transformers, switchgear, rotating machinery and other electrical apparatus. The product combines modern advanced digital variable frequency technology and micro computer control together, therefore, it can realize the full automatic voltage boost, stepdown, measurement and protection as well as the manual intervention in the process of automatic voltage boost. The full electronic design ensures the small size and light weight. The big LCD screen ensures the clear and visual display, and can display the output sinusoidal wave form. The printer outputs test reports. In addition, the product has features as follows:

1. Data of current, voltage, wave form can be directly sampled at high voltage side, so the data is real and accurate.

2. Overvoltage protection: If the output exceeds the set limit of voltage, the instrument will shut down to protect itself, the actuation time is less than 20ms.

3. Overcurrent protection: It is high low voltage dual protection in the design, the accurate shut down protection can be made according to the set value at high voltage side; If the current on low voltage side exceeds the rated current, the instrument will take shut down protection, the actuation time are both less than 20ms.

4. A high voltage output protective resistor is provided in the voltage boost body in the design and this eliminates the need of additional protective resistor connected outside.

Technical parameters

1. Output voltage ratings: 30KV, 40KV, 50KV, 60KV, 70KV, 80kV (peak)

2. Output frequency: 0.1Hz, 0.05Hz, 0.02Hz

3. Measurement accuracy: 3%

4. Positive and negative voltage peak errors: ≤ 3%

5. Voltage wave form distortion: ≤ 5%

6. Use condition: Indoor and outdoor; Temperature: 10C +40C; Humidity: ≤ 85%RH

7. Power: AC50Hz, 220V + 5%

8. Power supply fuse tube: 10A Model Peak voltage Measuring range Weight Purpose BVLF 30 30KV

0.1Hz,≤1.1µF Controller: 4 kg Booster: 25 kg Size: L*W*H 323*174*323 10KV and below voltage cable, generator

0.05Hz,≤2.2µF

0.02Hz,≤5.5µF BVLF 40 40KV

0.1Hz,≤1.1µF Controller: 5 kg Booster: 30 kg Size: L*W*H 357*208*343

13.8KV and below voltage cable, generator

0.05Hz,≤2.2µF

0.02Hz,≤5.5µF BVLF 50 50KV

0.1Hz,≤1.1µF Controller: 6 kg Booster: 45 kg Size: L*W*H 357*210*365

15.75KV and below voltage cable, generator

0.05Hz,≤2.2µF

0.02Hz,≤5.5µF BVLF 60 60KV

0.1Hz,≤1.1µF Controller: 6 kg Booster: 50 kg Size: L*W*H 357*220*370 18KV and below voltage cable, generator

0.05Hz,≤2.2µF

0.02Hz,≤5.5µF BVLF 90 90KV

0.1Hz,≤1.1µF Controller: 8 kg Booster: 90 kg Size: L*W*H 357*240*390 35KV and below voltage cable, generator

ModelPeak voltageMeasuring rangeWeightPurpose
BVLF-3030KV0.1Hz,≤1.1µFController: 4 kg Booster: 25 kg Size: L*W*H 323*174*32310KV and below voltage cable, generator
0.05Hz,≤2.2µF
0.02Hz,≤5.5µF
BVLF-4040KV0.1Hz,≤1.1µFController: 5 kg Booster: 30 kg Size: L*W*H 357*208*34313.8KV and below voltage cable, generator
0.05Hz,≤2.2µF
0.02Hz,≤5.5µF
BVLF-5050KV0.1Hz,≤1.1µFController: 6 kg Booster: 45 kg Size: L*W*H 357*210*36515.75KV and below voltage cable, generator
0.05Hz,≤2.2µF
0.02Hz,≤5.5µF
BVLF-6060KV0.1Hz,≤1.1µFController: 6 kg Booster: 50 kg Size: L*W*H 357*220*37018KV and below voltage cable, generator
0.05Hz,≤2.2µF
0.02Hz,≤5.5µF
BVLF- 9090KV0.1Hz,≤1.1µFController: 8 kg Booster: 90 kg Size: L*W*H 357*240*39035KV and below voltage cable, generator
Very Low Frequency High Voltage Generator Very Low Frequency High Voltage Generator
LCS-GEN-02

