Polycarbonate by Lifestyle Construction & Supplies
Snap Lock Polycarbonate Facade Panels
Reference LCS-PC-108
Snap lock hollow polycarbonate panels for translucent facades, daylighting walls and interior partitions. The catalogue lists a 500 mm panel width and 30, 40 or 50 mm thickness, with mating male and female edges.
Specify snap lock hollow polycarbonate panels for translucent facades, daylighting walls and interior partitions. The Lifestyle catalogue lists 500 mm panel width and 30, 40 or 50 mm thickness, with mating male/female edges. This is a separate panel family from the 600 / 1040 mm U lock roof panel range.
Snap lock facade panel specification
| Field | Catalogue reference | Ordering detail |
|---|---|---|
| Material | Hollow polycarbonate; virgin material listed | Confirm resin, wall section and UV construction |
| Thickness | 30 / 40 / 50 mm | Select the exact section and mass |
| Panel width | 500 mm | Confirm nominal versus effective cover width on drawing |
| Length | Not specified | Provide elevation height and shipping constraints |
| Colours | Clear, opal, blue, green, yellow, orange | Approve appearance in daylight and, if relevant, backlighting |
| Listed applications | Exterior daylighting walls, interior partitions and entrance cladding | Obtain a system specific fixing and perimeter detail |
Facade panel procurement: qualify the assembly
The brochure describes protrusions and grooves along the panel edges that engage with the adjacent panel. The edge connection is only one part of the building assembly.
For a polycarbonate facade panel system quotation, provide elevation drawings and mark panel modules, joints, corners, openings and interfaces with the adjacent wall. State whether the panel is an external facade, an internal partition or another construction element. Include the support layout, sill and head conditions, compatible profiles, retainers and fixing schedule for the chosen section.
Ask the project designer to identify the applicable structural, thermal, water management and fire requirements. Request evidence for the proposed panel and profile assembly, including fixing arrangements and interfaces. Sheet light transmission or a material fire result does not independently approve a building envelope. The catalogue provides no verified facade system load table or fire approval for this range. Solid PC UL 94 results elsewhere in this range must not be transferred to these cellular panels. No universal unsupported span or fastener free building installation is implied.
Include expected panel movement, replacement access, exposed faces, surface appearance and sample approval in the enquiry. Agree whether profiles, seals, fasteners, drawings and installation support are included in the price. Keep roof only interlocking panels distinct from the proposed facade system.
Use the thermal performance guide for comparison boundaries and Quality & Documentation for report requests.
Facade and partition catalogue references
| Country / application | Catalogue panel | Reported area |
|---|---|---|
| China · sports building facade | 40 mm snap lock PC | 12,000 m² |
| China · interior partition | 30 mm snap lock PC | 5,500 m² |
| China · interior wall feature | 50 mm snap lock PC | 6,500 m² |
The listed sizes describe those catalogue records; they are not a specification for your building. Customer names are withheld. For translucent wall panels, approve the visual privacy and light distribution with a representative sample under the actual lighting conditions.
Snap lock versus U lock: request the correct system
Use this page for the 500 mm snap lock facade and partition family. Use the U lock roof panel page for the confirmed LCS-PC-106 roof supply scope. The brochure’s general snap lock paragraph also mentions roofs; roofing suitability for this 500 mm family requires a specific design review and must not be inferred from the facade table.
Prepare a snap lock facade panel schedule by elevation
For translucent snap lock polycarbonate facade panels, label each wall bay on the elevation. Give finished opening width and height, daylight or privacy goal, colour, joint direction, return corners and head/sill details. Mark doors, signage or services that interrupt a run.
The architectural catalogue lists a 500 mm panel width and 30, 40 and 50 mm thickness options. Ask the supplier to show net coverage, panel count and the width of the last cut panel on the elevation. Confirm the colour and thickness combination on the quoted section drawing.
Confirm the snap lock section before releasing a wall bay
Architectural catalogue spread 9 lists 30, 40 and 50 mm panels with a listed width of 500 mm. Mark the required thickness and finish on each elevation. Request a cross section showing the two engaged panel edges, dimensioned net cover, supports and the head, sill and closing details.
Consult Lifestyle for the current drawing revision, producible length and colour, connector and trim list, and project specific fixing details. Ask for a jointed colour sample and an itemised quotation by elevation. Give the desired installation sequence and name the party supplying the subframe.
Send panel elevation, height, width, chosen thickness and colour, total area or piece count, project country, support spacing, design wind criteria, indoor/outdoor exposure, fire requirements and construction programme. Ask which perimeter profiles, seals and fixings are included, and agree effective coverage before calculating quantities.
For industrial buyers and building envelope integrators, identify interfaces with doors, vents, lighting or equipment. Where a translucent partition surrounds sensors, confirm the required optical path rather than assuming a wall panel is a suitable sensor window.
Facade and partition application guidance · Flat multiwall sheets · Samples and supply terms · Report scope and quality documentation
Request a Quote
Send your application, sheet thickness and dimensions, colour, quantity, destination and target date. Our team will reply with a recommendation and a clear quotation.
Phone: (945) 227-9608
Email: contact@lifestyleconstructionsupplies.com
Website: lifestyleconstructionsupplies.com
Address: 811 East Plano Pkwy Ste 117, Plano, TX 75074