Polycarbonate by Lifestyle Construction & Supplies
Interlocking Polycarbonate Roof Panels
Reference LCS-PC-106
Interlocking polycarbonate roof panels use a U lock connection, with an 8 to 40 mm enquiry range and nominal widths of 600 or 1040 mm. Start with the system section and effective coverage for roof daylighting or covered walkways.
Interlocking polycarbonate roof panels use a U lock connection, with an 8 to 40 mm enquiry range and nominal widths of 600 or 1040 mm. Start with the system section and effective coverage for roof daylighting or covered walkways. Coordinate the roof panels, joints, supports and accessories with the roofing system buying guide.
Joint detail sample. Confirm the section and connection drawing for the selected panel configuration.
★ CORE PRODUCT · LCS-PC-106
Supply configuration and selection limits
Coloured interlocking panels showing raised joining edges. Confirm the complete roof system connection details.
U lock polycarbonate roof panels
Roof only U lock panels: 8 to 40 mm, nominal widths 600 or 1040 mm.
For purchasing engineers, product engineers and equipment integrators: begin with a drawing and acceptance criteria. For owners and end users: describe the installation, environment and maintenance expectations.
Panel family
Interlocking polycarbonate roof panels, also described as U lock sheets. Raised joining features support system assembly; aesthetic appearance and installation convenience depend on the complete roof specification.
Dimensions and colours
Thickness enquiry range: 8 to 40 mm. Nominal panel widths: 600 or 1040 mm. Confirm effective coverage, length, joint geometry, compatible profiles and thickness availability. Colours can be customised subject to quotation and sample approval.
Roof only use boundary
The product data limits LCS-PC-106 to roofing. Do not assume suitability for vertical facades or other non roof uses. Check support spacing, wind/snow loads, slope, thermal movement, sealing and connection details for the specific system.
Application route
sunroom, canopy and walkway roofs. For the broader roof design brief, see roof daylighting selection. Product dimensions do not establish an allowable span.
US bronze interlocking roof panel case illustrates a documented supply project, not a universal design approval. Obtain quality documentation and report scope for the ordered panel; do not transfer LCS-PC-101 solid sheet test results to LCS-PC-106.
RFQ checklist
Send roof plan, slope, supports, panel length, desired colour, wind/snow criteria, fire requirements, quantity and destination. Confirm packaging, compatible accessories and sample and supply terms.
U lock roof catalogue: sizes and connection detail
Catalogue U lock joint section; request the production drawing and compatible connector specification.
8, 10, 12, 16, 18, 20, 25, 30, 35 and 40 mm; widths 600 or 1040 mm. Request the exact section and effective cover width.
Clear, opal, blue, green, yellow and orange are listed. Confirm UV construction, section, wall count, connector and finished length for the order.
The brochure lists a 12 mm U lock daylighting roof (6,500 m²), an 18 mm platform canopy (5,000 m²), and a 16 mm stadium roof reference. The stadium area is omitted because the Chinese and English entries disagree.
The catalogue table also mentions wall applications, while the confirmed LCS-PC-106 product data limits this family to roofing. The roof only scope remains in force. For a facade or partition enquiry, use the separate 500 mm snap lock family and obtain a system specific review. A joint image does not guarantee watertightness or wind resistance.
Quote U lock roof panels by net cover and joint kit
For interlocking polycarbonate roof panels, submit the roof run, slope direction, support layout and the allowable locations of joints and cut edges. Ask for a section drawing that identifies panel edges, the separate connector, effective cover width and the fixing interface. The listed 600 and 1040 mm widths need a drawing based coverage check.
Use the confirmed net coverage to produce a panel schedule for each run. Allow separately for perimeter cuts, closures, caps, flashings, fixings and replacement pieces. State which parts the supplier will pack together and which interfaces the installing contractor will provide.
A small joint assembly can resolve profile compatibility before a bulk order. For vertical wall cladding, start with snap lock facade panels and the facade procurement guide.
Confirm the U lock connector and roof takeoff
Architectural catalogue spread 10 lists 600 mm and 1,040 mm widths for this panel family. On the proposed roof section, mark the side joint, panel engagement and cover between repeated joints. Give the run length, edge conditions and intended thickness for each roof zone.
Consult Lifestyle for the exact width and gauge combination, installed cover, connector, caps, closures, fixings and current detail drawing. Ask which items the supplier will pack and which items the installer must source. Submit project loads and support spacing to the responsible roof designer before ordering.
02 / BEFORE YOU ORDER
Review the product in context.
The material, fabrication route and installed system need a consistent specification.
Review the section and connection
Provide the roof layout, dimensions, support spacing and relevant wind and snow loads. Ask for the panel section and joint details needed by the project designer.
Make the scope of supply explicit
Identify which panels, connectors, perimeter details, fasteners and other components are included. Do not infer a complete engineered roof package from a panel quotation.
Confirm handling and site work
Agree packing, panel identification, installation instructions and any cutting permitted on site. Review the proposed installation sequence before finalising the order.
03 / SAMPLES & SUPPLY
Make the quotation specific.
Include the grade, dimensions, colour, quantity, intended use and destination. Identify any fixed requirement and any point needing selection support.
Samples
Agree whether the sample is for colour, surface, dimensional fit or laboratory testing. Record its identity and the acceptance purpose.
MOQ and timing
Review sample and shipping arrangements, then request a system specific quantity and production schedule. Base panel quantities on effective coverage and the approved layout, not nominal width alone.
Packing and processing
Specify protective film, cutting or fabrication, labels and packing requirements. Confirm any tolerances against the drawing.
Technical documentation
Request the grade specific TDS and relevant report scope. Identify the specimen thickness, method and conditions behind a performance value.
Before requesting a quote
Are these panels suitable for wall cladding?
The current confirmed product scope is roofing. Discuss any other use separately rather than assuming compatibility.
Can the nominal width be used for the coverage calculation?
Use the effective coverage dimension from the chosen system drawing, including joints and perimeter requirements.
Request a Quote
Send your application, sheet thickness and dimensions, colour, quantity, destination and target date. Our team will reply with a recommendation and a clear quotation.
Phone: (945) 227-9608
Email: contact@lifestyleconstructionsupplies.com
Website: lifestyleconstructionsupplies.com
Address: 811 East Plano Pkwy Ste 117, Plano, TX 75074
