Lifestyle Construction and Supplies logo
Lifestyle Construction & Supplies
Building Stronger. Supplying Smarter.

Polycarbonate by Lifestyle Construction & Supplies

Heat Control Polycarbonate Sheets

Reference LCS-PC-104

Heat control polycarbonate sheets in light grey and dark grey shades for projects that need solar control with daylight. Light shade is listed at 5, 6, 8 or 10 mm with lengths up to 6 m; dark shade at 1.8, 2, 2.5 or 3 mm.

Request solar control polycarbonate sheets cut to size for canopies, carports and covered walkways, or discuss a drawing led equipment panel. The recorded grey product range distinguishes light shades at 5 to 10 mm and dark shades at 1.8 to 3 mm. Define the daylight, viewing and thermal objective so the proposed configuration can be reviewed against the right evidence.

Grey sheet sample shown at an angle

Product reference image supplied with the heat control sheet material. Appearance is illustrative; optical and thermal performance require grade specific data.

★ CORE PRODUCT · LCS-PC-104

Supply configuration and selection limits

Grey sheet sample shown at an angle

Grey polycarbonate sheet sample; a photograph cannot establish solar or UV performance.

Heat control polycarbonate sheets

Recorded enquiry ranges: light shade grey PC at 5 to 10 mm; dark shade grey PC at 1.8 to 3 mm. The quotation must identify the chosen grade, shade, sheet format and finished quantity.

For purchasing engineers, product engineers and equipment integrators: begin with a drawing and acceptance criteria. For owners and end users: describe the installation, environment and maintenance expectations.

Material and finish

Polycarbonate with a proprietary heat control formulation and coextruded UV protection, as described in the product data record. Standard colour: grey; light and dark shades require sample approval.

Thickness and length

Light shade range: 5 to 10 mm, with custom lengths up to 6 m. Dark shade range: 1.8 to 3 mm. Send the required width and length for each part. Confirm available sheet format, cutting allowance, tolerances and packing rather than assuming every gauge and size combination is stocked.

Optical and solar performance requirements

Specify the optical or solar property you need, the acceptance limit and the intended installation. Request a report identifying the grade, shade, thickness, test method and measurement conditions. A heat control description alone does not establish solar energy transmission, a U value or the temperature of the completed space. For a 2.5 mm sample, ask for the product code, exact grey shade and sample ID. Request visible transmission and haze with their method, then obtain the method and wavelength range for near infrared transmission and total solar transmission. Confirm how any thermal barrier percentage was calculated before comparing figures across offers.

Weathering and service conditions

Describe sun exposure, climate, exposed faces, cleaning and maintenance access. Ask for the weathering evidence applicable to the offered grade and configuration, and confirm any warranty terms in writing. A short appearance test does not establish an outdoor replacement interval.

Application route

sunrooms, carports and covered walkways. Compare shade, daylight, heat gain, ventilation and roof geometry. Material selection does not replace complete roof or frame assessment.

Cut to size quotation inputs

Provide application, shade reference, required thickness, finished dimensions, quantity per size, frame details, destination and target delivery date. State the optical or solar metric the project uses. Review documentation scope and sample and supply terms when agreeing acceptance.

Select a light grey or dark grey sheet for quotation

Catalogue shadeListed gauges and formatOrder specific confirmation
Light grey5, 6, 8 or 10 mm. The catalogue lists lengths up to 6 m.Consult Lifestyle for current size combinations, available widths, cut allowance, exposed face, packing and shade sample.
Dark grey1.8, 2, 2.5 or 3 mm. Give the required cut lengths and width for each line.Consult Lifestyle for the delivery format and available lengths. For a long length enquiry request the handling limits, package dimensions and unloading requirements.

References: Outdoor PC Heat Control Panels 260521, pp. 4 to 5. The internal data table describes a light grey appearance and lists results for a 2.5 mm specimen. Consult Lifestyle for its grade, shade code and relationship to the quoted series. Ask for a labelled sample and the version of the technical data sheet applicable to your order.