Very Low Frequency Cable Testing Set

Digital Ultrasonic Generator MPPT Solar Charger Controller PWM Solar Charge Controller Wind Solar Hybrid Controller Grid Connected Inverter AC DC Batter Charger PV Combiner Box VLF High Voltage Generator 12 900V DC Contactor Photovoltaic Parts Soft Starter Very Low Frequency Cable Testing

Product Description

BVLF (Very Low Frequency) Testers are suitable for testing power cables, transformers, switchgear, rotating machinery and other electrical apparatus. The product combines modern advanced digital variable frequency technology and micro computer control together, therefore, it can realize the full automatic voltage boost, stepdown, measurement and protection as well as the manual intervention in the process of automatic voltage boost. The full electronic design ensures the small size and light weight. The big LCD screen ensures the clear and visual display, and can display the output sinusoidal wave form. The printer outputs test reports. In addition, the product has features as follows:

1. Data of current, voltage, wave form can be directly sampled at high voltage side, so the data is real and accurate.

2. Overvoltage protection: If the output exceeds the set limit of voltage, the instrument will shut down to protect itself, the actuation time is less than 20ms.

3. Overcurrent protection: It is high low voltage dual protection in the design, the accurate shut down protection can be made according to the set value at high voltage side; If the current on low voltage side exceeds the rated current, the instrument will take shut down protection, the actuation time are both less than 20ms.

4. A high voltage output protective resistor is provided in the voltage boost body in the design and this eliminates the need of additional protective resistor connected outside.

Technical parameters

1. Output voltage ratings: 30KV, 40KV, 50KV, 60KV, 70KV, 80kV (peak)

2. Output frequency: 0.1Hz, 0.05Hz, 0.02Hz

3. Measurement accuracy: 3%

4. Positive and negative voltage peak errors: ≤ 3%

5. Voltage wave form distortion: ≤ 5%

6. Use condition: Indoor and outdoor; Temperature: 10C +40C; Humidity: ≤ 85%RH

7. Power: AC50Hz/60Hz, 220V + 5%

8. Power supply fuse tube: 10A Model Peak voltage Measuring range Weight Purpose BVLF 30 30KV

0.1Hz,≤1.1µF Controller: 4 kg Booster: 25 kg Size: L*W*H 323*174*323 10KV and below voltage cable, generator

0.05Hz,≤2.2µF

0.02Hz,≤5.5µF BVLF 40 40KV

0.1Hz,≤1.1µF Controller: 5 kg Booster: 30 kg Size: L*W*H 357*208*343

13.8KV and below voltage cable, generator

0.05Hz,≤2.2µF

0.02Hz,≤5.5µF BVLF 50 50KV

0.1Hz,≤1.1µF Controller: 6 kg Booster: 45 kg Size: L*W*H 357*210*365

15.75KV and below voltage cable, generator

0.05Hz,≤2.2µF

0.02Hz,≤5.5µF BVLF 60 60KV

0.1Hz,≤1.1µF Controller: 6 kg Booster: 50 kg Size: L*W*H 357*220*370 18KV and below voltage cable, generator

0.05Hz,≤2.2µF

0.02Hz,≤5.5µF BVLF 90 90KV

0.1Hz,≤1.1µF Controller: 8 kg Booster: 90 kg Size: L*W*H 357*240*390 35KV and below voltage cable, generator

ModelPeak voltageMeasuring rangeWeightPurpose
BVLF-3030KV0.1Hz,≤1.1µFController: 4 kg Booster: 25 kg Size: L*W*H 323*174*32310KV and below voltage cable, generator
0.05Hz,≤2.2µF
0.02Hz,≤5.5µF
BVLF-4040KV0.1Hz,≤1.1µFController: 5 kg Booster: 30 kg Size: L*W*H 357*208*34313.8KV and below voltage cable, generator
0.05Hz,≤2.2µF
0.02Hz,≤5.5µF
BVLF-5050KV0.1Hz,≤1.1µFController: 6 kg Booster: 45 kg Size: L*W*H 357*210*36515.75KV and below voltage cable, generator
0.05Hz,≤2.2µF
0.02Hz,≤5.5µF
BVLF-6060KV0.1Hz,≤1.1µFController: 6 kg Booster: 50 kg Size: L*W*H 357*220*37018KV and below voltage cable, generator
0.05Hz,≤2.2µF
0.02Hz,≤5.5µF
BVLF- 9090KV0.1Hz,≤1.1µFController: 8 kg Booster: 90 kg Size: L*W*H 357*240*39035KV and below voltage cable, generator
Very Low Frequency Cable Testing Set Very Low Frequency Cable Testing Set
LCS-GEN-03

Very Low Frequency Insulation Testing Set

Digital Ultrasonic Generator MPPT Solar Charger Controller PWM Solar Charge Controller Wind Solar Hybrid Controller Grid Connected Inverter AC DC Batter Charger PV Combiner Box VLF High Voltage Generator 12 900V DC Contactor Photovoltaic Parts Soft Starter Very Low Frequency insulation testing

Product Description

BVLF (Very Low Frequency) Testers are suitable for testing power cables, transformers, switchgear, rotating machinery and other electrical apparatus. The product combines modern advanced digital variable frequency technology and micro computer control together, therefore, it can realize the full automatic voltage boost, stepdown, measurement and protection as well as the manual intervention in the process of automatic voltage boost. The full electronic design ensures the small size and light weight. The big LCD screen ensures the clear and visual display, and can display the output sinusoidal wave form. The printer outputs test reports. In addition, the product has features as follows:

1. Data of current, voltage, wave form can be directly sampled at high voltage side, so the data is real and accurate.

2. Overvoltage protection: If the output exceeds the set limit of voltage, the instrument will shut down to protect itself, the actuation time is less than 20ms.

3. Overcurrent protection: It is high low voltage dual protection in the design, the accurate shut down protection can be made according to the set value at high voltage side; If the current on low voltage side exceeds the rated current, the instrument will take shut down protection, the actuation time are both less than 20ms.

4. A high voltage output protective resistor is provided in the voltage boost body in the design and this eliminates the need of additional protective resistor connected outside.

Technical parameters

1. Output voltage ratings: 30KV, 40KV, 50KV, 60KV, 70KV, 80kV (peak)

2. Output frequency: 0.1Hz, 0.05Hz, 0.02Hz

3. Measurement accuracy: 3%

4. Positive and negative voltage peak errors: ≤ 3%

5. Voltage wave form distortion: ≤ 5%

6. Use condition: Indoor and outdoor; Temperature: 10C +40C; Humidity: ≤ 85%RH

7. Power: AC50Hz/60Hz, 220V + 5%

8. Power supply fuse tube: 10A Model Peak voltage Measuring range Weight Purpose BVLF 30 30KV

0.1Hz,≤1.1µF Controller: 4 kg Booster: 25 kg Size: L*W*H 323*174*323 10KV and below voltage cable, generator

0.05Hz,≤2.2µF

0.02Hz,≤5.5µF BVLF 40 40KV

0.1Hz,≤1.1µF Controller: 5 kg Booster: 30 kg Size: L*W*H 357*208*343

13.8KV and below voltage cable, generator

0.05Hz,≤2.2µF

0.02Hz,≤5.5µF BVLF 50 50KV

0.1Hz,≤1.1µF Controller: 6 kg Booster: 45 kg Size: L*W*H 357*210*365

15.75KV and below voltage cable, generator

0.05Hz,≤2.2µF

0.02Hz,≤5.5µF BVLF 60 60KV

0.1Hz,≤1.1µF Controller: 6 kg Booster: 50 kg Size: L*W*H 357*220*370 18KV and below voltage cable, generator