Consult Lifestyle for the definition and test method behind any thermal barrier figure, including the specimen and wavelength range. Request visible transmission, haze, near infrared transmission, total solar transmission and UV data separately where required. For outdoor use, request grade specific weathering evidence and written warranty terms.

Send the application, site exposure, desired daylight, panel dimensions, quantity, destination and timetable. Indicate whether you require a shade sample, a cut or formed first article, or bulk sheets.

02 / BEFORE YOU ORDER

Review the product in context.

The material, fabrication route and installed system need a consistent specification.

Define the daylight requirement

Assess the whole covered space

Orientation, roof area, ventilation, enclosure and local climate affect comfort. Use the canopy selection checklist to define these conditions before comparing light transmission and solar performance data.

Agree the installation interface

Confirm the support arrangement, relevant design loads, exposed faces and compatible system details. The sheet choice alone does not verify a roof structure.

03 / SAMPLES & SUPPLY

Plan material samples, first articles and bulk supply

Identify your procurement stage in the enquiry form. Keep material evaluation, finished part approval and the repeat order specification connected through an agreed grade and drawing revision.

1. Material sample

Send the application, intended shade, thickness and viewing/daylight requirement. Agree an identified sample for appearance and any required test specimen. Record which optical or thermal questions need measured data; a small colour sample alone cannot predict the installed temperature.

2. Machined or formed first article

Send the drawing revision, finished size, holes, edge finish and frame/seal interfaces. Review the proposed process for the selected material. Agree tolerances by drawing, process and technical agreement, and define fit, appearance and any application specific checks before making the sample.

3. Bulk supply

Reference the approved grade, shade sample and drawing. State quantity per size, repeat demand, packing, protective film and identification needs, delivery destination and required date. Confirm MOQ and schedule in the quotation; agree inspection and review of substitutions before production.

Compare the quoted scope

Compare full sheets, cut panels and finished parts on the same delivered quantity. Identify material, processing, sample/setup charges, inspection, packing and freight separately where relevant. Request the grade specific TDS and applicable reports, including thickness, colour and test conditions.

Select heat control polycarbonate for the actual installation

Separate shade, solar heat gain and insulation

For a canopy or covered walkway, state the daylight and shading objective, orientation, roof area, ventilation and site climate. For an equipment cover or transparent door, define whether the concern is incoming solar energy, heat transfer across the component or a specific equipment temperature. These are different measurement tasks. A darker appearance does not replace a matched optical or solar test.

Define the panel and delivery format

For equipment panels, include the clear viewing area, finished thickness and size, holes, edge conditions, frame and seals, temperature on each side, condensation and cleaning procedure. State whether you want full sheets, rectangular cut panels or drawing led parts. Ask the quotation to identify the delivery format, usable dimensions and handling/packing requirements. Long length supply and unusual width/gauge combinations need order specific confirmation.

Compare reports for the same configuration

Ask each supplier to identify the property measured, method, units, specimen thickness, shade and exposed face. Compare light transmission separately from solar measurements and whole component thermal performance. A demonstration photograph does not establish a U value or whole door energy rating. Use the thermal data comparison guide and the industrial panel guide to define the evidence needed for your sample and order.

Before requesting a quote

Is the heat control percentage the same as light transmission?

No. Ask how each value was measured and what it describes. Compare like for like reports for the proposed material.

Can I select the colour from a screen image?

Use a screen image only as a starting point. Agree an identified sample and grade before placing a colour critical order.

Request a Quote

Send your application, sheet thickness and dimensions, colour, quantity, destination and target date. Our team will reply with a recommendation and a clear quotation.

Phone: (945) 227-9608
Email: contact@lifestyleconstructionsupplies.com
Website: lifestyleconstructionsupplies.com
Address: 811 East Plano Pkwy Ste 117, Plano, TX 75074

Email Your Project Details