0.05Hz,≤2.2µF

0.02Hz,≤5.5µF BVLF 90 90KV

0.1Hz,≤1.1µF Controller: 8 kg Booster: 90 kg Size: L*W*H 357*240*390 35KV and below voltage cable, generator

ModelPeak voltageMeasuring rangeWeightPurpose
BVLF-3030KV0.1Hz,≤1.1µFController: 4 kg Booster: 25 kg Size: L*W*H 323*174*32310KV and below voltage cable, generator
0.05Hz,≤2.2µF
0.02Hz,≤5.5µF
BVLF-4040KV0.1Hz,≤1.1µFController: 5 kg Booster: 30 kg Size: L*W*H 357*208*34313.8KV and below voltage cable, generator
0.05Hz,≤2.2µF
0.02Hz,≤5.5µF
BVLF-5050KV0.1Hz,≤1.1µFController: 6 kg Booster: 45 kg Size: L*W*H 357*210*36515.75KV and below voltage cable, generator
0.05Hz,≤2.2µF
0.02Hz,≤5.5µF
BVLF-6060KV0.1Hz,≤1.1µFController: 6 kg Booster: 50 kg Size: L*W*H 357*220*37018KV and below voltage cable, generator
0.05Hz,≤2.2µF
0.02Hz,≤5.5µF
BVLF- 9090KV0.1Hz,≤1.1µFController: 8 kg Booster: 90 kg Size: L*W*H 357*240*39035KV and below voltage cable, generator
Very Low Frequency Insulation Testing Set
LCS-GEN-04

Very Low Frequency Generator with Dielectric Loss Testing

Digital Ultrasonic Generator MPPT Solar Charger Controller PWM Solar Charge Controller Wind Solar Hybrid Controller Grid Connected Inverter AC DC Batter Charger PV Combiner Box VLF High Voltage Generator 12 900V DC Contactor Photovoltaic Parts Soft Starter VLF with dielectric loss testing

Product Description

BVLF (Very Low Frequency) Testers are suitable for testing power cables, transformers, switchgear, rotating machinery and other electrical apparatus. The product combines modern advanced digital variable frequency technology and micro computer control together, therefore, it can realize the full automatic voltage boost, stepdown, measurement and protection as well as the manual intervention in the process of automatic voltage boost. The full electronic design ensures the small size and light weight. The big LCD screen ensures the clear and visual display, and can display the output sinusoidal wave form. The printer outputs test reports. In addition, the product has features as follows:

1. Data of current, voltage, wave form can be directly sampled at high voltage side, so the data is real and accurate.

2. Overvoltage protection: If the output exceeds the set limit of voltage, the instrument will shut down to protect itself, the actuation time is less than 20ms.

3. Overcurrent protection: It is high low voltage dual protection in the design, the accurate shut down protection can be made according to the set value at high voltage side; If the current on low voltage side exceeds the rated current, the instrument will take shut down protection, the actuation time are both less than 20ms.

4. A high voltage output protective resistor is provided in the voltage boost body in the design and this eliminates the need of additional protective resistor connected outside.

Technical parameters

1. Voltage (peak) 0 80kv, sensitivity: 0.1kV, accuracy: 1 %

2. Waveform

ultra low frequency sine wave, DC voltage, positive and negative voltage peak error: ≤ 3%, voltage waveform distortion: ≤ 1%

3. Frequency range: 0.1 Hz 0.05 Hz 0.02 Hz Load range (ultra low frequency test): 10nF 10μF

4. Current

Measurement range: 0 70 mA, sensitivity: 1 μA, accuracy: 1 %

5. Dielectric loss. Ultra low frequency sine wave voltage range: 1 80 kVrms Load range: 50 nF 5 μF Resolution: not less than 1x10 6 Accuracy: not less than 1x10 3 Measurement range: 1x10 3 21000x10 3 Dielectric measurement frequency: 0.1Hz Capacitance range: 50nF 5μF Resistance range: 30MΩ 10GΩ

Volume

48cm*28cm*58cm Weight: 45kg

6. Operating conditions: indoor, outdoor; temperature: 10 ℃~ +40 ℃ ; humidity: ≤85%RH

7. Power supply

frequency 50Hz,60hz, voltage 100v 260V±5%.

8. usb communication port.

9. Use conditions: indoor, outdoor; temperature: 10 ℃~ +40 ℃ ; humidity: ≤85%RH

10.Power supply fuse: see table 3

11. Power supply: voltage 220V±5%, 50±5Hz

12. Principle of dielectric loss test Electrical model of cable insulation Good insulation resistance tends to infinity; capacitive impedance is related to cable characteristics and length; resistive current is very small and in phase with the voltage; capacitive current has a fixed value and is 90° behind the voltage in phase l The higher the resistive current, the lower the insulation capacity l The higher the resistive current, the higher the dissipation angle δ l The larger the angle of dissipation, the larger the tangent value l The degree of insulation ageing can be determined by measuring the tangent of the dissipation angle

Very Low Frequency Generator with Dielectric Loss Testing Very Low Frequency Generator with Dielectric Loss Testing Very Low Frequency Generator with Dielectric Loss Testing
LCS-GEN-05

50Hz and 60Hz Universal Very Low Frequency High Voltage Generator

Very low frequency insulation withstand voltage testing is an alternative to power frequency withstand voltage testing. When power frequency testing is carried out on large and medium generators, motors, power cables and similar test objects, their insulation layers present large capacitance, so a very large test transformer or resonant transformer is needed. Such equipment is bulky, costly and inconvenient. Lowering the test frequency lowers the test power supply capacity. Using 0.1Hz very low frequency withstand voltage testing in place of power frequency testing gives the same equivalence with much smaller volume and weight, a theoretical capacity of about one five hundredth of power frequency, and simple operation.

Features:

1. Large touch screen, 7 inch touch screen with ARM7 microcontroller.

2. Digital variable frequency technology with microcomputer control, fully automatic voltage boost, voltage reduction, measurement and protection.

3. Simple wiring and simple operation.

4. Full protection functions including over voltage protection and high and low voltage side over current protection, with action time of 10ms or less.

5. The controller and high voltage generator connect at low voltage with photoelectric control for safe and reliable use.

6. High and low voltage closed loop negative feedback control circuit, with no capacitive rise effect on the output.

7. Capacitive touch screen, LCD display, automatic storage and automatic printing.

8. Wide test range with 0.1Hz, 0.05Hz and 0.02Hz frequency selection.

9. Small volume and light weight, well suited to field work.

10. Bilingual switching function with high voltage electronic switch polarity switching.

11. High speed AD acquisition circuit with USB background management software.

12. Longer service life and lower failure rate.

13. Universal 220VAC 50Hz and 60Hz input.

Technical parameters:

Output frequency: 0.1Hz, 0.05Hz, 0.02Hz

Load capacity: 0.1Hz at 1.1uF, 0.05Hz at 2.2uF, 0.02Hz at 5.5uF

Measurement accuracy: 3 percent

Positive and negative voltage peak error: 3 percent or less

Voltage waveform distortion: 5 percent or less

Conditions of use: indoors and outdoors, temperature minus 10 to plus 40 degrees C, humidity 85 percent RH or less

Power supply: 110KV to 260KV (plus or minus 5 percent) as printed on the source page

50Hz and 60Hz Universal Very Low Frequency High Voltage Generator

Request a Quote

Tell us the load, the input you have and the output you need. We will match the right charger, converter or starter and send one clear quotation for the full package.

Email Your Project Details Call (945) 227-9608